Results for: e+e
Filters
CMC Quick search Filters close;
CMC Area
To filter, either use the tick boxes or click on the underscored item
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Austria, E+E (E+E Elektronik)
Hygrometers ,
Dew-point temperature
:
-55 °C to -25 °C
Dew-point hygrometer
Absolute expanded uncertainty
:
5.0E-2 K
Comparison with humidity generator
Continuous gas flow : Maximum 5 L/min
Atmospheric pressure : (1000 ± 80) hPa
Ambient temperature : (23 ± 3) °C
Approved on 19 March 2012
Institute service identifier : E+E/26
CMC ID :
EURAMET-T-AT-00000BL5-1
Hygrometers ,
Relative humidity
:
0 % to 98 %
Relative humidity hygrometer
Absolute expanded uncertainty
(0.2+t/(-40)*0.1) % + 0.006*h], t (air) temperature in °C t (air) temperature in °C, h relative humidity in %rh
The uncertainty is expressed in %rh
Comparison with humidity generator
Continuous gas flow : Maximum 5 L/min
Atmospheric pressure : (1000 ± 80) hPa
Test chamber temperature : -40 °C to 0 °C
Approved on 10 November 2015
Institute service identifier : E+E/30
CMC ID :
EURAMET-T-AT-00000BLE-1
Hygrometers ,
Relative humidity
:
0 % to 98 %
Relative humidity hygrometer
Absolute expanded uncertainty
0.1 % + 0.004*h h relative humidity in %rh
The uncertainty is expressed in %rh
Comparison with humidity generator
Continuous gas flow : Maximum 5 L/min
Atmospheric pressure : (1000 ± 80) hPa
Test chamber temperature : 0 °C to 65 °C
Approved on 10 November 2015
Institute service identifier : E+E/31
CMC ID :
EURAMET-T-AT-00000BLF-1
Hygrometers ,
Dew-point temperature
:
-25 °C to 20 °C
Dew-point hygrometer
Absolute expanded uncertainty
:
3.5E-2 K
Comparison with humidity generator
Continuous gas flow : Maximum 5 L/min
Atmospheric pressure : (1000 ± 80) hPa
Ambient temperature : (23 ± 3) °C
Approved on 03 November 2009
Institute service identifier : E+E/27
CMC ID :
EURAMET-T-AT-00000BKW-1
Hygrometers ,
Dew-point temperature
:
20 °C to 65 °C
Dew-point hygrometer
Absolute expanded uncertainty
:
3.5E-2 K
Comparison with humidity generator
Continuous gas flow : Maximum 5 L/min
Atmospheric pressure : (1000 ± 80) hPa
Ambient temperature : (23 ± 3) °C
Approved on 03 November 2009
Institute service identifier : E+E/28
CMC ID :
EURAMET-T-AT-00000BKX-1
Hygrometers ,
Dew-point temperature
:
65 °C to 95 °C
Dew-point hygrometer
Absolute expanded uncertainty
:
5.0E-2 K
Comparison with humidity generator
Continuous gas flow : Maximum 5 L/min
Atmospheric pressure : (1000 ± 80) hPa
Ambient temperature : (23 ± 3) °C
Approved on 19 March 2012
Institute service identifier : E+E/29
CMC ID :
EURAMET-T-AT-00000BL6-1
Hygrometers ,
Relative humidity
:
0 % to 98 %
Relative humidity hygrometer
Absolute expanded uncertainty
0.1 % + 0.004*h h relative humidity in %rh
The uncertainty is expressed in %rh
Comparison with humidity generator
Continuous gas flow : Maximum 2 L/min
Atmospheric pressure : (1000 ± 80) hPa
Test chamber temperature : 65 °C to 95 °C
Approved on 10 November 2015
Institute service identifier : E+E/32
CMC ID :
EURAMET-T-AT-00000BLG-1
Brazil, LNMRI/IRD (Laboratorio Nacional de Metrologia das Radiacoes Ionizantes, IRD)
Ionizing radiation
Activity per unit mass
,
Single nuclide, solution
: 2600 Bq/g to 2.60E6 Bq/g
Relative expanded uncertainty 5.2 %
Germanium spectrometer, measured or calculated efficiency, balance
Se-75, 3 mL, LNMRI/IRD glass ampoule
Reference standard : 4 pi [e+X]-gamma coincidence, weight set
Source of traceability : LNMRI/IRD
Approved on 11 April 2019
Institute service identifier : SIM-RAD-LNMRI/IRD-2045
CMC ID :
SIM-RI-BR-00000J44-1
Ionizing radiation
Activity per unit mass
,
Multi nuclide, solution
: 500 Bq/g to 1.00E5 Bq/g
Relative expanded uncertainty 5 %
Germanium spectrometer, measured or calculated efficiency, balance
Ce-139, 3 mL, LNMRI/IRD glass ampoule
Reference standard : 4 pi [e+X]-gamma coincidence, weight set
Source of traceability : LNMRI/IRD
Approved on 11 April 2019
Institute service identifier : SIM-RAD-LNMRI/IRD-2048
CMC ID :
SIM-RI-BR-00000J48-1
Ionizing radiation
Activity per unit mass
,
Multi nuclide, solution
: 500 Bq/g to 1.00E5 Bq/g
Relative expanded uncertainty 5 %
Germanium spectrometer, measured or calculated efficiency, balance
Co-57, 3 mL, LNMRI/IRD glass ampoule
Reference standard : 4 pi [e+X]-gamma coincidence, weight set
Source of traceability : LNMRI/IRD
Approved on 11 April 2019
Institute service identifier : SIM-RAD-LNMRI/IRD-2048
CMC ID :
SIM-RI-BR-00000J49-1
Ionizing radiation
Emission rate
,
Single nuclide, solid
: 100 s-1 to 1.00E6 s-1
Relative expanded uncertainty 5 %
Germanium spectrometer, measured or calculated efficiency
Mn-54, < 1 cm active area, total outside diameter 2.5 cm
Reference standard : 4 pi [e+X]-gamma coincidence, weight set
Source of traceability : LNMRI/IRD
Approved on 11 April 2019
Institute service identifier : SIM-RAD-LNMRI/IRD-2057
CMC ID :
SIM-RI-BR-00000J66-1
Ionizing radiation
Activity per unit mass
,
Single nuclide, solution
: 3.70E4 Bq/g to 1.00E9 Bq/g
Relative expanded uncertainty 0.9 %
Pressurized ionization chamber, balance
Ba-133, 3 mL, LNMRI/IRD glass ampoule
Reference standard : 4 pi [e+X]-gamma coincidence, weight set
Source of traceability : LNMRI/IRD
Approved on 11 April 2019
Institute service identifier : SIM-RAD-LNMRI/IRD-2001
CMC ID :
SIM-RI-BR-00000J5P-1
Ionizing radiation
Activity per unit mass
,
Single nuclide, solid
: 520 Bq/g to 7.40E5 Bq/g
Relative expanded uncertainty 3 %
Planar NaI(Tl) crystals, measured or calculated efficiency, balance
Ba-133, 3 mL, LNMRI/IRD glass ampoule
Reference standard : 4 pi [e+X]-gamma coincidence, weight set
Source of traceability : LNMRI/IRD
Approved on 11 April 2019
Institute service identifier : SIM-RAD-LNMRI/IRD-2059
CMC ID :
SIM-RI-BR-00000J68-1
Ionizing radiation
Activity
,
Single nuclide, solid
: 100 Bq to 5.00E4 Bq
Relative expanded uncertainty 4 %
Germanium spectrometer, measured or calculated efficiency
Ba-133, point source, active area < 5 mm
Reference standard : 4 pi [e+X]-gamma coincidence, weight set
Source of traceability : LNMRI/IRD
Approved on 11 April 2019
Institute service identifier : SIM-RAD-LNMRI/IRD-2018
CMC ID :
SIM-RI-BR-00000J6I-1
Ionizing radiation
Activity per unit mass
,
Single nuclide, solution
: 3.70E5 Bq/g to 1.00E10 Bq/g
Relative expanded uncertainty 0.8 %
Pressurized ionization chamber, balance
Ce-139, 3 mL, LNMRI/IRD glass ampoule
Reference standard : 4 pi [e+X]-gamma coincidence, weight set
Source of traceability : LNMRI/IRD
Approved on 11 April 2019
Institute service identifier : SIM-RAD-LNMRI/IRD-2002
CMC ID :
SIM-RI-BR-00000J5Q-1
Ionizing radiation
Activity per unit mass
,
Single nuclide, solution
: 520 Bq/g to 7.40E5 Bq/g
Relative expanded uncertainty 3.1 %
Planar NaI(Tl) crystals, measured or calculated efficiency, balance
Ce-139, 3 mL, LNMRI/IRD glass ampoule
Reference standard : 4 pi [e+X]-gamma coincidence, weight set
Source of traceability : LNMRI/IRD
Approved on 11 April 2019
Institute service identifier : SIM-RAD-LNMRI/IRD-2060
CMC ID :
SIM-RI-BR-00000J69-1
Ionizing radiation
Activity per unit mass
,
Single nuclide, solution
: 3.70E4 Bq/g to 1.00E9 Bq/g
Relative expanded uncertainty 2.5 %
Pressurized ionization chamber, balance
I-123, 3 mL, LNMRI/IRD glass ampoule
Reference standard : 4 pi [e+X]-gamma coincidence, weight set
Source of traceability : LNMRI/IRD
Approved on 11 April 2019
Institute service identifier : SIM-RAD-LNMRI/IRD-2014
CMC ID :
SIM-RI-BR-00000J6E-1
Ionizing radiation
Activity
,
Single nuclide, solid
: 100 Bq to 1.00E5 Bq
Relative expanded uncertainty 4 %
Germanium spectrometer, measured or calculated efficiency
Mn-54, point source, active area < 5 mm
Reference standard : 4 pi [e+X]-gamma coincidence, weight set
Source of traceability : LNMRI/IRD
Approved on 11 April 2019
Institute service identifier : SIM-RAD-LNMRI/IRD-2024
CMC ID :
SIM-RI-BR-00000J6O-1
Ionizing radiation
Activity per unit mass
,
Single nuclide, solution
: 50 Bq/g to 1.00E6 Bq/g
Relative expanded uncertainty 3 %
Germanium spectrometer, measured or calculated efficiency, balance
Ba-133, 3 mL, LNMRI/IRD glass ampoule
Reference standard : 4 pi [e+X]-gamma coincidence, weight set
Source of traceability : LNMRI/IRD
Approved on 11 April 2019
Institute service identifier : SIM-RAD-LNMRI/IRD-2028
CMC ID :
SIM-RI-BR-00000J75-1
Ionizing radiation
Activity per unit mass
,
Single nuclide, solution
: 6.00E6 Bq/g to 3.00E11 Bq/g
Relative expanded uncertainty 3 %
Pressurized ionization chamber, balance
I-125, 3 mL, LNMRI/IRD glass ampoule
Reference standard : 4 pi [e+X]-gamma anticoincidence, weight set
Source of traceability : LNMRI/IRD
Approved on 11 April 2019
Institute service identifier : SIM-RAD-LNMRI/IRD-2087
CMC ID :
SIM-RI-BR-00000J7G-1