Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (69)
CMCs Ionizing Radiation (2)
PHYSICS
DC voltage, current, and resistance
Temperature (29)
Dimensional metrology (19)
Pressure (10)
AC voltage, current, and power (4)
Laser frequencies (3)
Humidity (3)
Impedance up to the MHz range (1)
IONIZING RADIATION
Air kerma rate (1)
Absorbed dose rate to water (1)
GEOGRAPHIC LOCATION
EURAMET (71)
Croatia (71)
Result of the search
Your query 'Croatia' produced 71 results New search
1  2  3 [Next >>]

 
Croatia, FSB-LPM (FSB - Laboratory for Process Measurements)
Complete CMCs in Mass and related quantities for Croatia (.PDF file)
Absolute pressure. Absolute pressure gauge, 1.5E+03 Pa to 1.4E+05 Pa
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Pa: (6.1 + 4E-05p), p pressure in Pa
Gas medium
Uncertainty values range from 6.2 Pa to 12 Pa
Approved on 28 April 2008
 
Absolute pressure. Absolute pressure gauge, 1.4E+05 Pa to 1.4E+06 Pa
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Pa: (4 + 5E-05p), p pressure in Pa
Gas medium
Uncertainty values range from 11 Pa to 80 Pa
Approved on 28 April 2008
 
Gauge pressure. Pressure gauge, -1.0E+03 Pa to 3.0E+03 Pa
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Pa: (0.6 + 1.3E-04p), p pressure in Pa
Gas medium
Uncertainty values range from 0.6 Pa to 1 Pa
Approved on 28 April 2008
 
Gauge pressure. Pressure balance, 3.0E+03 Pa to 1.4E+05 Pa
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Pa: (1.8 + 7E-05p), p pressure in Pa
Gas medium
Uncertainty values range from 2 Pa to 12 Pa
Approved on 28 April 2008
 
Gauge pressure. Pressure balance, 1.4E+05 Pa to 1.4E+06 Pa
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Pa: (4 + 5E-05p), p pressure in Pa
Gas medium
Uncertainty values range from 11 Pa to 74 Pa
Approved on 28 April 2008
 
Gauge pressure. Pressure balance, 1.4E+06 Pa to 1.7E+07 Pa
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Pa: (7E-05p), p pressure in Pa
Gas medium
Uncertainty values range from 98 Pa to 1.2E+03 Pa
Approved on 28 April 2008
 
Gauge pressure. Pressure balance, 1.5E+05 Pa to 7.0E+06 Pa
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Pa: (25 + 5E-05p), p pressure in Pa
Oil medium
Uncertainty values range from 32 Pa to 3.5E+02 Pa
Approved on 28 April 2008
 
Gauge pressure. Pressure balance, 7.0E+06 Pa to 1.4E+08 Pa
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Pa: (280 + 1E-04p), p pressure in Pa
Oil medium
Uncertainty values range from 9.8E+02 Pa to 1.4E+04 Pa
Approved on 28 April 2008
 
Differential pressure. Pressure gauge, 0 Pa to 1.7E+07 Pa
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Pa: (1E-04p + 10), p pressure in Pa
Gas medium
Line pressure, pline, and differential pressure, p: line pressure from 1.0E+06 Pa to 1.79E+07 Pa
Uncertainty values range from 10 Pa to 1.7E+03 Pa
Approved on 28 April 2008
 
Differential pressure. Pressure gauge, 0 Pa to 1.0E+07 Pa
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Pa: (2E-04p + 50), p pressure in Pa
Oil medium
Line pressure, pline, and differential pressure, p: line pressure from 2.0E+06 Pa to 1.19E+07 Pa
Uncertainty values range from 50 Pa to 2E+03 Pa
Approved on 28 April 2008
 
Croatia, FSB-LPMD (FSB - Laboratory for Precise Measurements of Length)
Complete CMCs in Length for Croatia (.PDF file)
End standards. Gauge block: central length, L, 0.5 mm to 100 mm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Ám: (0.05 + 1.1L), L in m
Mechanical comparison, comparator
Approved on 30 January 2009
Internal NMI service identifier: FSB-LPMD/1
 
End standards. Long gauge block, 100 mm to 500 mm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Ám: (0.35 + 1.0L), L in m
Length measuring machine
Approved on 30 January 2009
Internal NMI service identifier: FSB-LPMD/2
 
End standards. Micrometer setting rod and length bar: central length L, 0 mm to 500 mm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Ám: (0.6 + 11.5L), L in m
Length measuring machine
Approved on 30 January 2009
Internal NMI service identifier: FSB-LPMD/3
 
Diameter standards. External cylinder (plug): diameter, 0.1 mm to 100 mm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Ám: 0.7
Length measuring machine
Approved on 03 November 2009
Internal NMI service identifier: FSB-LPMD/4
 
Diameter standards. External cylinder (plug): diameter, 100 mm to 200 mm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Ám: 1
Length measuring machine
Approved on 03 November 2009
Internal NMI service identifier: FSB-LPMD/4
 
Diameter standards. Internal cylinder (ring): diameter D, 8 mm to 150 mm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in Ám: (0.6 + 0.7D), D in m
Length measuring machine
Approved on 03 November 2009
Internal NMI service identifier: FSB-LPMD/5
 
Roughness standards. Roughness standards (ISO 5436-1 type C, D) ISO roughness parameter, 0.02 Ám to 30 Ám
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in nm: (12 + 38Ra), Ra in Ám
Roughness instrument
Average parameter, Ra: ISO 4287
Approved on 03 November 2009
Internal NMI service identifier: FSB-LPMD/8
 
Roughness standards. Roughness standards (ISO 5436-1 type C, D) ISO roughness parameter, 0.025 Ám to 100 Ám
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in nm: (22 + 46Rz), Rz in Ám
Roughness instrument
Peak parameter, Rz: ISO 4287
Approved on 03 November 2009
Internal NMI service identifier: FSB-LPMD/8
 
Laser radiations. Frequency stabilized laser: vacuum wavelength, 633 nm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in fm: 0.04
Optical beat frequency
Temperature: (20 ± 5) ░C
Approved on 01 April 2010
Internal NMI service identifier: FSB-LPMD/10
 
Laser radiations. Frequency stabilized laser: absolute frequency, 474 THz
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in kHz: 24
Optical beat frequency
Temperature: (20 ± 5) ░C
Approved on 01 April 2010
Internal NMI service identifier: FSB-LPMD/10