Results for: Slovenia "MIRS/UM-FS/LTM"
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
24 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Slovenia, MIRS/UM-FS/LTM (MIRS/University of Maribor, Faculty for Mechanical Engineering/Laboratory for Production Management)
Radiations of the mise en pratique , Laser radiations : 633 nm
Frequency stabilized laser: vacuum wavelength
Absolute expanded uncertainty : 4.0E-2 fm
Optical beat frequency
Approved on 01 April 2010
Institute service identifier : MIRS/UM-FS/LTM-23
CMC ID : EURAMET-L-SI-00000C42-1
 
Form , Flatness standards : 0 µm to 100 µm
Surface plates: flatness
Absolute expanded uncertainty : 0.3 µm to 0.7 µm
Q[0.3 µm, 0.2E-06 L]
Electronic levels
Maximum length L : 3 m
Maximum width : 2 m
Approved on 14 September 2018
Institute service identifier : MIRS/UM-FS/LTM-17
CMC ID : EURAMET-L-SI-00000C48-2
 
Linear dimensions , Diameter standards : 0.1 mm to 10 mm
External cylinder (pins or wires): diameter L
Absolute expanded uncertainty : 0.3 µm
Q[0.3 µm, 3E-06 L]
1-D comparator and laser interferometer and 2 flat probes
Approved on 22 March 2005
Institute service identifier : MIRS/UM-FS/LTM-10
CMC ID : EURAMET-L-SI-00000C3Q-2
 
Linear dimensions , End standards : 125 mm to 1000 mm
Length bar (long gauge block): central length L
Absolute expanded uncertainty : 0.16 µm to 1 µm
Q[0.1 µm, 1E-06 L]
1-D comparator and mechanical
Approved on 22 March 2005
Institute service identifier : MIRS/UM-FS/LTM-6
CMC ID : EURAMET-L-SI-00000C3O-2
 
Linear dimensions , Diameter standards : 2 mm to 300 mm
Internal cylinder (ring): diameter L
Absolute expanded uncertainty : 0.2 µm to 0.9 µm
Q[0.2 µm, 2.8E-06 L]
CMM substitution principle
Approved on 14 September 2018
Institute service identifier : MIRS/UM-FS/LTM-11
CMC ID : EURAMET-L-SI-00000C47-2
 
Angle , Angle instruments : -3 mm/m to 3 mm/m
(spirit) bubble levels: inclination angle
Absolute expanded uncertainty : 1.1E1 µm/m
Sine bar, gauge blocks
Approved on 22 March 2005
Institute service identifier : MIRS/UM-FS/LTM-14
CMC ID : EURAMET-L-SI-00000C3T-1
 
Linear dimensions , Length instruments : -10 µm to 10 µm
Gauge block comparator: error of indicated displacement L
Absolute expanded uncertainty : 2.0E1 nm to 4.0E1 nm
20 nm + 0.2E-06 L
Gauge block set
Gauge block length : maximum 100 mm
Approved on 14 September 2018
Institute service identifier : MIRS/UM-FS/LTM-3
CMC ID : EURAMET-L-SI-00000C45-2
 
Linear dimensions , Length instruments : 0 m to 2 m
Height measuring instrument: error of indicated displacement L
Absolute expanded uncertainty : 3.0E-2 µm to 7 µm
Q[0.03 µm, 3.5E-06 L]
Laser interferometer
Approved on 14 September 2018
Institute service identifier : MIRS/UM-FS/LTM-2
CMC ID : EURAMET-L-SI-00000C44-2
 
Complex geometry , Screw standards : 0.5 mm to 50 mm
Thread plugs, plain: pitch
Absolute expanded uncertainty : 0.8 µm
CMM and T stylus
Pitch diameter: :  0.5 mm to 300 mm
Approved on 22 March 2005
Institute service identifier : MIRS/UM-FS/LTM-19
CMC ID : EURAMET-L-SI-00000C3X-2
 
Complex geometry , Screw standards : 1 mm to 300 mm
Thread plugs, plain: pitch diameter L
Absolute expanded uncertainty : 2.5 µm to 2.9 µm
Q[2.5 µm, 4.5E-06 L]
Micrometer and wires, CMM and T stylus (comparator method)
Approved on 22 March 2005
Institute service identifier : MIRS/UM-FS/LTM-18
CMC ID : EURAMET-L-SI-00000C3W-2
 
Linear dimensions , Length instruments : 0 m to 5 m
1-D measuring machine: error of indicated displacement L
Absolute expanded uncertainty : 3.0E-2 µm to 1.8E1 µm
Q[0.03 µm, 3.5E-06 L]
Laser interferometer
Approved on 14 September 2018
Institute service identifier : MIRS/UM-FS/LTM-1
CMC ID : EURAMET-L-SI-00000C43-2
 
Linear dimensions , Line standards : 0 mm to 500 mm
Precision line scale: line spacing L
Absolute expanded uncertainty : 9.0E-2 µm to 0.56 µm
Q[0.09 µm, 1.1E-06 L]
Laser interferometer and CCD microscope
Approved on 14 September 2018
Institute service identifier : MIRS/UM-FS/LTM-25
CMC ID : EURAMET-L-SI-00000C49-2
 
Complex geometry , Screw standards : 6 mm to 300 mm
Thread rings, plain: pitch diameter L
Absolute expanded uncertainty : 2.5 µm to 2.9 µm
Q[2.5 µm, 4.5E-06 L]
CMM and T stylus (comparator method)
Approved on 22 March 2005
Institute service identifier : MIRS/UM-FS/LTM-20
CMC ID : EURAMET-L-SI-00000C3Y-2
 
Linear dimensions , Diameter standards : 1 mm to 300 mm
External cylinder: diameter L
Absolute expanded uncertainty : 0.5 µm to 1 µm
Q[0.5 µm, 3E-06 L]
1-D comparator and laser interferometer and 2 flat probes, gauge substitution
Approved on 22 March 2005
Institute service identifier : MIRS/UM-FS/LTM-9
CMC ID : EURAMET-L-SI-00000C3P-2
 
Linear dimensions , Line standards : 0 m to 200 m
(surveyor, engineer) tape: line spacing L
Absolute expanded uncertainty : 1.0E1 µm to 2.5E3 µm
10 µm + 12.5E-06 L
Laser interferometer and CCD microscope
Approved on 14 September 2018
Institute service identifier : MIRS/UM-FS/LTM-8
CMC ID : EURAMET-L-SI-00000C46-2
 
Linear dimensions , End standards : 0.5 mm to 100 mm
Gauge block: central length L
Absolute expanded uncertainty : 3.5E1 nm to 6.1E1 nm
Q[35 nm, 0.5E-06 L]
Mechanical comparison
Approved on 14 September 2010
Institute service identifier : MIRS/UM-FS/LTM-5
CMC ID : EURAMET-L-SI-00000C3N-2
 
Radiations of the mise en pratique , Laser radiations : 633 nm
Frequency stabilized laser: vacuum wavelength
Relative expanded uncertainty : 1.0E-9
Optical beat frequency
Approved on 01 April 2010
Institute service identifier : MIRS/UM-FS/LTM-24
CMC ID : EURAMET-L-SI-00000C4A-1
 
Radiations of the mise en pratique , Laser radiations : 474 THz
Frequency stabilized laser: absolute frequency
Absolute expanded uncertainty : 2.4E1 kHz
Optical beat frequency
Approved on 01 April 2010
Institute service identifier : MIRS/UM-FS/LTM-23
CMC ID : EURAMET-L-SI-00000C41-1
 
Complex geometry , Screw standards : 0.5 mm to 50 mm
Thread rings, plain: pitch
Absolute expanded uncertainty : 0.8 µm
CMM and T stylus
Pitch diameter: : 6 mm to 300 mm
Approved on 22 March 2005
Institute service identifier : MIRS/UM-FS/LTM-21
CMC ID : EURAMET-L-SI-00000C3Z-2
 
Angle , Angle artifacts : 90 °
90° cylinder: squareness
Absolute expanded uncertainty : 0.9 second
CMM
Maximum length : 500 mm
Maximum diameter : 300 mm
Approved on 22 March 2005
Institute service identifier : MIRS/UM-FS/LTM-16
CMC ID : EURAMET-L-SI-00000C3V-2
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.