Results for: Portugal "IST-LPSR"
Filters
CMC Quick search Filters close;
CMC Area
To filter, either use the tick boxes or click on the underscored item
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Portugal, IST-LPSR (Laboratório de Proteção e Segurança Radiológica, Instituto Superior Técnico)
Ionizing radiation
Personal dose equivalent/rate, superficial
,
Radiation protection dosemeter
: 3.00E-3 mSv/h to 520 mSv/h
Relative expanded uncertainty 4.7 %
Calibration against a transfer standard
X-ray, 10 kV to 50 kV, ISO-4037 Narrow spectra, 30 kV to 40 kV
Reference standard : Secondary standard ionisation chamber
Source of traceability : PTB
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1041
CMC ID :
EURAMET-RI-PT-00000JGU-1
Ionizing radiation
Personal dose equivalent/rate, superficial
,
Radiation protection dosemeter
: 3.50E-4 mSv/h to 2.40E4 mSv/h
Relative expanded uncertainty 4.2 %
Calibration against a transfer standard
Co-60, ISO-4037
Reference standard : Primary standard graphite cavity ionisation chamber
Source of traceability : IST-LPSR - DPRSN
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1039
CMC ID :
EURAMET-RI-PT-00000JGS-1
Ionizing radiation
Directional dose equivalent/rate
,
Reference dosemeter
: 3.00E-3 mSv/h to 520 mSv/h
Relative expanded uncertainty 4.4 %
Calibration against a secondary standard
X-ray, 50 kV to 420 kV, ISO-4037 Narrow spectra, 60 kV to 300 kV
Reference standard : Secondary standard ionisation chambers
Source of traceability : PTB
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1022
CMC ID :
EURAMET-RI-PT-00000JGB-1
Ionizing radiation
Directional dose equivalent/rate
,
Reference dosemeter
: 3.00E-3 mSv/h to 520 mSv/h
Relative expanded uncertainty 4.7 %
Calibration against a secondary standard
X-ray, 10 kV to 50 kV, ISO-4037 Narrow spectra, 30 kV to 40 kV
Reference standard : Secondary standard ionisation chamber
Source of traceability : PTB
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1021
CMC ID :
EURAMET-RI-PT-00000JGA-1
Ionizing radiation
Ambient dose equivalent/rate
,
Reference dosemeter
: 3.00E-3 mSv/h to 520 mSv/h
Relative expanded uncertainty 4.4 %
Calibration against a secondary standard
X-ray, 50 kV to 420 kV, ISO-4037 Narrow spectra, 60 kV to 300 kV
Reference standard : Secondary standard ionisation chambers
Source of traceability : PTB
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1017
CMC ID :
EURAMET-RI-PT-00000JG6-1
Ionizing radiation
Personal dose equivalent/rate, superficial
,
Radiation protection dosemeter
: 7.30E-4 mSv/h to 130 mSv/h
Relative expanded uncertainty 4.5 %
Calibration against a transfer standard
Cs-137, ISO-4037
Reference standard : Secondary standard ionisation chamber
Source of traceability : PTB
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1040
CMC ID :
EURAMET-RI-PT-00000JGT-1
Ionizing radiation
Ambient dose equivalent/rate
,
Radiation protection dosemeter
: 7.20E-4 mSv/h to 130 mSv/h
Relative expanded uncertainty 4.5 %
Calibration against a transfer standard
Cs-137, ISO-4037
Reference standard : Secondary standard ionisation chamber
Source of traceability : PTB
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1025
CMC ID :
EURAMET-RI-PT-00000JGE-1
Ionizing radiation
Kerma/rate
,
Radiotherapy dosemeter
: 3.60E-4 Gy/s to 5.70E-3 Gy/s
Relative expanded uncertainty 1.2 %
Calibration against a secondary standard
Co-60, ISO-4037
Reference standard : Primary standard graphite cavity ionisation chamber
Source of traceability : IST-LPSR - DPRSN
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1006
CMC ID :
EURAMET-RI-PT-00000JH1-1
Ionizing radiation
Ambient dose equivalent/rate
,
Radiation protection dosemeter
: 7.00E-3 mSv/h to 1300 mSv/h
Relative expanded uncertainty 4.4 %
Calibration against a transfer standard
X-ray, 50 kV to 420 kV, ISO-4037 Wide spectra, 60 kV to 300 kV
Reference standard : Secondary standard ionisation chambers
Source of traceability : PTB
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1028
CMC ID :
EURAMET-RI-PT-00000JGH-1
Ionizing radiation
Ambient dose equivalent/rate
,
Radiation protection dosemeter
: 3.00E-3 mSv/h to 520 mSv/h
Relative expanded uncertainty 4.7 %
Calibration against a transfer standard
X-ray, 10 kV to 50 kV, ISO-4037 Narrow spectra, 30 kV to 40 kV
Reference standard : Secondary standard ionisation chamber
Source of traceability : PTB
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1026
CMC ID :
EURAMET-RI-PT-00000JGF-1
Ionizing radiation
Ambient dose equivalent/rate
,
Reference dosemeter
: 7.00E-3 mSv/h to 1300 mSv/h
Relative expanded uncertainty 4.4 %
Calibration against a secondary standard
X-ray, 50 kV to 420 kV, ISO-4037 Wide spectra, 60 kV to 300 kV
Reference standard : Secondary standard ionisation chambers
Source of traceability : PTB
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1018
CMC ID :
EURAMET-RI-PT-00000JG7-1
Ionizing radiation
Ambient dose equivalent/rate
,
Reference dosemeter
: 3.00E-3 mSv/h to 520 mSv/h
Relative expanded uncertainty 4.7 %
Calibration against a secondary standard
X-ray, 10 kV to 50 kV, ISO-4037 Narrow spectra, 30 kV to 40 kV
Reference standard : Secondary standard ionisation chamber
Source of traceability : PTB
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1016
CMC ID :
EURAMET-RI-PT-00000JG5-1
Ionizing radiation
Personal dose equivalent/rate, superficial
,
Radiation protection dosemeter
: 3.00E-3 mSv/h to 520 mSv/h
Relative expanded uncertainty 4.4 %
Calibration against a transfer standard
X-ray, 50 kV to 420 kV, ISO-4037 Narrow spectra, 60 kV to 300 kV
Reference standard : Secondary standard ionisation chambers
Source of traceability : PTB
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1042
CMC ID :
EURAMET-RI-PT-00000JGV-1
Ionizing radiation
Personal dose equivalent/rate, penetrating
,
Radiation protection dosemeter
: 3.00E-3 mSv/h to 520 mSv/h
Relative expanded uncertainty 4.4 %
Calibration against a transfer standard
X-ray, 50 kV to 420 kV, ISO-4037 Narrow spectra, 60 kV to 300 kV
Reference standard : Secondary standard ionisation chambers
Source of traceability : PTB
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1037
CMC ID :
EURAMET-RI-PT-00000JGQ-1
Ionizing radiation
Directional dose equivalent/rate
,
Radiation protection dosemeter
: 7.00E-3 mSv/h to 1300 mSv/h
Relative expanded uncertainty 4.4 %
Calibration against a transfer standard
X-ray, 50 kV to 420 kV, ISO-4037 Wide spectra, 60 kV to 300 kV
Reference standard : Secondary standard ionisation chambers
Source of traceability : PTB
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1033
CMC ID :
EURAMET-RI-PT-00000JGM-1
Ionizing radiation
Absorbed dose/rate to water
,
Radiotherapy dosemeter
: 1.00E-4 Gy/s to 2.00E-3 Gy/s
Relative expanded uncertainty 4.8 %
Calibration in water phantom against a secondary standard
X-ray, 50 kV to 420 kV, DIN-6817, 70 kV to 280 kV
Reference standard : Secondary standard ionisation chamber
Source of traceability : PTB
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1003
CMC ID :
EURAMET-RI-PT-00000JGZ-1
Ionizing radiation
Ambient dose equivalent/rate
,
Reference dosemeter
: 3.50E-4 mSv/h to 2.30E4 mSv/h
Relative expanded uncertainty 4.2 %
Calibration against a secondary standard
Co-60, ISO-4037
Reference standard : Primary standard graphite cavity ionisation chamber
Source of traceability : IST-LPSR - DPRSN
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1014
CMC ID :
EURAMET-RI-PT-00000JH9-1
Ionizing radiation
Kerma/rate
,
Radiotherapy dosemeter
: 5.00E-4 Gy/s to 7.00E-3 Gy/s
Relative expanded uncertainty 1.6 %
Calibration against a secondary standard
X-ray, 50 kV to 420 kV, DIN-6817, 70 kV to 280 kV
Reference standard : Secondary standard ionisation chambers
Source of traceability : PTB
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1010
CMC ID :
EURAMET-RI-PT-00000JH5-1
Ionizing radiation
Kerma/rate
,
Radiation protection dosemeter
: 5.00E-3 mGy/h to 1000 mGy/h
Relative expanded uncertainty 1.8 %
Calibration against a transfer standard
X-ray, 50 kV to 420 kV, ISO-4037 Narrow spectra, 60 kV to 300 kV
Reference standard : Secondary standard ionisation chambers
Source of traceability : PTB
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1012
CMC ID :
EURAMET-RI-PT-00000JH7-1
Ionizing radiation
Personal dose equivalent/rate, penetrating
,
Radiation protection dosemeter
: 7.00E-3 mSv/h to 1300 mSv/h
Relative expanded uncertainty 4.4 %
Calibration against a transfer standard
X-ray, 50 kV to 420 kV, ISO-4037 Wide spectra, 60 kV to 300 kV
Reference standard : Secondary standard ionisation chambers
Source of traceability : PTB
Approved on 01 March 2005
Institute service identifier : EUR-RAD-IST-LPSR-1038
CMC ID :
EURAMET-RI-PT-00000JGR-1