CMC AREA
CMCs General Physics (85)
CMCs Ionizing Radiation (2)
PHYSICS
Temperature (29)
Dimensional metrology (19)
DC voltage, current, and resistance (16)
Pressure (10)
AC voltage, current, and power (4)
Laser frequencies (3)
Humidity (3)
Impedance up to the MHz range (1)
IONIZING RADIATION
Air kerma rate (1)
Absorbed dose rate to water (1)
GEOGRAPHIC LOCATION
EURAMET (87)
Croatia (87)
Result of the search
Your query 'Croatia' produced 87 results New search
[Prev] 2  3  4 [Next >>]

 
Croatia, FSB-LPMD (FSB - Laboratory for Precise Measurements of Length)
Complete CMCs in Length for Croatia (.PDF file)
Line standards. Precision line scale: line spacing L, 0 mm to 300 mm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in nm: (150 + L), L in mm
Laser interferometer and CCD microscope
Approved on 03 August 2011
Internal NMI service identifier: FSB-LPMD/9
 
End standards. Gauge block: central length L, 0.5 mm to 100 mm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in nm: Q[30, 0.5L], L in mm
Interferometry exact fractions
Approved on 08 October 2012
Internal NMI service identifier: FSB-LPMD/20
 
Roundness standards. External cylinder (plug): roundness, R, 0 Ám to 100 Ám
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in nm: Q[110, 20R], R in Ám
Form tester stylus instrument
Diameter: 8 mm to 200 mm
Approved on 08 October 2012
Internal NMI service identifier: FSB-LPMD/12
 
Roundness standards. Internal cylinder (ring): roundness, R, 0 Ám to 100 Ám
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in nm: Q[110, 20R], R in Ám
Form tester stylus instrument
Diameter: 8 mm to 200 mm
Approved on 08 October 2012
Internal NMI service identifier: FSB-LPMD/13
 
Roundness standards. Hemisphere: roundness, R, 0 Ám to 3 Ám
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in nm: Q[90, 20R], R in Ám
Form tester stylus instrument
Diameter: 8 mm to 200 mm
Approved on 08 October 2012
Internal NMI service identifier: FSB-LPMD/14
 
Screw standards. Thread plugs, plain; simple pitch diameter, 1 mm to 60 mm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Ám: 3.0
3 wire method, length measuring machine
Pitch: 0.25 mm to 6 mm
Approved on 20 February 2013
Internal NMI service identifier: FSB-LPMD/6
 
Screw standards. Thread rings, plain; simple pitch diameter, 4 mm to 60 mm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Ám: 3.0
Two-ball stylus, length measuring machine
Pitch: 0.6 mm to 6 mm
Approved on 20 February 2013
Internal NMI service identifier: FSB-LPMD/7
 
Screw standards. Thread plug, plain; pitch diameter, 1 mm to 60 mm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Ám: 3.0
3 wire method, length measuring machine
Pitch: 0.25 mm to 6 mm
Approved on 12 September 2016
Internal NMI service identifier: FSB-LPMD/21
 
Screw standards. Thread ring, plain; pitch diameter, 4 mm to 60 mm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Ám: 3.0
Two-ball stylus, length measuring machine
Pitch: 0.6 mm to 6 mm
Approved on 12 September 2016
Internal NMI service identifier: FSB-LPMD/22
 
Screw standards. Thread plug, plain; pitch, 0.25 mm to 6 mm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Ám: 1.7
Optical, tool microscope
Approved on 12 September 2016
Internal NMI service identifier: FSB-LPMD/23
 
Screw standards. Thread ring, plain; pitch , 0.6 mm to 6 mm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Ám: 1.2
Length measuring machine
Approved on 12 September 2016
Internal NMI service identifier: FSB-LPMD/24
 
Laser radiations. Frequency stabilized laser: vacuum wavelength, 633 nm
Relative expanded uncertainty (k = 2, level of confidence 95 %): 1.0E-09
Optical beat frequency
Approved on 01 April 2010
Internal NMI service identifier: FSB-LPMD/11
 
Croatia, FSB-LPM (FSB - Laboratory for Process Measurements)
Complete CMCs in Thermometry for Croatia (.PDF file)
Temperature. Platinum Resistance Thermometer, 0 ░C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in mK: 8
Comparison with SPRT
Ice point
Approved on 03 November 2009
Internal NMI service identifier: FSB-LPM/2.2.2
 
Temperature. Platinum Resistance Thermometer, -40 ░C to 0 ░C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in mK: 10
Comparison with SPRT
Glycol bath
Approved on 03 November 2009
Internal NMI service identifier: FSB-LPM/2.2.2
 
Temperature. Platinum Resistance Thermometer, 0 ░C to 95 ░C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in mK: 10
Comparison with SPRT
Water bath
Approved on 03 November 2009
Internal NMI service identifier: FSB-LPM/2.2.2
 
Temperature. Platinum Resistance Thermometer, 90 ░C to 180 ░C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in mK: 12
Comparison with SPRT
Oil bath
Approved on 03 November 2009
Internal NMI service identifier: FSB-LPM/2.2.2
 
Temperature. Platinum Resistance Thermometer, 180 ░C to 660 ░C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in mK: 100
Comparison with SPRT
Fluidised bath
Approved on 03 November 2009
Internal NMI service identifier: FSB-LPM/2.2.2
 
Temperature. Noble metal thermocouple, 1084.62 ░C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in K: 0.6
Calibration at Cu freezing point
3-zone furnace
Approved on 03 November 2009
Internal NMI service identifier: FSB-LPM/2.3.1 Cu
 
Temperature. Noble metal thermocouple, 0 ░C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in K: 0.20
Secondary fixed point
Ice point
Approved on 03 November 2009
Internal NMI service identifier: FSB-LPM/2.3.1
 
Temperature. Noble metal thermocouple, -40 ░C to 0 ░C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in K: 0.25
Comparison with SPRT
Glycol bath
Approved on 03 November 2009
Internal NMI service identifier: FSB-LPM/2.3.1