Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (15)
CMCs Chemistry (2)
PHYSICS
Vibration (12)
Sound in air (3)
CHEMICAL MATERIAL
aqueous media (1)
brown rice (1)
CHEMICAL ANALYTE
cadmium (1)
ethanol (1)
GEOGRAPHIC LOCATION
AFRIMETS (17)
Kenya (17)
Result of the search
Your query 'Kenya' produced 17 results New search

 
Kenya, KEBS (Kenya Bureau of Standards)
Complete CMCs in Acoustics, Ultrasound, Vibration for Kenya (.PDF file)
Pressure sensitivity level. Measurement microphone type LS2P, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in dB: 0.07
IEC 61094-2:2009
Frequency: 10 Hz to 31.5 Hz
Approved on 30 June 2016
Internal NMI service identifier: KEBS/A2.1
 
Pressure sensitivity level. Measurement microphone type LS2P, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in dB: 0.04
IEC 61094-2:2009
Frequency: 40 Hz to 8 kHz
Approved on 30 June 2016
Internal NMI service identifier: KEBS/A2.1
 
Pressure sensitivity level. Measurement microphone type LS2P, dB (reference: 1 V/Pa)
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in dB: 0.07
IEC 61094-2:2009
Frequency:  10 kHz to 16 kHz
Approved on 30 June 2016
Internal NMI service identifier: KEBS/A2.1
 
Frequency response (modulus). Acceleration measuring instrument, 0.1 m/s2 to 200 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.0
ISO 16063-21:2003 (comparison)
Frequency: 10 Hz to 1 kHz
Approved on 30 June 2016
Internal NMI service identifier: KEBS/A2.6
 
Frequency response (modulus). Acceleration measuring instrument, 0.1 m/s2 to 200 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.5
ISO 16063-21:2003 (comparison)
Frequency: >1 kHz to 5 kHz
Approved on 30 June 2016
Internal NMI service identifier: KEBS/A2.6
 
Frequency response (modulus). Acceleration measuring instrument, 0.1 m/s2 to 200 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 2.0
ISO 16063-21:2003 (comparison)
Frequency: > 5 kHz to 7.5 kHz
Approved on 25 September 2018
Internal NMI service identifier: KEBS/A2.6
 
Frequency response (modulus). Acceleration measuring instrument, 0.1 m/s2 to 200 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 2.2
ISO 16063-21:2003 (comparison)
Frequency: > 7.5 kHz to 10 kHz
Approved on 25 September 2018
Internal NMI service identifier: KEBS/A2.6
 
Charge sensitivity (modulus). Accelerometer, C/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.0
ISO 16063-21:2003 (comparison)
Frequency: 10 Hz to 1 kHz
Approved on 30 June 2016
Internal NMI service identifier: KEBS/A2.6
 
Charge sensitivity (modulus). Accelerometer, C/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.5
ISO 16063-21:2003 (comparison)
Frequency: >1 kHz to 5 kHz
Approved on 30 June 2016
Internal NMI service identifier: KEBS/A2.6
 
Charge sensitivity (modulus). Acceleration measuring chain/accelerometer, C/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 2.0
ISO 16063-21:2003 (comparison)
Frequency: > 5 kHz to 7.5 kHz
Approved on 25 September 2018
Internal NMI service identifier: KEBS/A2.6
 
Charge sensitivity (modulus). Acceleration measuring chain/accelerometer, C/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 2.2
ISO 16063-21:2003 (comparison)
Frequency: > 7.5 kHz to 10 kHz
Approved on 25 September 2018
Internal NMI service identifier: KEBS/A2.6
 
Voltage sensitivity (modulus). Acceleration measuring chain, V/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.0
ISO 16063-21:2003 (comparison)
Frequency: 10 Hz to 1 kHz
Approved on 30 June 2016
Internal NMI service identifier: KEBS/A2.6
 
Voltage sensitivity (modulus). Acceleration measuring chain, V/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.5
ISO 16063-21:2003 (comparison)
Frequency: >1 kHz to 5 kHz
Approved on 30 June 2016
Internal NMI service identifier: KEBS/A2.6
 
Voltage sensitivity (modulus). Acceleration measuring chain/accelerometer, V/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 2.0
ISO 16063-21:2003 (comparison)
Frequency: > 5 kHz to 7.5 kHz
Approved on 25 September 2018
Internal NMI service identifier: KEBS/A2.6
 
Voltage sensitivity (modulus). Acceleration measuring chain/accelerometer, V/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 2.2
ISO 16063-21:2003 (comparison)
Frequency: > 7.5 kHz to 10 kHz
Approved on 25 September 2018
Internal NMI service identifier: KEBS/A2.6
Kenya, KEBS (Kenya Bureau of Standards)
Complete CMCs in Chemistry for Food for Kenya (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in mg/g Relative expanded uncertainty
(k = 2, 95%) in %
aqueous media ethanol 0.20 to 25.0 1.9 to 7.2
Mechanism(s) for measurement service delivery: Reference measurement
Uncertainty convention 1.
Approved on 13 June 2013.
Internal NMI service identifier: KEBS/IPS-Q11-04-2

Kenya, KEBS (Kenya Bureau of Standards)
Complete CMCs in Chemistry for Food for Kenya (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in mg/kg Absolute expanded uncertainty
(k = 2, 95%) in mg/kg
brown rice cadmium 0.2 to 0.5 0.07 to 0.12
Mechanism(s) for measurement service delivery: Provision of reference value for client samples
Uncertainty convention 1.
Microwave Plasma Atomic Emission Spectrometry used to determine cadmium mass fraction in rice after microwave digestion of the sample.
Approved on 28 June 2016.
Internal NMI service identifier: KEBS/TES/ING/TM/52-CCQM