Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (62)
CMCs Chemistry (6)
PHYSICS
Frequency (16)
Torque, Viscosity, Hardness and Gravity (11)
Temperature (9)
Mass, mass standards (6)
Time interval (5)
Time scale difference (4)
Dimensional metrology (3)
Laser frequencies (3)
DC voltage, current, and resistance (2)
Impedance up to the MHz range (2)
Radio frequency measurements (1)
CHEMICAL MATERIAL
nitrogen (4)
aqueous buffer solution (1)
nitrogen or air (1)
CHEMICAL ANALYTE
carbon monoxide (2)
carbon dioxide (1)
oxygen (1)
propane (1)
GEOGRAPHIC LOCATION
COOMET (68)
Kazakhstan (68)
Result of the search
Your query 'Kazakhstan' produced 68 results New search
1  2  3 [Next >>]

 
Kazakhstan, KazInMetr (Kazakh Institute of Metrology RSE)
Complete CMCs in Mass and related quantities for Kazakhstan (.PDF file)
Hardness. Hardness block, According to ISO 6508:1 and GOST 9013 HRA
Absolute expanded uncertainty (k = 2, level of confidence 95%) in HRA: 0.5
Rockwell A according ISO 6508:3 and GOST 9013
Preliminary test force: 98.07 N
Total test force: 588.4 N
Approved on 16 April 2010
 
Hardness. Hardness block, According to ISO 6501:3 and GOST 9013 HRB
Absolute expanded uncertainty (k = 2, level of confidence 95%) in HRB: 0.8
Rockwell B according ISO 6508:3 and GOST 9013
Preliminary test force: 98.07 N
Total test force: 980.7 N
Approved on 16 April 2010
 
Hardness. Hardness block, According to ISO 6508:1 and GOST 9013 HRC
Absolute expanded uncertainty (k = 2, level of confidence 95%) in HRC: 0.5
Rockwell C according ISO 6508:3 and GOST 9013
Preliminary test force: 98.07 N
Total test force: 1471 N
Approved on 16 April 2010
 
Hardness. Hardness block, According to ISO 6508:1 and GOST 22975 HRN
Absolute expanded uncertainty (k = 2, level of confidence 95%) in HRN: 0.7
Rockwell N according ISO 6508:3 and GOST 22975
Preliminary test force: 29.42 N
Total test force: 147.1 N to 441.3 N
Approved on 16 April 2010
 
Hardness. Hardness block, According to ISO 6508:3 and GOST 22975 HRT
Absolute expanded uncertainty (k = 2, level of confidence 95%) in HRT: 0.8
Rockwell 15T according ISO 6508:3 and GOST 22975
Preliminary test force: 29.42 N
Total test force: 147.1 N
Approved on 16 April 2010
 
Hardness. Hardness block, According to ISO 6508:3 and GOST 22975 HRT
Absolute expanded uncertainty (k = 2, level of confidence 95%) in HRT: 1.2
Rockwell 30T according ISO 6508:3 and GOST 22975
Preliminary test force: 29.42 N
Total test force: 294.2 N
Approved on 16 April 2010
 
Mass. Mass standards, 1 mg to 100 mg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µg: 1.5 to 2.4
Subdivision method
Temperature: 17.5 °C to 22.5 °C
Relative humidity: 40 % to 60 %
Uncertainty scales with measurand level. The volume of the mass standards is known
Approved on 10 September 2014
 
Mass. Mass standards, 0.1 g to 1 g
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µg: 2.4 to 3
Subdivision method
Temperature: 17.5 °C to 22.5 °C
Relative humidity: 40 % to 60 %
Uncertainty scales with measurand level. The volume of the mass standards is known
Approved on 10 September 2014
 
Mass. Mass standards, 1 g to 10 g
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µg: 3 to 6
Subdivision method
Temperature: 17.5 °C to 22.5 °C
Relative humidity: 40 % to 60 %
Uncertainty scales with measurand level. The volume of the mass standards is known
Approved on 10 September 2014
 
Mass. Mass standards, 10 g to 100 g
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µg: 6 to 16
Subdivision method
Temperature: 17.5 °C to 22.5 °C
Relative humidity: 40 % to 60 %
Uncertainty scales with measurand level. The volume of the mass standards is known
Approved on 10 September 2014
 
Mass. Mass standards, 0.1 kg to 1 kg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µg: 16 to 120
Subdivision method
Temperature: 17.5 °C to 22.5 °C
Relative humidity: 40 % to 60 %
Uncertainty scales with measurand level. The volume of the mass standards is known
Approved on 10 September 2014
 
Mass. Mass standards, 1 kg to 10 kg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.12 to 1.6
Direct comparison
Temperature: 17.5 °C to 22.5 °C
Relative humidity: 40 % to 60 %
Uncertainty scales with measurand level. The volume of the mass standards is known
Approved on 10 September 2014
 
Hardness. Hardness block, According to ISO 6507:1 HV
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1.7
Vickers HV1 according to ISO 6507:3
Test force: 9.807 N
Approved on 28 February 2014
 
Hardness. Hardness block, According to ISO 6507:1 HV
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1.5
Vickers HV5, HV30 according to ISO 6507:3
Test force: 49.03 N, 294.2 N
Approved on 28 February 2014
 
Viscosity. Newtonian liquids, 20 mm2/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.25
Reference liquids
Temperature:  20 °C
 
Viscosity. Newtonian liquids, 100 mm2/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.32
Reference liquids
Temperature:  20 °C
 
Viscosity. Newtonian liquids, 1000 mm2/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.4
Reference liquids
Temperature:  20 °C
 
Time scale difference. Local clock vs. UTC(KZ), -1 s to 1 s
Absolute expanded uncertainty (k = 2, level of confidence 95%) in ns: 5.1
Time interval measurement
Pulse amplitude: > 1 V
Slew rate: > 0.5 V/ns
Fractional part of modulo 1 second difference, integer part can be provided also
Approved on 13 March 2015
 
Time scale difference. Local clock vs. UTC, -1 s to 1 s
Absolute expanded uncertainty (k = 2, level of confidence 95%) in ns: 151
Comparison against UTC
Pulse amplitude: > 1 V
Slew rate: > 0.5 V/ns
Prediction time: 10 days
Predicted
Fractional part of modulo 1 second difference, integer part can be provided also
Approved on 13 March 2015
 
Time scale difference. Remote clock vs. UTC(KZ), -1 s to 1 s
Absolute expanded uncertainty (k = 2, level of confidence 95%) in ns: 97
GPS common view comparison against UTC(KZ)
Pulse amplitude: > 1 V
Slew rate: > 0.5 V/ns
Averaging time: 5 days
Distance: < 1500 km
Fractional part of modulo 1 second difference, integer part can be provided also
Approved on 13 March 2015