In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Serbia, DMDM (Directorate of Measures and Precious Metals)
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -40 °C to 20 °C
Liquid-in-glass thermometer resolution 0.1 °C
Absolute expanded uncertainty : 3.3E-2 °C
Calibration by comparison
Ethanol bath
Approved on 03 November 2009
Institute service identifier : DMDM/T06-4
Time interval , Time interval : 1.00E-9 s to 1 s
Delay source
Absolute expanded uncertainty : 0.2 ns
Time interval counter
Slewing rate : 0.5 V/ns
Approved on 10 March 2008
Institute service identifier : DMDM/TF-3.2.4
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -40 °C to 20 °C
Liquid-in-glass thermometer resolution 1 °C
Absolute expanded uncertainty : 0.35 °C
Calibration by comparison
Ethanol bath
Approved on 03 November 2009
Institute service identifier : DMDM/T06-7
Impedance (up to the MHz range) , Capacitance for dielectric capacitors : 0.01 nF to 1.00E4 nF
Fixed capacitor, switched capacitor, capacitance box
Relative expanded uncertainty : 0.59 mF/F to 8.1 mF/F
{"row_1":{"col_1":"","col_2":"20 Hz","col_3":"120 Hz","col_4":"1 kHz","col_5":"10 kHz","col_6":"100 kHz","col_7":"1 MHz","col_8":"2 MHz"},"row_2":{"col_1":"0.01 nF","col_2":"-","col_3":"-","col_4":"-","col_5":"-","col_6":"0.81","col_7":"0.72 to 0.81","col_8":"0.84"},"row_3":{"col_1":"0.1 nF","col_2":"-","col_3":"-","col_4":"-","col_5":"-","col_6":"0.62","col_7":"0.61 to 0.63","col_8":"0.71"},"row_4":{"col_1":"1 nF","col_2":"-","col_3":"-","col_4":"0.71 to 1.31","col_5":"-","col_6":"-","col_7":"0.59 to 0.69","col_8":"0.60 to 0.78"},"row_5":{"col_1":"100 nF","col_2":"-","col_3":"0.6","col_4":"-","col_5":"-","col_6":"0.69","col_7":"-","col_8":"-"},"row_6":{"col_1":"10000 nF","col_2":"3.06","col_3":"3.06","col_4":"3.1","col_5":"3.56","col_6":"8.07","col_7":"-","col_8":"-"}}
The expanded uncertainties given in this table are expressed in mF/F
LCR meter
Frequency : 20 Hz to 2 MHz
Approved on 06 August 2013
Institute service identifier : DMDM/109
AC current , AC current up to 100 A: sources : 1.00E-3 A to 2 A
Multifunction calibrator, transconductance amplifier
Absolute expanded uncertainty : 4.2E-4 mA to 2.3 mA
{"row_1":{"col_1":"","col_2":"10 Hz ","col_3":"20 Hz","col_4":"21 Hz to 45 Hz","col_5":"46 Hz to 400 Hz","col_6":"401 Hz to 1 kHz ","col_7":"1.1 kHz to 5 kHz","col_8":"5.1 kHz to 10 kHz"},"row_2":{"col_1":"1 mA","col_2":"0.00042","col_3":"0.00042","col_4":"0.00042","col_5":"0.00042","col_6":"0.00042","col_7":"0.00042","col_8":"0.00043"},"row_3":{"col_1":"10 mA","col_2":"0.012","col_3":"0.0032","col_4":"0.0020","col_5":"0.0020","col_6":"0.0020","col_7":"0.0020","col_8":"0.0020"},"row_4":{"col_1":"100 mA","col_2":"0.12","col_3":"0.029","col_4":"0.018","col_5":"0.018","col_6":"0.018","col_7":"0.018","col_8":"0.019"},"row_5":{"col_1":"200 mA","col_2":"0.23","col_3":"0.059","col_4":"0.037","col_5":"0.037","col_6":"0.037","col_7":"0.037","col_8":"0.037"},"row_6":{"col_1":"500 mA","col_2":"0.58","col_3":"0.15","col_4":"0.092","col_5":"0.092","col_6":"0.092","col_7":"0.092","col_8":"0.093"},"row_7":{"col_1":"1 A","col_2":"1.05","col_3":"0.26","col_4":"0.17","col_5":"0.17","col_6":"0.17","col_7":"0.17","col_8":"0.17"},"row_8":{"col_1":"2 A","col_2":"2.34","col_3":"0.59","col_4":"0.37","col_5":"0.37","col_6":"0.37","col_7":"0.37","col_8":"0.37"}}
The expanded uncertainty given in this table are expressed in mA
Voltage drop across current shunt
Frequency : 10 Hz to 10 kHz
Approved on 06 January 2015
Institute service identifier : DMDM/100
DC current (up to 100 A) , DC current sources: low values : 0.1 mA
Current generator, multifunction calibrator
Absolute expanded uncertainty : 1.3 nA
Voltage drop across standard resistor
Power dissipation of standard resistor : 0.1 mW
Approved on 06 August 2013
Institute service identifier : DMDM/78
Items for defining ITS-90 , Temperature : -38.8344 °C
Long SPRT in Mercury triple point
Absolute expanded uncertainty : 1 mK
Direct comparison
Ethanol bath
Approved on 17 January 2013
Institute service identifier : DMDM/T01-2
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS1P
Absolute expanded uncertainty : 8.0E-2 dB
IEC 61094-2:1992
Frequency : 63 Hz to 3.15 kHz
Approved on 27 February 2014
Institute service identifier : DMDM/1.1
Impedance (up to the MHz range) , Capacitance: meters : 1 pF to 1000 pF
Capacitance bridge, LCR meter
Relative expanded uncertainty : 5.0E-3 mF/F to 0.26 mF/F
{"row_1":{"col_1":"","col_2":" 1 kHz","col_3":"100 Hz to 1 MHz"},"row_2":{"col_1":"1 pF","col_2":"0.01","col_3":"0.03 to 0.26"},"row_3":{"col_1":"10 pF","col_2":"0.007","col_3":"0.012 to 0.13"},"row_4":{"col_1":"100 pF","col_2":"0.007","col_3":"0.012 to 0.09"},"row_5":{"col_1":"1000 pF","col_2":"0.005","col_3":"0.01 to 0.014"}}
The expanded uncertainties given in this table are expressed in mF/F
Direct measurement
Frequency : 100 Hz to 1 MHz
Approved on 06 August 2013
Institute service identifier : DMDM/110
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS1P
Absolute expanded uncertainty : 9.0E-2 dB
IEC 61094-2:1992
Frequency : 4 kHz
Approved on 27 February 2014
Institute service identifier : DMDM/1.1
DC voltage (up to 1100 V) , DC voltage sources: single values : 1 V to 10 V
Standard cell, solid state voltage standard
Absolute expanded uncertainty : 0.45 µV to 1.0E1 µV
{"row_1":{"col_1":"","col_2":"Expanded uncertainty / µV ","col_3":"Reference Stanard used in calibration"},"row_2":{"col_1":"1.018 V","col_2":"0.12","col_3":"Josephson Voltage Standard"},"row_3":{"col_1":"1 V","col_2":"0.12","col_3":"Josephson Voltage Standard"},"row_4":{"col_1":"10 V","col_2":"0.04","col_3":"Josephson Voltage Standard"},"row_5":{"col_1":"1.018 V","col_2":"0.45","col_3":"Group of standard cells and solid state voltage standards"},"row_6":{"col_1":"1 V","col_2":"1","col_3":"Group of standard cells and solid state voltage standards"},"row_7":{"col_1":"10 V","col_2":"1","col_3":"Group of standard cells and solid state voltage standards"}}
Difference measurement
Fixed voltage : 1.018 V, 1 V, 10 V
Approved on 06 August 2013
Institute service identifier : DMDM/1
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -40 °C to 20 °C
Platinum Resistance Thermometer
Absolute expanded uncertainty : 9.0E-3 °C
Calibration by comparison
Ethanol bath
Approved on 03 November 2009
Institute service identifier : DMDM/T02-1
DC resistance , DC resistance standards and sources: high values : 1.00E7 Ω to 1.00E9 Ω
Fixed resistor, resistance box
Relative expanded uncertainty : 6.0E1 µΩ/Ω to 5.0E3 µΩ/Ω
{"row_1":{"col_1":"","col_2":"Expanded uncertainty / (µΩ/Ω)"},"row_2":{"col_1":"100 µΩ","col_2":"20"},"row_3":{"col_1":"1 mΩ","col_2":"10"},"row_4":{"col_1":"10 mΩ","col_2":"2.5"},"row_5":{"col_1":"100 mΩ","col_2":"1.5"},"row_6":{"col_1":"1 Ω","col_2":"0.2"},"row_7":{"col_1":"10 Ω","col_2":"0.33"},"row_8":{"col_1":"100 Ω","col_2":"0.39"},"row_9":{"col_1":"1000 Ω","col_2":"0.24"},"row_10":{"col_1":"10000 Ω","col_2":"0.29"},"row_11":{"col_1":"100 kΩ","col_2":"2.6"},"row_12":{"col_1":"1 MΩ","col_2":"6.5"},"row_13":{"col_1":"10 MΩ","col_2":"60"},"row_14":{"col_1":"100 MΩ","col_2":" 500"},"row_15":{"col_1":"1 GΩ","col_2":"5000"}}
Comparison by means of a binary voltage divider bridge
Voltage : 90.9 V
Fixed resistor in oil or air bath, temperature: 23 °C
Approved on 06 January 2015
Institute service identifier : DMDM/121
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS2P
Absolute expanded uncertainty : 0.15 dB
IEC 61094-2:1992
Frequency : 16 kHz
Approved on 27 February 2014
Institute service identifier : DMDM/1.2
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS2P
Absolute expanded uncertainty : 0.46 dB
IEC 61094-2:1992
Frequency : 25 kHz
Approved on 27 February 2014
Institute service identifier : DMDM/1.2
Frequency , Frequency : 10 MHz
Local frequency standard
Relative expanded uncertainty : 1.0E-13 Hz/Hz
Phase time measurement
Averaging time : 1 day
Approved on 10 March 2008
Institute service identifier : DMDM/TF-2.1.1b
Time scale difference , Time scale difference : -1 s to 1 s
Local clock vs UTC
Absolute expanded uncertainty : 2.0E1 ns
Comparison against post-processed UTC
Averaging time : 5 days
Pulse amplitude : 1 V to 5 V
Slewing rate : > 0.5 V/ns
Fractional part of modulo 1 second difference, integer part can be provided also
Approved on 10 March 2008
Institute service identifier : DMDM/TF-1.1.2b
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 300 °C to 600 °C
Base-metal thermocouple
Absolute expanded uncertainty : 0.51 °C to 0.87 °C
Calibration by comparison
Comparison furnace
Approved on 19 March 2012
Institute service identifier : DMDM/T04-5
Measurement microphones , Pressure sensitivity level
Measurement microphone type LS1P
Absolute expanded uncertainty : 0.14 dB
IEC 61094-2:1992
Frequency : 8 kHz
Approved on 27 February 2014
Institute service identifier : DMDM/1.1
Photometry , Luminous intensity : 1 cd to 1.00E4 cd
Tungsten lamp
Relative expanded uncertainty : 2 %
Photometric bench, reference lamps / photometer
Colour temperature : 2353 K, 2800 K and 2856 K
Approved on 30 September 2010

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.