Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (62)
CMCs Chemistry (7)
PHYSICS
Frequency (16)
Torque, Viscosity, Hardness and Gravity (11)
Temperature (9)
Mass, mass standards (6)
Time interval (5)
Time scale difference (4)
Laser frequencies (3)
Dimensional metrology (3)
DC voltage, current, and resistance (2)
Impedance up to the MHz range (2)
Radio frequency measurements (1)
CHEMICAL MATERIAL
nitrogen (5)
aqueous buffer solution (1)
nitrogen or air (1)
CHEMICAL ANALYTE
carbon monoxide (2)
propane (2)
carbon dioxide (1)
oxygen (1)
GEOGRAPHIC LOCATION
COOMET (69)
Kazakhstan (69)
Result of the search
Your query 'kazinmetr' produced 69 results New search
1  2  3 [Next >>]

 
Kazakhstan, KazInMetr (Kazakh Institute of Metrology RSE)
Complete CMCs in Time and Frequency for Kazakhstan (.PDF file)
Time scale difference. Local clock vs UTC, -1 s to 1 s
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in ns: 5.1
Time interval measurement
Pulse amplitude: > 1 V
Slew rate: > 0.5 V/ns
Fractional part of modulo 1 second difference, integer part can be provided also
Approved on 13 March 2015
 
Time scale difference. Local clock vs UTC, -1 s to 1 s
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in ns: 151
Comparison against UTC
Pulse amplitude: > 1 V
Slew rate: > 0.5 V/ns
Prediction time: 10 days
Predicted
Fractional part of modulo 1 second difference, integer part can be provided also
Approved on 13 March 2015
 
Time scale difference. Remote clock vs UTC, -1 s to 1 s
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in ns: 97
GPS common view comparison against UTC(KZ)
Pulse amplitude: > 1 V
Slew rate: > 0.5 V/ns
Averaging time: 5 days
Distance: < 1500 km
Fractional part of modulo 1 second difference, integer part can be provided also
Approved on 13 March 2015
 
Time scale difference. Remote clock vs UTC, -1 s to 1 s
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in ns: 172
GPS common view comparison against UTC
Pulse amplitude: > 1 V
Slew rate: > 0.5 V/ns
Prediction time: 10 days
Distance: < 1500 km
Predicted
Fractional part of modulo 1 second difference, integer part can be provided also
Approved on 13 March 2015
 
Time interval. Period source, 1E-06 s to 1E+03 s
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in ns: 10
Time interval counter
Gate time: > 1 s
Slew rate: 0.5 V/ns
Approved on 13 March 2015
 
Time interval. Time difference source, 1E-09 s to 1E-06 s
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in ns: 2
Time interval measurement
Number of measurements: 100
Amplitude: 1 V to 4 V
Slew rate: 0.5 V/ns
Approved on 13 March 2015
 
Time interval. Time difference source, 1E-06 s to 1E+03 s
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in ns: 2
Time interval measurement
Number of measurements: 10
Amplitude: 1 V to 4 V
Slew rate: 0.5 V/ns
Approved on 13 March 2015
 
Time interval. Time difference meter, 1E-09 s to 1E-06 s
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in ns: 2
Time interval measurement
Number of measurements: 100
Amplitude: 1 V to 4 V
Slew rate: 0.5 V/ns
Approved on 13 March 2015
 
Time interval. Time difference meter, 1E-06 s to 1E+03 s
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in ns: 2
Time interval measurement
Number of measurements: 10
Amplitude: 1 V to 4 V
Slew rate: 0.5 V/ns
Approved on 13 March 2015
 
Frequency. Local frequency standard, 5 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 1E-12
Frequency comparator
Averaging time: 1 s
Amplitude: 0.8 V to 1.2 V
Approved on 24 October 2011
Internal NMI service identifier: RP UKF "KazInMetr" 06
 
Frequency. Local frequency standard, 10 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 1E-12
Frequency comparator
Averaging time: 1 s
Amplitude: 0.8 V to 1.2 V
Approved on 24 October 2011
Internal NMI service identifier: RP UKF "KazInMetr" 07
 
Frequency. Local frequency standard, 5 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 2.7E-13
Frequency comparator
Averaging time: 1E+03 s
Amplitude: 0.8 V to 1.2 V
Approved on 24 October 2011
Internal NMI service identifier: RP UKF "KazInMetr" 08
 
Frequency. Local frequency standard, 10 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 2.7E-13
Frequency comparator
Averaging time: 1E+03 s
Amplitude: 0.8 V to 1.2 V
Approved on 24 October 2011
Internal NMI service identifier: RP UKF "KazInMetr" 09
 
Frequency. Local frequency standard, 0.1 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 2.4E-13
Phase measurement
Averaging time: 1 day
Amplitude: 0.5 V to 2.4 V
Approved on 13 March 2015
 
Frequency. Local frequency standard, 5 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 2.4E-13
Phase measurement
Averaging time: 1 day
Amplitude: 0.5 V to 2.4 V
Approved on 13 March 2015
 
Frequency. Local frequency standard, 10 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 2.4E-13
Phase measurement
Averaging time: 1 day
Amplitude: 0.8 V to 2.4 V
Approved on 13 March 2015
 
Frequency. Remote frequency standard, 5 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 1E-12
GPS common view comparison against UTC
Averaging time: 5 days
Baseline length from KazInMetr: < 1500 km
Post processed
Approved on 13 March 2015
 
Frequency. Remote frequency standard, 10 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 1E-12
GPS common view comparison against UTC
Averaging time: 5 days
Baseline length from KazInMetr: < 1500 km
Post processed
Approved on 13 March 2015
 
Frequency. General frequency source, 0.1 Hz to 1E+03 Hz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 3E-07
Direct frequency measurement
Averaging time: 1000 s
Amplitude: > 0.5 Vrms
Approved on 13 March 2015
 
Frequency. General frequency source, 1 kHz to 1E+06 kHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 3E-09
Direct frequency measurement
Averaging time: 1000 s
Amplitude: > 0.5 Vrms
Approved on 13 March 2015