Results for: moldova
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
8 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Moldova, Republic of, NMI (MD) (The National Metrology Institute of the Republic of Moldova)
Ionizing radiation
Kerma/rate , Protection level ionisation chamber : 1.00E-6 Gy/h to 1.00E-3 Gy/h
Relative expanded uncertainty 3.5 %
Calibration against secondary standard ionisation chamber in reference field in air
Cs-137, ISO 4037-1
Reference standard : Secondary standard ionization chamber PTW 32002
Source of traceability : IAEA
Approved on 15 November 2016
Institute service identifier : COO-RAD-NMI-1001
CMC ID : EURAMET-RI-MD-00000H2C-1
 
Ionizing radiation
Kerma/rate , Dosemeter or ionization chamber for diagnostic radiology : 0.036 Gy/h to 6 Gy/h
Relative expanded uncertainty 3.8 %
Calibration against secondary standard ionization chamber
X-ray, 10 kV to 50 kV, RQR3
Reference standard : Secondary standard ionization chamber Exradin A3
Source of traceability : IAEA
Approved on 01 June 2024
Institute service identifier : EUR-RAD-NMI-1007
CMC ID : EURAMET-RI-MD-00000PL8-1
 
Ionizing radiation
Kerma/rate , Protection level dosemeter or ionization chamber : 3.6 mGy/h to 430 mGy/h
Relative expanded uncertainty 2.9 %
Calibration against secondary standard ionization chamber
X-ray, 10 kV to 50 kV, N40 ISO4037
Reference standard : Secondary standard ionizing chamber PTW32002
Source of traceability : IAEA
Approved on 01 June 2024
Institute service identifier : EUR-RAD-NMI-1005
CMC ID : EURAMET-RI-MD-00000PL6-1
 
Ionizing radiation
Ambient dose equivalent/rate , Protection level ionisation chamber and dosimeter : 1.00E-6 Sv/h to 0.1 Sv/h
Relative expanded uncertainty 4.5 %
Calibration against secondary standard ionisation chamber in reference field in air
Cs-137, Cs-137, 740 GBq 
Reference standard : Secondary standard ionization chamber PTW 32002
Source of traceability : IAEA
Approved on 31 May 2024
Institute service identifier : EUR-RAD-NMI-1003
CMC ID : EURAMET-RI-MD-00000P6F-1
 
Ionizing radiation
Ambient dose equivalent/rate , Protection level dosemeter or ionization chamber : 0.1 mSv/h to 580 mSv/h
Relative expanded uncertainty 4.9 %
Calibration against secondary standard ionization chamber
X-ray, 50 kV to 300 kV, N60-N200 ISO4037
Reference standard : Secondary standard ionizing chamber PTW32002 
Source of traceability : IAEA
Approved on 31 May 2024
Institute service identifier : EUR-RAD-NMI-1004
CMC ID : EURAMET-RI-MD-00000PKS-1
 
Ionizing radiation
Kerma/rate , Dosemeter or ionization chamber for diagnostic radiology : 0.06 Gy/h to 21 Gy/h
Relative expanded uncertainty 3.8 %
Calibration against secondary standard ionization chamber
X-ray, 50 kV to 300 kV, RQR4-RQR10
Reference standard : Secondary standard ionization chamber Exradin A3
Source of traceability : IAEA
Approved on 31 May 2024
Institute service identifier : EUR-RAD-NMI-1008
CMC ID : EURAMET-RI-MD-00000PL9-1
 
Ionizing radiation
Kerma/rate , Protection level ionisation chamber : 1.00E-3 Gy/h to 0.2 Gy/h
Relative expanded uncertainty 1.8 %
Calibration against secondary standard ionisation chamber in reference field in air
Cs-137, ISO 4037-1
Reference standard : Secondary standard ionization chamber PTW 32002
Source of traceability : IAEA
Approved on 15 November 2016
Institute service identifier : COO-RAD-NMI-1002
CMC ID : EURAMET-RI-MD-00000H2D-1
 
Ionizing radiation
Kerma/rate , Protection level dosemeter or ionization chamber : 0.5 mGy/h to 360 mGy/h
Relative expanded uncertainty 2.9 %
Calibration against secondary standard ionization chamber
X-ray, 50 kV to 300 kV, N60-N200 ISO4037
Reference standard : Secondary standard ionizing chamber PTW32002
Source of traceability : IAEA
Approved on 31 May 2024
Institute service identifier : EUR-RAD-NMI-1006
CMC ID : EURAMET-RI-MD-00000PL7-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.