Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (227)
CMCs Chemistry (33)
CMCs Ionizing Radiation (15)
PHYSICS >
Temperature (63)
Sound in air (30)
Dimensional metrology (25)
Frequency (20)
Radio frequency measurements (15)
Impedance up to the MHz range (14)
AC voltage, current, and power (13)
High voltage and current (9)
Time scale difference (7)
Photometry (6)
Mass, mass standards (5)
Torque, Viscosity, Hardness and Gravity (4)
IONIZING RADIATION
Activity per unit mass (14)
Activity per unit volume (1)
CHEMICAL MATERIAL >
synthetic natural gas (7)
aqueous pH buffer solution (6)
nitrogen (6)
aqueous solution (3)
high purity propane (3)
CHEMICAL ANALYTE >
propane (4)
nitrogen (3)
carbon monoxide (3)
sulfur dioxide (2)
ethanol (2)
GEOGRAPHIC LOCATION
COOMET (275)
Ukraine (275)
Result of the search
Your query 'Ukraine' produced 275 results New search
1  2  3 [Next >>]

 
Ukraine, NSC "Institute of Metrology" (National Scientific Centre "Institute of Metrology")
Complete CMCs in Electricity and Magnetism for Ukraine (.PDF file)
Signal and pulse characteristics: modulation, AM. Signal generator, modulation meter, 0.1 % to 100 %
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in %: (0.002M + 0.05), M AM coefficient
Comparison with comparator, direct measurement
Carrier frequency: 0.01 MHz to 500 MHz
Modulation frequency: 0.02 kHz to 200 kHz
Approved on 28 April 2010
Internal NMI service identifier: NSC "Institute of Metrology"/12
 
Signal and pulse characteristics: modulation, FM. Signal generator, modulation meter, 1E+02 Hz to 1E+06 Hz
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Hz: (0.0025df + 10), df frequency deviation
Comparison with comparator
Carrier frequency: 0.1 MHz to 10 GHz
Modulation frequency: 0.02 kHz to 200 kHz
Approved on 28 April 2010
Internal NMI service identifier: NSC "Institute of Metrology"/14
 
Signal and pulse characteristics: distortion and harmonic content. Reference standard, signal generator, distortion meter, 3E-03 % to 1E+02 %
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in %: (0.01 KH), KH coefficient of harmonic content
Direct comparison, direct measurement
Frequency: 0.01 kHz to 200 kHz
Approved on 28 April 2010
Internal NMI service identifier: NSC "Institute of Metrology"/15
 
Ukraine, SE "Ukrmetrteststandard" (State Enterprise "Ukrmetrteststandard")
Complete CMCs in Electricity and Magnetism for Ukraine (.PDF file)
Capacitance: dissipation factor for low loss capacitors. Standard capacitor, 1E-05 to 0.01
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 8E-05
Transformer bridge
Capacitance: 10 pF, 100 pF
Frequency: 1 kHz
Approved on 28 July 2010
Internal NMI service identifier: SE "Ukrmetrteststandard"/19
 
Capacitance: meters. Capacitance bridge, LCR meter, 1 pF to 1000 pF
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µF/F: 12
Comparison to capacitance standard
Frequency: 1 kHz, 1.592 kHz
Approved on 28 July 2010
Internal NMI service identifier: SE "Ukrmetrteststandard"/20
 
Capacitance: meters. Capacitance bridge, LCR meter, 1 nF to 10 nF
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µF/F: 14
Comparison to capacitance standard
Frequency: 1 kHz, 1.592 kHz
Approved on 28 July 2010
Internal NMI service identifier: SE "Ukrmetrteststandard"/21
 
Inductance: quality factor. Q standard, 100 to 1000
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 100
Transformer bridge
Frequency: 1 kHz
Inductance: 0.001 mH to 10 mH
Approved on 28 July 2010
Internal NMI service identifier: SE "Ukrmetrteststandard"/26
 
Phase angle: sources. Phase generator, 0 ° to 360 °
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in °: 0.014 to 0.018
Comparison
Frequency range: 42 Hz to 1 kHz
Voltage: 50 mV to 120 V
Approved on 09 March 2015
Internal NMI service identifier: SE "Ukrmetrteststandard"/36
Uncertainty table
 
Phase angle: meters. Phase meter, 0 ° to 360 °
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in °: 0.012 to 0.015
Comparison
Frequency range: 42 Hz to 1 kHz
Voltage: 50 mV to 120 V
Approved on 09 March 2015
Internal NMI service identifier: SE "Ukrmetrteststandard"/38
Uncertainty table
 
High AC current: ratio phase displacement. Current transformer, 3E-05 rad to 0.058 rad
Relative expanded uncertainty (k = 2, level of confidence 95 %) in rad: 1E-04 to 1E-03
Comparison by means of a comparator
Frequency: 50 Hz
Primary current: 0.5 A to 10000 A
Secondary current: 0.5 A, 1 A, 2 A, 2.5 A, 5 A
Approved on 15 December 2008
Internal NMI service identifier: SE "Ukrmetrteststandard"/14
 
Ukraine, NSC "Institute of Metrology" (National Scientific Centre "Institute of Metrology")
Complete CMCs in Electricity and Magnetism for Ukraine (.PDF file)
DC resistance standards and sources: low values. Fixed resistor, 1E-03 to 1E-01
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 2 to 3
Bridge by substitution and resistance ratio set
Temperature: 19.5 °C to 20.5 °C
Approved on 28 April 2010
Internal NMI service identifier: NSC "Institute of Metrology"/4
Uncertainty table
 
DC resistance standards and sources: intermediate values. Fixed resistor, 1 to 1E+06
Relative expanded uncertainty (k = 2, level of confidence 95 %) in n/: 200 to 1600
Bridge by substitution, Hamon transfer
Temperature: 19.5 °C to 20.5 °C
Approved on 28 April 2010
Internal NMI service identifier: NSC "Institute of Metrology"/5
Uncertainty table
 
DC resistance standards and sources: high values. Fixed resistor, 1E+07 to 1E+09
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 10 to 60
Bridge by substitution, Hamon transfer
Temperature: 19.5 °C to 20.5 °C
Approved on 28 April 2010
Internal NMI service identifier: NSC "Institute of Metrology"/6
Uncertainty table
 
Magnetic fields below 50 kHz: DC magnetic flux density. Magnetic inductance meter, 0.05 T to 2 T
Relative expanded uncertainty (k = 2, level of confidence 95 %) in T/T: 4E-06
Nuclear magnetic resonance
Approved on 28 April 2010
Internal NMI service identifier: NSC "Institute of Metrology"/7
 
Radio frequency power: absolute power on coaxials. Power meter, power source, 1E-03 W to 1E-02 W
Relative expanded uncertainty (k = 2, level of confidence 95 %) in W/W: 1.1E-02
Direct comparison, comparison with comparator
Frequency: 0.03 GHz to 18.0 GHz
Connector type: III GOST R13317
Approved on 28 April 2010
Internal NMI service identifier: NSC "Institute of Metrology"/8
 
Radio frequency power: calibration factor and effective efficiency on coaxials. Thermistor, barretter, 8E-01 to 1
Relative expanded uncertainty (k = 2, level of confidence 95 %) in W/W: 1.1E-02
Direct comparison, comparison with comparator
Frequency: 0.03 GHz to 18.0 GHz
Connector type: III GOST R13317
Approved on 28 April 2010
Internal NMI service identifier: NSC "Institute of Metrology"/9
 
Radio frequency power: absolute power in waveguide. Power meter, power source, 1E-03 W to 1E-02 W
Relative expanded uncertainty (k = 2, level of confidence 95 %) in W/W: 1.1E-02 to 1.5E-02
Direct comparison, comparison with comparator
Frequency: 37.5 GHz to 178.6 GHz
Approved on 28 April 2010
Internal NMI service identifier: NSC "Institute of Metrology"/10
Uncertainty table
 
Radio frequency power: calibration factor and effective efficiency in waveguide. Thermistor, barretter, 6E-01 to 1
Relative expanded uncertainty (k = 2, level of confidence 95 %) in W/W: 1.1E-02 to 1.5E-02
Direct comparison, comparison with comparator
Frequency: 37.5 GHz to 178.6 GHz
Approved on 28 April 2010
Internal NMI service identifier: NSC "Institute of Metrology"/11
Uncertainty table
 
RF voltage and current: RF-DC difference. Thermal voltage converter, 0.1 V to 3 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in mV/V: 1 to 5
Comparison with reference
Frequency: 30 MHz to 100 MHz
Approved on 28 April 2010
Internal NMI service identifier: NSC "Institute of Metrology"/18
 
RF voltage and current: RF-DC difference. Thermal voltage converter, 0.1 V to 3 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in mV/V: 2 to 10
Comparison with reference
Frequency: 100 MHz to 300 MHz
Approved on 28 April 2010
Internal NMI service identifier: NSC "Institute of Metrology"/19