Results for: Spain "ROA"
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
25 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Spain, ROA (Real Instituto y Observatorio de la Armada)
Time scale difference , Time scale difference : -1 s to 1 s
Local clock vs UTC
Absolute expanded uncertainty : 4 ns
Time interval measurement
Averaging time : 5 days
Fractional part of modulo 1 s, integer part can be provided
Approved on 26 July 2019
Institute service identifier : ROA 1.1.2
CMC ID : EURAMET-TF-ES-00000JI4-1
 
Frequency , Frequency : 5 MHz
Local frequency standard
Relative expanded uncertainty : 3.2E-15 Hz/Hz to 1.0E-13 Hz/Hz
U = 1E-13/t1/2 U in Hz/Hz, t in s
Dual mixer time difference
Averaging time : 1 s to 1000 s
Amplitude : >1 V
Frequency instability measurement.
Approved on 26 July 2019
Institute service identifier : ROA 2.4.1
CMC ID : EURAMET-TF-ES-00000JIQ-4
 
Frequency , Frequency : 1 Hz
Remote frequency standard
Relative expanded uncertainty : 2.5E-14 Hz/Hz
GPS common view comparisons
Averaging time : 1 day
Institute service identifier : ROA 2.1.2
CMC ID : EURAMET-TF-ES-00000JID-3
 
Frequency , Frequency : 1.00E-3 Hz to 1000 Hz
General frequency source
Relative expanded uncertainty : 2.0E-12 Hz/Hz to 2.0E-6 Hz/Hz
U = 2E-09/f U in Hz/Hz, f in Hz
Frequency measurement
Averaging time : 1000 s
For square wave signal
Approved on 01 March 2024
Institute service identifier : ROA 2.2.1-I
CMC ID : EURAMET-TF-ES-00000O0O-1
 
Time scale difference , Time scale difference : -1 s to 1 s
Remote clock vs UTC
Absolute expanded uncertainty : 8 ns
GPS common view comparisons
Averaging time : 5 days
Fractional part of modulo 1 second difference, integer part can be provided also
Approved on 26 July 2019
Institute service identifier : ROA 1.2.2
CMC ID : EURAMET-TF-ES-00000JI7-1
 
Frequency , Frequency : 10 MHz
Local frequency standard
Relative expanded uncertainty : 1.5E-14 Hz/Hz
Phase/time measurement
Averaging time : 1 day
Approved on 26 July 2019
Institute service identifier : ROA 2.1.1
CMC ID : EURAMET-TF-ES-00000JIB-1
 
Time interval , Time interval : 1.00E-8 s to 1 s
Pulse width source
Absolute expanded uncertainty : 1 ns
Time interval counter
Slew rate : > 0.1 V/ns
Approved on 26 July 2019
Institute service identifier : ROA 3.2.2
CMC ID : EURAMET-TF-ES-00000JIK-1
 
Time interval , Time interval : 1.00E-7 s to 1 s
Period meter
Absolute expanded uncertainty : 1 ns
Pulse generator
Slew rate : > 0.1 V/ns
Approved on 26 July 2019
Institute service identifier : ROA 3.3.1
CMC ID : EURAMET-TF-ES-00000JIN-1
 
Frequency , Frequency : 1.00E4 Hz to 8.00E7 Hz
Frequency meter
Relative expanded uncertainty : 2.0E-11 Hz/Hz
Direct measurement
Averaging time : 1000 s
For sine wave signal.
Institute service identifier : ROA 2.3.2
CMC ID : EURAMET-TF-ES-00000JIH-2
 
Time interval , Time interval : 1.00E-9 s to 1 s
Delay source
Absolute expanded uncertainty : 1 ns
Time interval counter
Slew rate : > 0.5 V/ns
Institute service identifier : ROA 3.2.4
CMC ID : EURAMET-TF-ES-00000JIM-2
 
Time interval , Time interval : 1.00E-9 s to 1 s
Time difference source
Absolute expanded uncertainty : 0.5 ns
Time interval counter
Slew rate : > 0.5 V/ns
Approved on 01 March 2024
Institute service identifier : ROA 3.2.3
CMC ID : EURAMET-TF-ES-00000JIL-4
 
Time scale difference , Time scale difference : -1 s to 1 s
Local clock vs UTC(ROA)
Absolute expanded uncertainty : 1 ns
Time interval measurement
Pulse amplitude : >1 V
Slew rate : > 1 V/ns
Load impedance : 50 Ω
Trigger level : 1 V
Fractional part of modulo 1 s, integer part can be provided
Approved on 26 July 2019
Institute service identifier : ROA 1.1.1
CMC ID : EURAMET-TF-ES-00000JI2-1
 
Time interval , Time interval : 1.00E-9 s to 1 s
Rise/fall time source
Absolute expanded uncertainty : 1 ns
Time interval counter
Slew rate : > 0.1 V/ns
Approved on 26 July 2019
Institute service identifier : ROA 3.2.1
CMC ID : EURAMET-TF-ES-00000JIJ-1
 
Frequency , Frequency : 5 MHz
Local frequency standard
Relative expanded uncertainty : 1.5E-14 Hz/Hz
Phase/time measurement
Averaging time : 1 day
Approved on 26 July 2019
Institute service identifier : ROA 2.1.1
CMC ID : EURAMET-TF-ES-00000JIA-1
 
Time interval , Time interval : 1.00E-8 s to 1 s
Pulse width meter
Absolute expanded uncertainty : 1 ns
Pulse generator
Slew rate : > 0.1 V/ns
Approved on 26 July 2019
Institute service identifier : ROA 3.4.2
CMC ID : EURAMET-TF-ES-00000JIO-1
 
Frequency , Frequency : 1000 Hz to 1.30E9 Hz
General frequency source
Relative expanded uncertainty : 2.0E-12 Hz/Hz
Frequency measurement
Averaging time : 1000 s
For square wave signal
Approved on 01 March 2024
Institute service identifier : ROA 2.2.1-I
CMC ID : EURAMET-TF-ES-00000O0P-1
 
Time scale difference , Time scale difference : -1 s to 1 s
Remote clock vs UTC
Absolute expanded uncertainty : 1.1E1 ns
GPS common view comparisons
Prediction time : 20 days
Fractional part of modulo 1 s, integer part can be provided
Approved on 26 July 2019
Institute service identifier : ROA 1.2.2
CMC ID : EURAMET-TF-ES-00000JI6-1
 
Time interval , Time interval : 1.00E-9 s to 1000 s
Period source
Absolute expanded uncertainty : 1 ns
Time interval counter
Slew rate : > 0.1 V/ns
Approved on 26 July 2019
Institute service identifier : ROA 3.1.1
CMC ID : EURAMET-TF-ES-00000JII-1
 
Frequency , Frequency : 1 Hz to 1.00E4 Hz
Frequency meter
Relative expanded uncertainty : 2.0E-11 Hz/Hz to 2.0E-7 Hz/Hz
U = 2E-07/f U in Hz/Hz, f in Hz
Direct measurement
Averaging time : 1000 s
For sine wave signal.
Approved on 26 July 2019
Institute service identifier : ROA 2.3.2
CMC ID : EURAMET-TF-ES-00000JIG-3
 
Frequency , Frequency : 10 MHz
Remote frequency standard
Relative expanded uncertainty : 2.5E-14 Hz/Hz
GPS common view comparisons
Averaging time : 1 day
Approved on 26 July 2019
Institute service identifier : ROA 2.1.2
CMC ID : EURAMET-TF-ES-00000JIC-3
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.