Results for: Sweden "SSM"
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
23 results
Reset all
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Sweden, SSM (Swedish Radiation Safety Authority)
Ionizing radiation
Ambient dose equivalent/rate , Radioprotection dosemeter : 1.00E-5 Sv/h to 8.00E-4 Sv/h
Relative expanded uncertainty 5 %
Calibration free in air
Co-60, ISO 4037-1
Reference standard : Secondary standard ionization chamber
Source of traceability : BIPM
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1010
CMC ID : EURAMET-RI-SE-00000GYV-1
 
Ionizing radiation
Directional dose equivalent/rate , Radioprotection dosemeter : 5.00E-4 Sv/h to 3.00E-3 Sv/h
Relative expanded uncertainty 5 %
Calibration free in air
X-ray, 50 kV to 420 kV, 55 kV to 240 kV ISO 4037-1, low air-kerma rate series
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1016
CMC ID : EURAMET-RI-SE-00000GZ0-1
 
Ionizing radiation
Kerma/rate , Radiotherapy dosemeter, radiodiagnostic dosemeter : 1.00E-4 Gy/s to 3.00E-3 Gy/s
Relative expanded uncertainty 1.4 %
Calibration free in air
X-ray, 10 kV to 50 kV, 10 kV to 50 kV, BIPM report 91/5 1991
Reference standard : Two secondary standard ionization chambers
Source of traceability : BIPM
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1002
CMC ID : EURAMET-RI-SE-00000GYN-1
 
Ionizing radiation
Directional dose equivalent/rate , Radioprotection dosemeter : 5.00E-4 Sv/h to 3.00E-3 Sv/h
Relative expanded uncertainty 5 %
Calibration free in air
X-ray, 10 kV to 50 kV, 35 kV ISO 4037-1, low air-kerma rate series
Reference standard : Secondary standard ionization chamber
Source of traceability : BIPM
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1015
CMC ID : EURAMET-RI-SE-00000GYZ-1
 
Ionizing radiation
Personal dose equivalent/rate, penetrating , Dosimeter : 1.00E-4 Sv to 0.1 Sv
Relative expanded uncertainty 5 %
Irradiation or calibration on a water slab, rod or pillar phantom
Co-60, ISO 4037-1
Reference standard : Secondary standard ionization chamber
Source of traceability : BIPM
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1018
CMC ID : EURAMET-RI-SE-00000GZ1-1
 
Ionizing radiation
Kerma/rate , Radiodiagnostic dosemeter : 300 mGy/h to 700 mGy/h
Relative expanded uncertainty 2.4 %
Calibration free in air
X-ray, 10 kV to 50 kV, 40 kV, IEC 61267, RQR-series
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1004
CMC ID : EURAMET-RI-SE-00000GYP-1
 
Ionizing radiation
Kerma/rate , Radiodiagnostic dosemeter : 30 mGy/h to 70 mGy/h
Relative expanded uncertainty 2.4 %
Calibration free in air
X-ray, 10 kV to 50 kV, 40 kV, IEC 61267, RQA-series
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1006
CMC ID : EURAMET-RI-SE-00000GYR-1
 
Ionizing radiation
Personal dose equivalent/rate, superficial , Dosimeter : 1.00E-4 Sv to 0.1 Sv
Relative expanded uncertainty 5 %
Irradiation or calibration on a water slab, rod or pillar phantom
Cs-137, ISO 4037-1
Reference standard : Secondary standard ionization chamber
Source of traceability : BIPM
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1024
CMC ID : EURAMET-RI-SE-00000GZ6-1
 
Ionizing radiation
Ambient dose equivalent/rate , Radioprotection dosemeter : 5.00E-4 Sv/h to 3.00E-3 Sv/h
Relative expanded uncertainty 5 %
Calibration free in air
X-ray, 10 kV to 50 kV, 35 kV ISO 4037-1, low air-kerma rate series
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1012
CMC ID : EURAMET-RI-SE-00000GYX-1
 
Ionizing radiation
Personal dose equivalent/rate, superficial , Dosimeter : 1.00E-4 Sv to 0.1 Sv
Relative expanded uncertainty 5 %
Irradiation or calibration on a water slab, rod or pillar phantom
Co-60, ISO 4037-1
Reference standard : Secondary standard ionization chamber
Source of traceability : BIPM
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1023
CMC ID : EURAMET-RI-SE-00000GZ5-1
 
Ionizing radiation
Ambient dose equivalent/rate , Radioprotection dosemeter : 2.00E-6 Sv/h to 0.1 Sv/h
Relative expanded uncertainty 5 %
Calibration free in air
Cs-137, ISO 4037-1
Reference standard : Secondary standard ionization chamber
Source of traceability : BIPM
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1011
CMC ID : EURAMET-RI-SE-00000GYW-1
 
Ionizing radiation
Kerma/rate , Radiodiagnostic dosemeter : 30 mGy/h to 70 mGy/h
Relative expanded uncertainty 2.4 %
Calibration free in air
X-ray, 50 kV to 420 kV, 50 kV to 150 kV, IEC 61267, RQA-series
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1007
CMC ID : EURAMET-RI-SE-00000GYS-1
 
Ionizing radiation
Ambient dose equivalent/rate , Radioprotection dosemeter : 5.00E-4 Sv/h to 3.00E-3 Sv/h
Relative expanded uncertainty 5 %
Calibration free in air
X-ray, 50 kV to 420 kV, 55 kV to 240 kV ISO 4037-1, low air-kerma rate series
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1013
CMC ID : EURAMET-RI-SE-00000GYY-1
 
Ionizing radiation
Kerma/rate , Radiotherapy dosemeter : 1.00E-4 Gy/s to 3.00E-3 Gy/s
Relative expanded uncertainty 0.7 %
Calibration free in air
X-ray, 50 kV to 420 kV, 100 kV to 250 kV, BIPM Report 91/5 1991
Reference standard : Two secondary standard ionization chambers
Source of traceability : BIPM
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1003
CMC ID : EURAMET-RI-SE-00000GYO-1
 
Ionizing radiation
Personal dose equivalent/rate, penetrating , Dosimeter : 1.00E-4 Sv to 0.1 Sv
Relative expanded uncertainty 5 %
Irradiation or calibration on a water slab, rod or pillar phantom
Cs-137, ISO 4037-1
Reference standard : Secondary standard ionization chamber
Source of traceability : BIPM
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1019
CMC ID : EURAMET-RI-SE-00000GZ2-1
 
Ionizing radiation
Kerma/rate , Radiotherapy dosemeter : 2.00E-3 Gy/s to 0.012 Gy/s
Relative expanded uncertainty 0.8 %
Calibration free in air
Co-60, IAEA 277
Reference standard : Two secondary standard ionization chambers
Source of traceability : BIPM
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1001
CMC ID : EURAMET-RI-SE-00000GYM-1
 
Ionizing radiation
Kerma/rate , Radiodiagnostic dosemeter : 300 mGy/h to 700 mGy/h
Relative expanded uncertainty 2.4 %
Calibration free in air
X-ray, 50 kV to 420 kV, 50 kV to 150 kV, IEC 61267, RQR-series
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1005
CMC ID : EURAMET-RI-SE-00000GYQ-1
 
Ionizing radiation
Personal dose equivalent/rate, superficial , Dosimeter : 1.00E-4 Sv to 0.1 Sv
Relative expanded uncertainty 5 %
Irradiation or calibration on a water slab, rod or pillar phantom
X-ray, 10 kV to 50 kV, 40 kV ISO 4037-1, Narrow-spectrum series
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1025
CMC ID : EURAMET-RI-SE-00000GZ7-1
 
Ionizing radiation
Personal dose equivalent/rate, penetrating , Dosimeter : 1.00E-4 Sv to 0.1 Sv
Relative expanded uncertainty 5 %
Irradiation or calibration on a water slab, rod or pillar phantom
X-ray, 10 kV to 50 kV, 40 kV ISO 4037-1, Narrow-spectrum series
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1020
CMC ID : EURAMET-RI-SE-00000GZ3-1
 
Ionizing radiation
Personal dose equivalent/rate, superficial , Dosimeter : 1.00E-4 Sv to 0.1 Sv
Relative expanded uncertainty 5 %
Irradiation or calibration on a water slab, rod or pillar phantom
X-ray, 50 kV to 420 kV, 60 kV to 300 kV ISO 4037-1, Narrow-spectrum series
Reference standard : Secondary standard ionization chamber
Source of traceability : PTB
Approved on 24 January 2012
Institute service identifier : EUR-RAD-SSM-1026
CMC ID : EURAMET-RI-SE-00000GZ8-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.