Results for: moldova
Filters
CMC Quick search Filters close;
CMC Area
To filter, either use the tick boxes or click on the underscored item
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Moldova, Republic of, NMI (MD) (The National Metrology Institute of the Republic of Moldova)
Ionizing radiation
Kerma/rate
,
Protection level ionisation chamber
: 1.00E-6 Gy/h to 1.00E-3 Gy/h
Relative expanded uncertainty 3.5 %
Calibration against secondary standard ionisation chamber in reference field in air
Cs-137, ISO 4037-1
Reference standard : Secondary standard ionization chamber PTW 32002
Source of traceability : IAEA
Approved on 15 November 2016
Institute service identifier : COO-RAD-NMI-1001
CMC ID :
EURAMET-RI-MD-00000H2C-1
Ionizing radiation
Kerma/rate
,
Dosemeter or ionization chamber for diagnostic radiology
: 0.036 Gy/h to 6 Gy/h
Relative expanded uncertainty 3.8 %
Calibration against secondary standard ionization chamber
X-ray, 10 kV to 50 kV, RQR3
Reference standard : Secondary standard ionization chamber Exradin A3
Source of traceability : IAEA
Approved on 01 June 2024
Institute service identifier : EUR-RAD-NMI-1007
CMC ID :
EURAMET-RI-MD-00000PL8-1
Ionizing radiation
Kerma/rate
,
Protection level dosemeter or ionization chamber
: 3.6 mGy/h to 430 mGy/h
Relative expanded uncertainty 2.9 %
Calibration against secondary standard ionization chamber
X-ray, 10 kV to 50 kV, N40 ISO4037
Reference standard : Secondary standard ionizing chamber PTW32002
Source of traceability : IAEA
Approved on 01 June 2024
Institute service identifier : EUR-RAD-NMI-1005
CMC ID :
EURAMET-RI-MD-00000PL6-1
Ionizing radiation
Ambient dose equivalent/rate
,
Protection level ionisation chamber and dosimeter
: 1.00E-6 Sv/h to 0.1 Sv/h
Relative expanded uncertainty 4.5 %
Calibration against secondary standard ionisation chamber in reference field in air
Cs-137, Cs-137, 740 GBq
Reference standard : Secondary standard ionization chamber PTW 32002
Source of traceability : IAEA
Approved on 31 May 2024
Institute service identifier : EUR-RAD-NMI-1003
CMC ID :
EURAMET-RI-MD-00000P6F-1
Ionizing radiation
Ambient dose equivalent/rate
,
Protection level dosemeter or ionization chamber
: 0.1 mSv/h to 580 mSv/h
Relative expanded uncertainty 4.9 %
Calibration against secondary standard ionization chamber
X-ray, 50 kV to 300 kV, N60-N200 ISO4037
Reference standard : Secondary standard ionizing chamber PTW32002
Source of traceability : IAEA
Approved on 31 May 2024
Institute service identifier : EUR-RAD-NMI-1004
CMC ID :
EURAMET-RI-MD-00000PKS-1
Ionizing radiation
Kerma/rate
,
Dosemeter or ionization chamber for diagnostic radiology
: 0.06 Gy/h to 21 Gy/h
Relative expanded uncertainty 3.8 %
Calibration against secondary standard ionization chamber
X-ray, 50 kV to 300 kV, RQR4-RQR10
Reference standard : Secondary standard ionization chamber Exradin A3
Source of traceability : IAEA
Approved on 31 May 2024
Institute service identifier : EUR-RAD-NMI-1008
CMC ID :
EURAMET-RI-MD-00000PL9-1
Ionizing radiation
Kerma/rate
,
Protection level ionisation chamber
: 1.00E-3 Gy/h to 0.2 Gy/h
Relative expanded uncertainty 1.8 %
Calibration against secondary standard ionisation chamber in reference field in air
Cs-137, ISO 4037-1
Reference standard : Secondary standard ionization chamber PTW 32002
Source of traceability : IAEA
Approved on 15 November 2016
Institute service identifier : COO-RAD-NMI-1002
CMC ID :
EURAMET-RI-MD-00000H2D-1
Ionizing radiation
Kerma/rate
,
Protection level dosemeter or ionization chamber
: 0.5 mGy/h to 360 mGy/h
Relative expanded uncertainty 2.9 %
Calibration against secondary standard ionization chamber
X-ray, 50 kV to 300 kV, N60-N200 ISO4037
Reference standard : Secondary standard ionizing chamber PTW32002
Source of traceability : IAEA
Approved on 31 May 2024
Institute service identifier : EUR-RAD-NMI-1006
CMC ID :
EURAMET-RI-MD-00000PL7-1