Results for: paraguay
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
14 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Paraguay, INTN (Instituto Nacional de Tecnologia y Normalizacion)
Mass , Conventional mass : 1 mg to 100 mg
Mass standard
Absolute expanded uncertainty : 3.0E-3 mg to 5.0E-3 mg
Direct comparison
Temperature : 23 °C
Humidity : 40 % to 60 %
Pressure : 1000 hPa
Approved on 18 June 2019
Institute service identifier : INTN/ONM-Masa
CMC ID : SIM-M-PY-00000GHZ-1
 
Pressure , Gauge pressure: oil medium : 2.00E5 Pa to 1.00E8 Pa
Pressure gauge
Absolute expanded uncertainty
1.98E-04p + 2.14E+02

The uncertainty is expressed in Pa

Direct comparison
Temperature : (20 ± 2) °C
p pressure in Pa
Approved on 27 January 2017
Institute service identifier : INTN/ONM - Presión
CMC ID : SIM-M-PY-00000GHY-1
 
Fluid flow , Volume of liquid : 1 mL to 5 mL
Volumetric test measure (one mark pipette)
Absolute expanded uncertainty : 2.0E-3 mL to 6.0E-3 mL
0.001V + 0.001

V in mL
Gravimetric determination
ISO 4787
Fluid : Pure water
Temperature : (18 to 25) °C
Approved on 23 September 2023
Institute service identifier : INTN/ONM-Volumen
CMC ID : SIM-M-PY-00000NDD-1
 
Mass , Conventional mass : 10 g to 100 g
Mass standard
Absolute expanded uncertainty : 2.0E-2 mg to 5.0E-2 mg
Direct comparison
Temperature : 23 °C
Humidity : 40 % to 60 %
Pressure : 1000 hPa
Approved on 18 June 2019
Institute service identifier : INTN/ONM-Masa
CMC ID : SIM-M-PY-00000GI2-1
 
Mass , Conventional mass : 20 kg
Mass standard
Absolute expanded uncertainty : 3.0E1 mg
Direct comparison
Temperature : 23 °C
Humidity : 40 % to 60 %
Pressure : 1000 hPa
Approved on 18 June 2019
Institute service identifier : INTN/ONM-Masa
CMC ID : SIM-M-PY-00000GI5-1
 
Fluid flow , Volume of liquid : 10 mL to 100 mL
Volumetric test measure (pycnometer)
Absolute expanded uncertainty : 3.6E-3 mL to 8.1E-3 mL
0.00005V + 0.0031

V in mL
Gravimetric determination
Fluid : Pure water
Temperature : (18 to 25) °C
Approved on 30 September 2023
Institute service identifier : INTN/ONM-Volumen
CMC ID : SIM-M-PY-00000NDG-1
 
Mass , Conventional mass : 1 g to 10 g
Mass standard
Absolute expanded uncertainty : 1.0E-2 mg to 2.0E-2 mg
Direct comparison
Temperature : 23 °C
Humidity : 40 % to 60 %
Pressure : 1000 hPa
Approved on 18 June 2019
Institute service identifier : INTN/ONM-Masa
CMC ID : SIM-M-PY-00000GI1-1
 
Mass , Conventional mass : 1 kg to 10 kg
Mass standard
Absolute expanded uncertainty : 0.5 mg to 1.6E1 mg
Direct comparison
Temperature : 23 °C
Humidity : 40 % to 60 %
Pressure : 1000 hPa
Approved on 18 June 2019
Institute service identifier : INTN/ONM-Masa
CMC ID : SIM-M-PY-00000GI4-1
 
Mass , Conventional mass : 0.1 kg to 1 kg
Mass standard
Absolute expanded uncertainty
0.050 to 0.50

The uncertainty is expressed in mg

Direct comparison
Temperature : 23 °C
Humidity : 40 % to 60 %
Pressure : 1000 hPa
Approved on 18 June 2019
Institute service identifier : INTN/ONM-Masa
CMC ID : SIM-M-PY-00000GI3-1
 
Fluid flow , Volume of liquid : 1 mL to 1000 mL
Volumetric test measure (flask)
Absolute expanded uncertainty : 3.7E-3 mL to 0.1 mL
0.0001V + 0.0036

 V  in mL
Gravimetric determination
ISO 4787
Fluid : Pure water
Temperature : (18  to 25) °C
Approved on 23 September 2023
Institute service identifier : INTN/ONM-Volumen
CMC ID : SIM-M-PY-00000NDC-1
 
Fluid flow , Volume of liquid : 10 mL to 100 mL
Volumetric test measure (one mark pipette)
Absolute expanded uncertainty : 7.0E-3 mL to 1.6E-2 mL
0.0001V + 0.006

V in mL
Gravimetric determination
ISO 4787
Fluid : Pure water
Temperature : (18 to 25) °C
Approved on 30 September 2023
Institute service identifier : INTN/ONM-Volumen
CMC ID : SIM-M-PY-00000NDE-1
 
Mass , Conventional mass : 0.1 g to 1 g
Mass standard
Absolute expanded uncertainty : 5.0E-3 mg to 1.0E-2 mg
Direct comparison
Temperature : 23 °C
Humidity : 40 % to 60 %
Pressure : 1000 hPa
Approved on 18 June 2019
Institute service identifier : INTN/ONM-Masa
CMC ID : SIM-M-PY-00000GI0-1
 
Fluid flow , Volume of liquid : 10 mL to 100 mL
Volumetric test measure (graduated pipette and burette)
Absolute expanded uncertainty : 8.1E-3 mL to 5.3E-2 mL
0.0005 V + 0.0031

V in mL
Gravimetric determination
ISO 4787
Fluid : Pure water
Temperature : (18 to 25) °C
Approved on 30 September 2023
Institute service identifier : INTN/ONM-Volumen
CMC ID : SIM-M-PY-00000NDF-1
 
Fluid flow , Volume of liquid : 20 µL to 1.00E4 µL
Volumetric test measure (piston pipettes)
Absolute expanded uncertainty : 0.15 µL to 2.5E1 µL
0.0025V + 0.10

V in μL
Gravimetric determination
ISO 8655-6
Fluid : Pure water
Temperature : (18 to 23) °C
Approved on 30 September 2023
Institute service identifier : INTN/ONM-Volumen
CMC ID : SIM-M-PY-00000NDH-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.