Results for: Serbia
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
74 results
Reset all
CMC Area
To filter, either use the tick boxes or click on the underscored item
General physics
Chemical material
Chemical Analyte
Geographical location
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Serbia, DMDM (Directorate of Measures and Precious Metals)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/g Relative expanded uncertainty in % Mass fraction in % Absolute expanded uncertainty in %
water ethanol 0.1 to 8 1.4
  • Mechanism for measurement service delivery : Calibration
  • Approved on 16 September 2023
  • Institute service identifier : RU-H12
  • CMC ID : EURAMET-QM-RS-00000O9A-1
     
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in nmol/mol Absolute expanded uncertainty in nmol/mol Amount-of-substance fraction in % Absolute expanded uncertainty in %
purified air ozone 0 to 1000 1.1 to 2.2E1
  • Uncertainty equation CMC : Q[1.1, 0.022 x(O3)] The uncertainty is expressed in nmol/mol
  • Mechanism for measurement service delivery : Calibration
  • Approved on 28 June 2016
  • Institute service identifier : GMH-RU-H09
  • CMC ID : EURAMET-QM-RS-000000VQ-3
     
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -40 °C to 20 °C
Liquid-in-glass thermometer resolution 0.1 °C
Absolute expanded uncertainty : 3.3E-2 °C
Calibration by comparison
Ethanol bath
Approved on 03 November 2009
Institute service identifier : DMDM/T06-4
CMC ID : EURAMET-T-RS-00000BDN-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -40 °C to 20 °C
Liquid-in-glass thermometer resolution 1 °C
Absolute expanded uncertainty : 0.35 °C
Calibration by comparison
Ethanol bath
Approved on 03 November 2009
Institute service identifier : DMDM/T06-7
CMC ID : EURAMET-T-RS-00000BDQ-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -40 °C to 20 °C
Platinum Resistance Thermometer
Absolute expanded uncertainty : 9.0E-3 °C
Calibration by comparison
Ethanol bath
Approved on 03 November 2009
Institute service identifier : DMDM/T02-1
CMC ID : EURAMET-T-RS-00000BDH-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 300 °C to 600 °C
Base-metal thermocouple
Absolute expanded uncertainty : 0.51 °C to 0.87 °C
Calibration by comparison
Comparison furnace
Approved on 19 March 2012
Institute service identifier : DMDM/T04-5
CMC ID : EURAMET-T-RS-00000BDY-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 600 °C to 1000 °C
Base-metal thermocouple
Absolute expanded uncertainty : 0.87 °C to 1.5 °C
Calibration by comparison
Comparison furnace
Approved on 19 March 2012
Institute service identifier : DMDM/T04-6
CMC ID : EURAMET-T-RS-00000BDZ-1
 
Items for defining ITS-90 , Temperature : -38.8344 °C
Long SPRT in Mercury triple point
Absolute expanded uncertainty : 1 mK
Direct comparison
Ethanol bath
Approved on 17 January 2013
Institute service identifier : DMDM/T01-2
CMC ID : EURAMET-T-RS-00000BDC-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -80 °C to -40 °C
Liquid-in-glass thermometer resolution 0.1 °C
Absolute expanded uncertainty : 3.5E-2 °C
Calibration by comparison
Halocarbon bath
Approved on 19 March 2012
Institute service identifier : DMDM/T06-11
CMC ID : EURAMET-T-RS-00000BE3-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 90 °C to 250 °C
Temperature sensor with display unit
Absolute expanded uncertainty : 2.0E1 mK
Calibration by comparison
Oil bath
Approved on 19 March 2012
Institute service identifier : DMDM/T05-4
CMC ID : EURAMET-T-RS-00000BE8-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -80 °C to -40 °C
Platinum Resistance Thermometer
Absolute expanded uncertainty : 1.0E1 mK
Calibration by comparison
Halocarbon bath
Approved on 19 March 2012
Institute service identifier : DMDM/T02-4
CMC ID : EURAMET-T-RS-00000BE0-1
 
Hygrometers , Relative humidity : 11 %rh to 95 %rh
Relative humidity sensors
Absolute expanded uncertainty : 0.5 %rh to 1.6 %rh
Comparison inside the chamber of 2t/2p generator by measurement of dew/frost point and temperature
temperature  : from 10 oC to 20  oC
Approved on 02 December 2020
Institute service identifier : RH01-1
CMC ID : EURAMET-T-RS-00000JU3-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 1084.62 °C
Termocouples- S and R type
Absolute expanded uncertainty : 0.4 °C
Direct comparison 
Tree zone furnace for fixed pooint realization : Tree zone furnace for fixed pooint realization
Approved on 02 December 2020
Institute service identifier : T03-1
CMC ID : EURAMET-T-RS-00000JTU-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : -196 °C
Industrial resistance thermometer
Absolute expanded uncertainty : 1.6E1 mK
Compariosn methods with SPRT 
Declared uncertatinty is at single temperature point, interpolation error is not part of uncertainty.
Approved on 13 August 2020
Institute service identifier : T02-6
CMC ID : EURAMET-T-RS-00000JU1-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 660.323 °C
Termocouples- S and R type
Absolute expanded uncertainty : 0.25 °C
Direct comparison 
Approved on 02 December 2020
Institute service identifier : T03-1
CMC ID : EURAMET-T-RS-00000JTS-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 90 °C to 250 °C
Liquid-in-glass thermometer resolution 0.1 °C
Absolute expanded uncertainty : 3.4E-2 °C
Calibration by comparison
Oil bath
Approved on 03 November 2009
Institute service identifier : DMDM/T06-6
CMC ID : EURAMET-T-RS-00000BDP-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 20 °C to 90 °C
Liquid-in-glass thermometer resolution 1 °C
Absolute expanded uncertainty : 0.35 °C
Calibration by comparison
Water bath
Approved on 03 November 2009
Institute service identifier : DMDM/T06-8
CMC ID : EURAMET-T-RS-00000BDR-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 20 °C to 90 °C
Platinum Resistance Thermometer
Absolute expanded uncertainty : 8.0E-3 °C
Calibration by comparison
Water bath
Approved on 03 November 2009
Institute service identifier : DMDM/T02-2
CMC ID : EURAMET-T-RS-00000BDI-1
 
Items for defining ITS-90 , Temperature : 29.7646 °C
Long SPRT in Galium melting point
Absolute expanded uncertainty : 1 mK
Direct comparison
Water bath
Approved on 17 January 2013
Institute service identifier : DMDM/T01-3
CMC ID : EURAMET-T-RS-00000BDD-1
 
Items for disseminating ITS-90 and PLTS 2000 , Temperature : 100 °C to 300 °C
Base-metal thermocouple
Absolute expanded uncertainty : 0.51 °C
Calibration by comparison
Comparison furnace
Approved on 19 March 2012
Institute service identifier : DMDM/T04-4
CMC ID : EURAMET-T-RS-00000BDX-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.