Bosnia and Herzegovina, IMBIH (Institute of Metrology of Bosnia and Herzegovina)
Complete CMCs in Electricity and Magnetism for Bosnia and Herzegovina (.PDF file)
DC current meters: intermediate values. DC current meter, multimeter, 0.0001 A to 10 A
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µA/A: 27 to 625
Direct comparison with multifunction calibrator
Approved on 11 May 2017
Uncertainty table
 
DC current meters: intermediate values. DC current meter, multimeter, 0.0001 A to 10 A
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µA/A: 11 to 620
Direct comparison with reference digital multimeter
Approved on 11 May 2017
Uncertainty table
 
AC voltage up to 1100 V: sources. Multifunction calibrator, 0.01 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in mV/V: 0.08 to 31
Direct comparison with reference multimeter
Frequency: 50 Hz to 1 MHz
Approved on 11 May 2017
Uncertainty table
 
AC voltage up to 1100 V: meters. AC voltmeter, multimeter, 0.01 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in mV/V: 0.08 to 31
Direct comparison with reference multimeter
Frequency: 50 Hz to 1 MHz
Approved on 11 May 2017
Uncertainty table
 
AC voltage up to 1100 V: meters. AC voltmeter, multimeter, 0.01 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in mV/V: 0.15 to 31
Direct comparison with multifunction calibrator
Frequency: 50 Hz to 1 MHz
Approved on 11 May 2017
Uncertainty table
 
AC current up to 100 A: sources. AC current generator, multifunction calibrator, 0.0001 A to 10 A
Relative expanded uncertainty (k = 2, level of confidence 95 %) in mA/A: 0.36 to 3.5
Direct comparison with reference multimeter
Frequency: 50 Hz to 10 kHz
Approved on 11 May 2017
Uncertainty table
 
AC current up to 100 A: meters. AC ammeter, multimeter, 10 mA
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µA/A: 90
Drop voltage across the standard current shunt
Frequency: 300 Hz, 1 kHz
Approved on 11 May 2017
 
AC current up to 100 A: meters. AC ammeter, multimeter, 1.00E-04 A to 10 A
Relative expanded uncertainty (k = 2, level of confidence 95 %) in mA/A: 0.36 to 3.5
Direct comparison with a reference standard
Frequency: 50 Hz to 10 kHz
Approved on 11 May 2017
Internal NMI service identifier: IMBiH/15
Uncertainty table
 
DC voltage sources: single values. Solid state voltage standard, 10 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µV/V: 1
Direct comparison with a bank of solid state standards
Approved on 11 May 2017
Internal NMI service identifier: IMBiH/1
 
DC voltage sources: low values. DC voltage source, multifunction calibrator, 0.01 V to 10 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µV/V: 4 to 17
Comparison with reference digital multimeter
Approved on 11 May 2017
Internal NMI service identifier: IMBiH/2
Uncertainty table
 
DC voltage sources: intermediate values. DC voltage source, multifunction calibrator, 10 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µV/V: 4 to 8.5
Comparison with reference digital multimeter
Approved on 11 May 2017
Internal NMI service identifier: IMBiH/3
Uncertainty table
 
DC voltage meters: intermediate values. DC voltmeter, multimeter, 0.01 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µV/V: 4 to 17
Comparison with reference digital multimeter
Approved on 11 May 2017
Internal NMI service identifier: IMBiH/4
Uncertainty table
 
DC voltage meters: intermediate values. DC voltmeter, multimeter, 0.01 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µV/V: 5 to 45.5
Direct comparison with multifunction calibrator
Approved on 11 May 2017
Internal NMI service identifier: IMBiH/4
Uncertainty table
 
DC resistance standards and sources: intermediate values. Fixed resistor, 0.1 to 1
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 0.65
DC current comparator
Approved on 11 May 2017
Uncertainty table
 
DC resistance standards and sources: intermediate values. Fixed resistor, 1 to 1.00E+05
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 0.65
DC current comparator
Approved on 11 May 2017
Uncertainty table
 
DC resistance standards and sources: multiple ranges. Multifunction calibrator, 1 to 1.00E+08
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 8 to 135
Comparison with reference digital multimeter
Approved on 11 May 2017
Uncertainty table
 
DC resistance meters: intermediate values. Ohmeter, multimeter, 1 to 1.00E+09
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 1 to 19
Comparison to standard resistor
Approved on 11 May 2017
Uncertainty table
 
DC resistance meters: intermediate values. Ohmeter, multimeter, 1 M
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 5.2
Direct comparison with reference digital multimeter
Approved on 11 May 2017
 
DC current sources: low values. DC current generator, multifunction calibrator, 1 µA to 100 µA
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µA/A: 6.5 to 20
Drop voltage across the standard resistor
Approved on 11 May 2017
Uncertainty table
 
DC current sources: low values. DC current generator, multifunction calibrator, 10 µA to 100 µA
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µA/A: 13.5 to 50
Direct comparison with reference digital multimeter
Approved on 11 May 2017
Uncertainty table