Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (123)
CMCs Ionizing Radiation (35)
CMCs Chemistry (19)
PHYSICS
Temperature (48)
DC voltage, current, and resistance (21)
Fluid flow (15)
AC voltage, current, and power (13)
Mass, mass standards (9)
Humidity (6)
Radio frequency measurements (4)
Impedance up to the MHz range (3)
Laser frequencies (2)
Dimensional metrology (2)
IONIZING RADIATION >
Air kerma rate (7)
Ambient dose equivalent rate (5)
Air kerma (5)
Personal dose equivalent penetrating (at 10 mm depth) (5)
Personal dose equivalent superficial (at 0.07 mm depth) (5)
Air kerma area product (2)
Reference air kerma rate (2)
X-ray tube voltage (2)
Absorbed dose to water (1)
Air kerma length product (1)
CHEMICAL MATERIAL >
water (6)
blood serum (2)
tissue of animal origin (2)
plant origin food (2)
avermectin (1)
CHEMICAL ANALYTE >
cadmium (2)
lead (2)
zinc (1)
copper (1)
iron (1)
GEOGRAPHIC LOCATION
EURAMET (177)
Greece (177)
Result of the search
Your query 'Greece' produced 177 results New search
1  2  3 [Next >>]

 
Greece, EIM (Hellenic Institute of Metrology)
Complete CMCs in Mass and related quantities for Greece (.PDF file)
Mass. Mass standard, 1 mg to 100 mg
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in µg: 0.6 to 1.5
Comparison in air
Uncertainty scales with measurand level
The volume of the mass standards is known
Approved on 18 November 2010
 
Mass. Mass standard, 0.1 g to 1 g
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in µg: 1.5 to 3
Comparison in air
Uncertainty scales with measurand level
The volume of the mass standards is known
Approved on 18 November 2010
 
Mass. Mass standard, 1 g to 10 g
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in µg: 3 to 5
Comparison in air
Uncertainty scales with measurand level
The volume of the mass standards is known
Approved on 18 November 2010
 
Mass. Mass standard, 10 g to 100 g
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in µg: 5 to 12
Comparison in air
Uncertainty scales with measurand level
The volume of the mass standards is known
Approved on 18 November 2010
 
Mass. Mass standard, 0.1 kg to 1 kg
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in µg: 12 to 90
Comparison in air
Uncertainty scales with measurand level
The volume of the mass standards is known
Approved on 18 November 2010
 
Mass. Mass standard, 1 kg to 10 kg
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in mg: 0.09 to 1.3
Comparison in air
Uncertainty scales with measurand level
The volume of the mass standards is known
Approved on 18 November 2010
 
Mass. Mass standard, 20 kg to 50 kg
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in mg: 5.2 to 12
Comparison in air
Uncertainty scales with measurand level
The volume of the mass standards is known
Approved on 18 November 2010
 
Mass. Mass standard, 60 kg to 100 kg
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in mg: 320 to 550
Comparison in air
Uncertainty scales with measurand level
The volume of the mass standards is known
Approved on 18 November 2010
 
Mass. Mass standard, 100 kg to 500 kg
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in g: 0.55 to 2.7
Comparison in air
Uncertainty scales with measurand level
The volume of the mass standards is known
Approved on 18 November 2010
 
Volume water flowrate. Flow meter, 6 L/h to 30000 L/h
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.1
Gravimetric
Temperature: ambient to 70 °C
Pipe diameter: DN 10 to DN 50
Approved on 10 November 2011
Internal NMI service identifier: EIM/CAL-FLO-201
 
Volume gas flowrate. Flow meter, 9 L/h to 72 L/h
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.2
Volumetric
Pipe diameter: DN 10
Approved on 10 November 2011
Internal NMI service identifier: EIM/CAL-FLO-100
 
Volume gas flowrate. Flow meter, 72 L/h to 430 L/h
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.15
Volumetric
Pipe diameter: DN 10
Approved on 10 November 2011
Internal NMI service identifier: EIM/CAL-FLO-100
 
Volume gas flowrate. Flow meter, 1000 L/h to 60000 L/h
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.2
Volumetric
Pipe diameter: DN 10 to DN 40
Approved on 10 November 2011
Internal NMI service identifier: EIM/CAL-FLO-100
 
Mass water flowrate. Flow meter, 6 kg/h to 30000 kg/h
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.1
Gravimetric
Temperature: ambient to 70 °C
Pipe diameter: DN 10 to DN 50
Approved on 10 November 2011
Internal NMI service identifier: EIM/CAL-FLO-201
 
Volume of liquid. Micropipettes or piston pipettes, 20 µL to 1000 µL
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.2 to 0.05
Gravimetric
Liquid: water
Reference temperature: 20 °C
Approved on 10 November 2011
Internal NMI service identifier: EIM/CAL-VOL-101
 
Volume of liquid. Pipettes, burettes, 5 mL to 50 mL
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.02
Gravimetric
Liquid: water
Reference temperature: 20 °C
Approved on 10 November 2011
Internal NMI service identifier: EIM/CAL-VOL-101
 
Volume of liquid. Volumetric flasks, 10 mL to 5000 mL
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.1 to 0.015
Gravimetric
Liquid: water
Reference temperature: 20 °C
Approved on 10 November 2011
Internal NMI service identifier: EIM/CAL-VOL-101
 
Volume of liquid. Proving tanks, 1 L to 20 L
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.08 to 0.002
Gravimetric
Liquid: water
Reference temperature: 20 °C
Approved on 10 November 2011
Internal NMI service identifier: EIM/CAL-VOL-201
 
Volume of liquid. Proving tanks, 1 L to 20 L
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.01
Volumetric
Liquid: water
Reference temperature: 20 °C
Approved on 10 November 2011
Internal NMI service identifier: EIM/CAL-VOL-301
 
Volume of liquid. Proving tanks, 20 L to 400 L
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.003 to 0.02
Gravimetric
Liquid: water
Reference temperature: 20 °C or 15 °C
Approved on 10 November 2011
Internal NMI service identifier: EIM/CAL-VOL-202, EIM/CAL-VOL-203