Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (53)
CMCs Chemistry (4)
PHYSICS
Temperature (36)
Frequency (11)
Force (2)
Time interval (1)
Dimensional metrology (1)
Density (1)
Humidity (1)
CHEMICAL MATERIAL
aqueous solution (3)
aqueous pH buffer (1)
GEOGRAPHIC LOCATION
SIM (57)
Colombia (57)
Result of the search
Your query 'colombia' produced 57 results New search
1  2  3

 
Colombia, INM (CO) (Instituto Nacional de Metrologa de Colombia)
Complete CMCs in Thermometry for Colombia (.PDF file)
Temperature. Platinum Resistance Thermometer, 0 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 0.013
Ice point bath
Temperature: 21 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-04
 
Temperature. Platinum Resistance Thermometer, -80 C to 0 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 0.072
Comparison in stirred ethanol bath
Temperature: 21 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-05
 
Temperature. Platinum Resistance Thermometer, 0 C to 150 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 0.044
Comparison in stirred water and oil baths
Temperature: 21 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-06
 
Temperature. Platinum Resistance Thermometer, 50 C to 100 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 0.120
Comparison in metal block furnace
Temperature: 21 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-07
 
Temperature. Platinum Resistance Thermometer, 100 C to 200 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 0.220
Comparison in metal block furnace
Temperature: 21 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-08
 
Temperature. Platinum Resistance Thermometer, 200 C to 300 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 0.320
Comparison in metal block furnace
Temperature: 21 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-09
 
Temperature. Platinum Resistance Thermometer, 300 C to 419.5 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 0.440
Comparison in metal block furnace
Temperature: 21 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-10
 
Temperature. thermocouple: noble metal (types S, R and B), 0 C to 400 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 0.12 to 1.2
Comparison ice point and metal tube, and block furnace
Temperature: 21 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-11
 
Temperature. thermocouple: noble metal (types S, R and B), 400 C to 800 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 1.2 to 2.4
Comparison metal tube, and block furnace
Temperature: 21 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-12
 
Temperature. thermocouple: noble metal, (types S, R and B), 800 C to 1200 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 2.4 to 3.3
Comparison metal tube, and block furnace
Temperature: 21 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-13
 
Temperature. Liquid-in-glass thermometer: 0.05 C graduation, total immersion, Mercury , -38 C to 5 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 0.048
Comparison in stirred liquid bath
Temperature: 21 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-14
 
Temperature. Liquid-in-glass thermometer: 0.1 C graduation, total immersion, Mercury, -38 C to 5 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 0.049
Comparison in stirred liquid bath
Temperature: 21 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-15
 
Temperature. Liquid-in-glass thermometer: 0.2 C graduation, total immersion, Mercury, -38 C to 5 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 0.056
Comparison in stirred liquid bath
Temperature: 21 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-16
 
Temperature. Liquid-in-glass thermometer: 0.5 C graduation, total immersion, Mercury, -38 C to 5 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 0.092
Comparison in stirred liquid bath
Temperature: 21 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-17
 
Temperature. Liquid-in-glass thermometer: 1 C graduation, total immersion, Mercury, -38 C to 5 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 0.17
Comparison in stirred liquid bath
Temperature: 21 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-18
 
Temperature. Liquid-in-glass thermometer: 0.05 C graduation, total immersion, Mercury, 5 C to 80 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 0.037
Comparison in stirred liquid bath
Temperature: 20 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-19
 
Temperature. Liquid-in-glass thermometer: 0.1 C graduation, 5 C to 80 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 0.039
Comparison in stirred liquid bath
Temperature: 21 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-20
 
Temperature. Liquid-in-glass thermometer: 0.2 C graduation, 5 C to 80 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 0.048
Comparison in stirred liquid bath
Temperature: 21 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-21
 
Temperature. Liquid-in-glass thermometer: 0.5 C graduation, total immersion, Mercury, 5 C to 80 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 0.089
Comparison in stirred liquid bath
Temperature: 21 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-22
 
Temperature. Liquid-in-glass thermometer: 1 C graduation, total immersion, Mercury, 5 C to 80 C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in C: 0.17
Comparison in stirred liquid bath
Temperature: 21 C ± 2 C
Relative humidity: 50 %RH ± 15 %RH
Approved on 23 October 2015
Internal NMI service identifier: INM-L02-23