Results for: Slovenia "MIRS/UL-FE/LMK"
Filters
CMC Quick search Filters close;
CMC Area
To filter, either use the tick boxes or click on the underscored item
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Slovenia, MIRS/UL-FE/LMK (MIRS/University of Ljubljana, Faculty of Electrical Engineering/Laboratory of Metrology and Quality)
Items for disseminating ITS-90 and PLTS 2000 ,
Temperature
:
150 °C to 300 °C
Platinum Resistance Thermometer
Absolute expanded uncertainty
:
6 mK
Comparison in oil bath
Ambient temperature : 23 °C
Approved on 03 November 2009
Institute service identifier : MIRS/UL-FE/LMK/2.2.2 PRT
CMC ID :
EURAMET-T-SI-00000BQU-1
Items for disseminating ITS-90 and PLTS 2000 ,
Temperature
:
1084.62 °C
Noble metal thermocouple (type R/S)
Absolute expanded uncertainty
:
0.6 K
Fixed point
Ambient temperature : 23 °C
Approved on 03 November 2009
Institute service identifier : MIRS/UL-FE/LMK/2.3.1. TC
CMC ID :
EURAMET-T-SI-00000BR3-1
Items for disseminating ITS-90 and PLTS 2000 ,
Temperature
:
660.323 °C
Noble metal thermocouple (type R/S)
Absolute expanded uncertainty
:
0.3 K
Fixed point
Ambient temperature : 23 °C
Approved on 03 November 2009
Institute service identifier : MIRS/UL-FE/LMK/2.3.1. TC
CMC ID :
EURAMET-T-SI-00000BR1-1
Items for disseminating ITS-90 and PLTS 2000 ,
Temperature
:
-196 °C
Platinum Resistance Thermometer
Absolute expanded uncertainty
:
1.0E-2 °C
Comparison in liquid cryostat
Stirred liquid cryostat : Boiling point of nitrogen
Approved on 10 November 2015
Institute service identifier : MIRS/UL-FE/LMK/2.2.2. PRT
CMC ID :
EURAMET-T-SI-00000BQF-1
Items for disseminating ITS-90 and PLTS 2000 ,
Temperature
:
-196 °C to -98 °C
Base metal thermocouple (T,K,N)
Absolute expanded uncertainty
:
0.5 °C
Comparison in liquid cryostat
Stirred liquid bath : Comparison cryostat
Approved on 10 November 2015
Institute service identifier : MIRS/UL-FE/LMK/2.3.1. TC
CMC ID :
EURAMET-T-SI-00000BQH-1
Items for disseminating ITS-90 and PLTS 2000 ,
Temperature
:
250 °C to 300 °C
Noble metal thermocouple (type R/S)
Absolute expanded uncertainty
:
0.15 K
Comparison in oil bath
Ambient temperature : 23 °C
Approved on 19 March 2012
Institute service identifier : MIRS/UL-FE/LMK/2.3.1. TC
CMC ID :
EURAMET-T-SI-00000BPZ-1
Items for defining ITS-90 ,
Temperature
:
419.527 °C
Long-stem SPRT
Absolute expanded uncertainty
:
1.5 mK
Fixed point (zinc)
Ambient temperature : 23 °C
Approved on 18 May 2004
Institute service identifier : MIRS/UL-FE/LMK/1.3.2 Zn
CMC ID :
EURAMET-T-SI-00000BQO-1
Items for defining ITS-90 ,
Temperature
:
660.323 °C
Long-stem SPRT
Absolute expanded uncertainty
:
2.5 mK
Fixed point
Ambient temperature : 23 °C
Approved on 20 May 2010
Institute service identifier : MIRS/UL-FE/LMK/1.3.2 Al
CMC ID :
EURAMET-T-SI-00000BPX-1
Items for defining ITS-90 ,
Temperature
:
156.5985 °C
Freezing point of Indium
Absolute expanded uncertainty
:
0.9 mK
Direct comparison
Temperature-controlled bath
Approved on 18 May 2004
Institute service identifier : MIRS/UL-FE/LMK/1.1.1 In
CMC ID :
EURAMET-T-SI-00000BQI-1
Hygrometers ,
Humidity
:
10 %rh to 95 %rh
Relative humidity sensors
Absolute expanded uncertainty
:
1.2 %rh
Calibration by comparison
Ambient temperature : -10 °C to 0 °C
Approved on 05 May 2014
CMC ID :
EURAMET-T-SI-00000BQA-1
Items for disseminating ITS-90 and PLTS 2000 ,
Temperature
:
125 °C to 150 °C
Liquid-in-glass thermometer
Absolute expanded uncertainty
:
4.0E-2 K
Comparison in oil bath
Ambient temperature : 23 °C
Approved on 03 November 2009
Institute service identifier : MIRS/UL-FE/LMK/2.4. LIGT
CMC ID :
EURAMET-T-SI-00000BPO-1
Items for disseminating ITS-90 and PLTS 2000 ,
Temperature
:
150 °C to 250 °C
Liquid-in-glass thermometer
Absolute expanded uncertainty
:
4.0E-2 K
Comparison in oil bath
Ambient temperature : 23 °C
Approved on 03 November 2009
Institute service identifier : MIRS/UL-FE/LMK/2.4. LIGT
CMC ID :
EURAMET-T-SI-00000BPP-1
Items for disseminating ITS-90 and PLTS 2000 ,
Temperature
:
70 °C to 125 °C
Liquid-in-glass thermometer
Absolute expanded uncertainty
:
8.0E-3 K
Comparison in oil bath
Ambient temperature : 23 °C
Approved on 03 November 2009
Institute service identifier : MIRS/UL-FE/LMK/2.4. LIGT
CMC ID :
EURAMET-T-SI-00000BPN-1
Items for disseminating ITS-90 and PLTS 2000 ,
Temperature
:
-196 °C to -98 °C
Platinum Resistance Thermometer
Absolute expanded uncertainty
:
3.0E-2 °C
Comparison in liquid cryostat
Stirred liquid cryostat : Comparison cryostat
Approved on 10 November 2015
Institute service identifier : MIRS/UL-FE/LMK/2.2.2. PRT
CMC ID :
EURAMET-T-SI-00000BQG-1
Items for disseminating ITS-90 and PLTS 2000 ,
Temperature
:
600 °C to 1000 °C
Noble metal thermocouple (type R/S)
Absolute expanded uncertainty
:
0.4 K
Comparison in Na heat pipe
Ambient temperature : 23 °C
Approved on 19 March 2012
Institute service identifier : MIRS/UL-FE/LMK/2.3.1. TC
CMC ID :
EURAMET-T-SI-00000BQ1-1
Items for disseminating ITS-90 and PLTS 2000 ,
Temperature
:
10 °C to 70 °C
Platinum Resistance Thermometer
Absolute expanded uncertainty
:
6 mK
Comparison in water bath
Ambient temperature : 23 °C
Approved on 03 November 2009
Institute service identifier : MIRS/UL-FE/LMK/2.2.2 PRT
CMC ID :
EURAMET-T-SI-00000BQS-1
Items for disseminating ITS-90 and PLTS 2000 ,
Temperature
:
10 °C to 70 °C
Liquid-in-glass thermometer
Absolute expanded uncertainty
:
8.0E-3 K
Comparison in water bath
Ambient temperature : 23 °C
Approved on 03 November 2009
Institute service identifier : MIRS/UL-FE/LMK/2.4. LIGT
CMC ID :
EURAMET-T-SI-00000BRB-1
Items for disseminating ITS-90 and PLTS 2000 ,
Temperature
:
231.928 °C
Noble metal thermocouple (type R/S)
Absolute expanded uncertainty
:
0.3 K
Fixed point
Ambient temperature : 23 °C
Approved on 03 November 2009
Institute service identifier : MIRS/UL-FE/LMK/2.3.1. TC
CMC ID :
EURAMET-T-SI-00000BQZ-1
Items for defining ITS-90 ,
Temperature
:
0.01 °C
Long-stem SPRT
Absolute expanded uncertainty
:
0.15 mK
Calibration at water triple point
Ambient temperature : 23 °C
Approved on 20 January 2010
Institute service identifier : MIRS/UL-FE/LMK/1.3.2 W
CMC ID :
EURAMET-T-SI-00000BPS-1
Items for defining ITS-90 ,
Temperature
:
961.78 °C
Long-stem SPRT
Absolute expanded uncertainty
:
1.5E1 mK
Fixed point
Ambient temperature : 23 °C
Approved on 20 May 2010
Institute service identifier : MIRS/UL-FE/LMK/1.3.2 Ag
CMC ID :
EURAMET-T-SI-00000BPY-1