CMC AREA
CMCs Chemistry (618)
CMCs General Physics (377)
CMCs Ionizing Radiation (214)
PHYSICS >
Temperature (67)
Dimensional metrology (34)
Sound in air (33)
Radio frequency measurements (20)
Vibration (19)
Properties of detectors and sources (19)
DC voltage, current, and resistance (18)
AC voltage, current, and power (14)
Frequency (13)
Time interval (12)
Electric and magnetic fields (12)
Pressure (11)
IONIZING RADIATION >
Activity per unit mass (107)
Activity (43)
Surface emission rate (13)
Emission rate (9)
Surface emission rate per unit area (9)
Ambient dose equivalent rate (8)
Air kerma rate (4)
Personal dose equivalent rate (4)
Activity per unit volume (4)
Emission anisotropy (2)
CHEMICAL MATERIAL >
nitrogen (207)
methane (45)
monoelemental aqueous solution (35)
dairy products (24)
helium (20)
CHEMICAL ANALYTE >
carbon monoxide (24)
carbon dioxide (21)
oxygen (20)
lead (14)
nitrogen (14)
GEOGRAPHIC LOCATION
APMP (1209)
Korea, Republic of (1209)
Result of the search
Your query 'kriss' produced more than 1000 results New search
1  2  3 [Next >>]

 
Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Acoustics, Ultrasound, Vibration for Korea, Republic of (.PDF file)
Pressure sensitivity level (modulus). Measurement microphone type LS1P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.05
IEC 61094-2:1992 (reciprocity)
Frequency: 20 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111
 
Pressure sensitivity level (modulus). Measurement microphone type LS1P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.04
IEC 61094-2:1992 (reciprocity)
Frequency: 25 Hz to 3.15 kHz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111
 
Pressure sensitivity level (modulus). Measurement microphone type LS1P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.05
IEC 61094-2:1992 (reciprocity)
Frequency: 4 kHz to 8 kHz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111
 
Pressure sensitivity level (modulus). Measurement microphone type LS1P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.06
IEC 61094-2:1992 (reciprocity)
Frequency: 10 kHz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111
 
Pressure sensitivity level (modulus). Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.08
IEC 61094-2:1992 (reciprocity)
Frequency: 31.5 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111
 
Pressure sensitivity level (modulus). Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.06
IEC 61094-2:1992 (reciprocity)
Frequency: 40 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111
 
Pressure sensitivity level (modulus). Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.05
IEC 61094-2:1992 (reciprocity)
Frequency: 50 Hz to 125 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111
 
Pressure sensitivity level (modulus). Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.04
IEC 61094-2:1992 (reciprocity)
Frequency: 160 Hz to 8 kHz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111
 
Pressure sensitivity level (modulus). Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.05
IEC 61094-2:1992 (reciprocity)
Frequency: 10 kHz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111
 
Pressure sensitivity level (modulus). Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.06
IEC 61094-2:1992 (reciprocity)
Frequency: 12.5 kHz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111
 
Pressure sensitivity level (modulus). Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.07
IEC 61094-2:1992 (reciprocity)
Frequency: 16 kHz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111
 
Pressure sensitivity level (modulus). Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.10
IEC 61094-2:1992 (reciprocity)
Frequency: 20 kHz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111
 
Pressure sensitivity level (modulus). Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.20
IEC 61094-2:1992 (reciprocity)
Frequency: 25 kHz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111
 
Pressure sensitivity level (modulus). Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 1.0
IEC 61094-2:1992 (reciprocity)
Frequency: 31.5 kHz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111
 
Pressure sensitivity level (modulus). Measurement microphone type WS2P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.14
IEC 61094-5:2001 (simultaneous comparison)
Frequency: 20 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111
 
Pressure sensitivity level (modulus). Measurement microphone type WS2P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.12
IEC 61094-5:2001 (simultaneous comparison)
Frequency: 25 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111
 
Pressure sensitivity level (modulus). Measurement microphone type WS2P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.11
IEC 61094-5:2001 (simultaneous comparison)
Frequency: 31.5 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111
 
Pressure sensitivity level (modulus). Measurement microphone type WS2P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.10
IEC 61094-5:2001 (simultaneous comparison)
Frequency: 40 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111
 
Pressure sensitivity level (modulus). Measurement microphone type WS2P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.09
IEC 61094-5:2001 (simultaneous comparison)
Frequency: 50 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111
 
Pressure sensitivity level (modulus). Measurement microphone type WS2P. Measurand unit, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.08
IEC 61094-5:2001 (simultaneous comparison)
Frequency: 63 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C61111