Results for: IAEA
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
23 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
IAEA - International Organization, IAEA (International Atomic Energy Agency)
Ionizing radiation
Kerma/rate , Diagnostic ionisation chamber : 1.70E-5 Gy/s to 1.00E-3 Gy/s
Relative expanded uncertainty 1.3 %
Calibration against a secondary standard free in air
X-ray, 10 kV to 50 kV, Mammography qualities (anode material + x mm of filter material)
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Mammography qualities (i) Mo + 0.03 Mo, with and without additional 2 mm Al for 25 kV to 35 kV, IEC61627 RQR-M and RQA-M for 25 kV to 35 kV; (ii) Mo + 0.028 Rh, 25 kV to 35 kV; W + 0.048 Rh, 25 kV to 35 kV; W + 0.049 Ag, 25 kV to 35 kV
Approved on 21 October 2001
Institute service identifier : SIM-RAD-IAEA-1018
CMC ID : SIM-RI-IA-00000OZV-1
 
Ionizing radiation
Ambient dose equivalent/rate , Protection ionization chamber : 0.036 mSv/h to 9 mSv/h
Relative expanded uncertainty 3.5 % to 1.2 %
Calibration against a secondary standard free in air
Cs-137, ISO 4037
Reference standard : Secondary standard ionization chamber
Source of traceability : BIPM
Traceable to the H*(10) standard at the BIPM without conversion from air kerma Uncertainty varies linearly within the range
Approved on 24 February 2016
Institute service identifier : SIM-RAD-IAEA-1012
CMC ID : SIM-RI-IA-00000P07-1
 
Ionizing radiation
Ambient dose equivalent/rate , Protection ionization chamber : 0.11 mSv/h to 3 mSv/h
Relative expanded uncertainty 0.8 %
Calibration against a secondary standard free in air
Co-60, ISO 4037
Reference standard : Secondary standard ionization chamber
Source of traceability : BIPM
Traceable to the H*(10) standard at the BIPM without conversion from air kerma
Approved on 24 February 2016
Institute service identifier : SIM-RAD-IAEA-1013
CMC ID : SIM-RI-IA-00000P06-1
 
Ionizing radiation
Personal dose equivalent/rate , Protection ionization chamber / personal dosimeter : 0.05 mSv to 30 mSv
Relative expanded uncertainty 5 %
Calibration against a secondary standard on the surface of the slab phantom
Cs-137, ISO 4037
Reference standard : Secondary standard ionization chamber
Source of traceability : BIPM
Approved on 24 February 2016
Institute service identifier : SIM-RAD-IAEA-1016
CMC ID : SIM-RI-IA-00000OZO-1
 
Ionizing radiation
Personal dose equivalent/rate , Protection ionization chamber / personal dosimeter : 0.05 mSv to 30 mSv
Relative expanded uncertainty 5 %
Calibration against a secondary standard on the surface of the slab phantom
Co-60, ISO 4037
Reference standard : Secondary standard ionization chamber
Source of traceability : BIPM
Approved on 24 February 2016
Institute service identifier : SIM-RAD-IAEA-1017
CMC ID : SIM-RI-IA-00000OZN-1
 
Ionizing radiation
Kerma/rate , Therapy ionization chamber : 4.00E-4 Gy/s to 4.00E-3 Gy/s
Relative expanded uncertainty 0.8 %
Calibration against a secondary standard free in air
X-ray, 10 kV to 50 kV, BIPM-CCRI, 10 kV to 50 kV
Reference standard : Secondary standard ionization chamber
Source of traceability : BIPM
Approved on 24 February 2016
Institute service identifier : SIM-RAD-IAEA-1003
CMC ID : SIM-RI-IA-00000OZQ-1
 
Ionizing radiation
Personal dose equivalent/rate , Protection ionization chamber / personal dosimeter : 0.2 mSv to 30 mSv
Relative expanded uncertainty 5 %
Calibration against a secondary standard on the surface of the slab phantom
X-ray, 50 kV to 300 kV, ISO 4037, Narrow Series, 60 kV to 300 kV
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 February 2016
Institute service identifier : SIM-RAD-IAEA-1015
CMC ID : SIM-RI-IA-00000OZM-1
 
Ionizing radiation
Kerma/rate , Protection ionization chamber : 0.036 mGy/h to 9 mGy/h
Relative expanded uncertainty 3.2 % to 0.8 %
Calibration against a secondary standard free in air
Cs-137, ISO 4037
Reference standard : Secondary standard ionization chamber
Source of traceability : BIPM
Uncertainty varies linearly within the range
Approved on 24 February 2016
Institute service identifier : SIM-RAD-IAEA-1008
CMC ID : SIM-RI-IA-00000P03-1
 
Ionizing radiation
Kerma/rate , Protection ionization chamber : 0.6 mGy/h to 12 mGy/h
Relative expanded uncertainty 1.2 %
Calibration against a secondary standard free in air
X-ray, 10 kV to 50 kV, ISO 4037, Narrow Series, 40 kV
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 February 2016
Institute service identifier : SIM-RAD-IAEA-1006
CMC ID : SIM-RI-IA-00000OZT-1
 
Ionizing radiation
Kerma/rate , Protection ionization chamber : 0.11 mGy/h to 3 mGy/h
Relative expanded uncertainty 0.8 %
Calibration against a secondary standard free in air
Co-60, ISO 4037
Reference standard : Secondary standard ionization chamber
Source of traceability : BIPM
Approved on 24 February 2016
Institute service identifier : SIM-RAD-IAEA-1009
CMC ID : SIM-RI-IA-00000P02-1
 
Ionizing radiation
Personal dose equivalent/rate , Protection ionization chamber / personal dosimeter : 0.2 mSv to 30 mSv
Relative expanded uncertainty 5 %
Calibration against a secondary standard on the surface of the slab phantom
X-ray, 10 kV to 50 kV, ISO 4037, Narrow Series, 40 kV
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 February 2016
Institute service identifier : SIM-RAD-IAEA-1014
CMC ID : SIM-RI-IA-00000OZL-1
 
Ionizing radiation
Ambient dose equivalent/rate , Protection ionization chamber : 0.6 mSv/h to 12 mSv/h
Relative expanded uncertainty 3.3 %
Calibration against a secondary standard free in air
X-ray, 50 kV to 300 kV, ISO 4037, Narrow Series, 60 kV to 300 kV
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 February 2016
Institute service identifier : SIM-RAD-IAEA-1011
CMC ID : SIM-RI-IA-00000P05-1
 
Ionizing radiation
Kerma/rate , Diagnostic ionisation chamber : 1.70E-5 Gy/s to 1.40E-4 Gy/s
Relative expanded uncertainty 1.1 %
Calibration against a secondary standard free in air
X-ray, 50 kV to 300 kV, IEC 61267, RQA series, 60 kV to 150 kV
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 February 2016
Institute service identifier : SIM-RAD-IAEA-1021
CMC ID : SIM-RI-IA-00000P00-1
 
Ionizing radiation
Kerma/rate , Protection ionization chamber : 0.6 mGy/h to 12 mGy/h
Relative expanded uncertainty 1.2 %
Calibration against a secondary standard free in air
X-ray, 50 kV to 300 kV, ISO 4037, Narrow Series, 60 kV to 300 kV
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 February 2016
Institute service identifier : SIM-RAD-IAEA-1007
CMC ID : SIM-RI-IA-00000OZX-1
 
Ionizing radiation
Kerma/rate , Diagnostic ionisation chamber : 1.70E-4 Gy/s to 1.20E-3 Gy/s
Relative expanded uncertainty 1.1 %
Calibration against a secondary standard free in air
X-ray, 50 kV to 300 kV, IEC 61267, RQR series, 60 kV to 150 kV
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 February 2016
Institute service identifier : SIM-RAD-IAEA-1023
CMC ID : SIM-RI-IA-00000OZY-1
 
Ionizing radiation
Kerma/rate , Diagnostic ionisation chamber : 1.70E-4 Gy/s to 1.20E-3 Gy/s
Relative expanded uncertainty 1.1 %
Calibration against a secondary standard free in air
X-ray, 10 kV to 50 kV, IEC 61267, RQR series, 40 kV to 50 kV
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 February 2016
Institute service identifier : SIM-RAD-IAEA-1022
CMC ID : SIM-RI-IA-00000OZU-1
 
Ionizing radiation
Kerma/rate , Diagnostic ionisation chamber : 1.70E-5 Gy/s to 1.40E-4 Gy/s
Relative expanded uncertainty 1.1 %
Calibration against a secondary standard free in air
X-ray, 10 kV to 50 kV, IEC 61267, RQA series, 40 kV to 50 kV
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 February 2016
Institute service identifier : SIM-RAD-IAEA-1020
CMC ID : SIM-RI-IA-00000OZR-1
 
Ionizing radiation
Kerma/rate , Diagnostic ionisation chamber : 1.70E-5 Gy/s to 1.00E-3 Gy/s
Relative expanded uncertainty 1 %
Calibration against a secondary standard free in air
X-ray, 10 kV to 50 kV, Mammography qualities
Reference standard : Secondary standard ionization chamber
Source of traceability : BIPM
Mammography qualities (anode material + x mm of filter material): (i) Mo + 0.03 Mo (IEC61267 RQR-M), 25 kV to 35 kV, and W + 0.066 Mo, 25 kV to 35 kV
Approved on 24 February 2016
Institute service identifier : SIM-RAD-IAEA-1019
CMC ID : SIM-RI-IA-00000OZS-1
 
Ionizing radiation
Kerma/rate , Diagnostic ionisation chamber : 1.70E-4 Gy/s to 1.70E-3 Gy/s
Relative expanded uncertainty 1.1 %
Calibration against a secondary standard free in air
X-ray, 50 kV to 300 kV, IEC 61267, RQT beams, 100 kV to 150 kV
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 February 2016
Institute service identifier : SIM-RAD-IAEA-1024
CMC ID : SIM-RI-IA-00000OZW-1
 
Ionizing radiation
Kerma/rate , Therapy ionization chamber : 2.00E-4 Gy/s to 2.00E-3 Gy/s
Relative expanded uncertainty 0.8 %
Calibration against a secondary standard free in air
X-ray, 50 kV to 300 kV, BIPM-CCRI, 100 kV to 250 kV
Reference standard : Secondary standard ionization chamber
Source of traceability : BIPM
Approved on 24 February 2016
Institute service identifier : SIM-RAD-IAEA-1004
CMC ID : SIM-RI-IA-00000OZZ-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.