Ionizing Radiation
Mass (38)
Electricity and Magnetism (30)
Length (20)
Amount of Substance (18)
Acoustics, Ultrasound, and Vibration (11)
Thermometry (8)
Photometry and Radiometry (3)
Time and Frequency (1)
TYPE
Key comparisons (98)
Supplementary comparisons (31)
STATUS
Approved for equivalence (69)
Approved and published (16)
Approved for provisional equivalence (8)
Ongoing, approved for equivalence (7)
In progress (7)
Planned (6)
Protocol complete (6)
Published (4)
Report in progress, Draft A (4)
Measurements completed (1)
Abandoned (1)
ORGANISATIONS
APMP (75)
CCM (16)
CCQM (8)
BIPM (6)
CCEM (6)
EURAMET (formerly EUROMET) (6)
SIM (5)
CCAUV (5)
CCL (1)
CCTF (1)
Result of the search
Your query 'India' produced 129 results New search
1  2  3 [Next >>]

  APMP.QM- S7.1 Methane in Nitrogen
2018 - 2019
Comparison type, Field   Supplementary comparison in Amount of Substance, Gases
Status   Planned
  BIPM.EM- K13.a Comparison of resistance standards
1993 -
Comparison type, Field   Key comparison in Electricity and Magnetism, Resistance
Resistance: 1 ohm
Status   Ongoing, approved for equivalence, Results available
  CCEM- K6.a Comparison of AC/DC voltage transfer standards
1993 - 1999
Comparison type, Field   Key comparison in Electricity and Magnetism, AC Voltage, Current, Power, and AC/DC Transfer
Parameter(s)   Voltage: 3 V
Frequency: 1 kHz, 20 kHz, 100 kHz and 1 MHz
Status   Approved for equivalence, Results available
  APMP.EM- K6.a Comparison of AC/DC voltage transfer standards
2000 - 2003
Comparison type, Field   Key comparison in Electricity and Magnetism, AC Voltage, Current, Power, and AC/DC Transfer
Parameter(s)   Voltage: 3 V
Frequency: 1 kHz, 20 kHz, 100 kHz and 1 MHz
Status   Approved for equivalence, Results available
  APMP.M.P- K6 Pressure measurements in gas (gauge mode)
1998 - 2001
Comparison type, Field   Key comparison in Mass, Pressure
Effective area of a piston-cylinder unit
Parameter(s)   Pressure: 20 kPa to 105 kPa
Status   Approved for equivalence, Results available
  APMP.M.P- K7 Pressure measurements in oil (gauge mode)
2002 - 2004
Comparison type, Field   Key comparison in Mass, Pressure
Pressure: 10 MPa to 100 MPa
Status   Approved for equivalence, Results available
  CCQM- K8 Monoelemental calibration solutions of Al, Cu, Fe and Mg
1999 - 2000
Comparison type, Field   Key comparison in Amount of Substance, Inorganics
Status   Approved for equivalence, Results available
  EUROMET.EM- K11 AC/DC voltage transfer difference at low voltages
2005 - 2008
Comparison type, Field   Key comparison in Electricity and Magnetism, AC Voltage, Current, Power, and AC/DC Transfer
Parameter(s)   Voltage: 10 mV and 100 mV
Frequency: 1 kHz, 20 kHz, 100 kHz, and 1 MHz
Status   Approved for equivalence, Results available
  CCM.M- K5 Comparison of mass standards
2000 - 2003
Comparison type, Field   Key comparison in Mass, Mass Standards
Mass: 200 mg, 1 g, 50 g, 200 g and 2 kg
Status   Approved for equivalence, Results available
  CCM.P- K3 Pressure measurements in gas, ultra-high vacuum (absolute mode)
1998 - 2002
Comparison type, Field   Key comparison in Mass, Pressure
Pressure: 3 µPa to 0.9 mPa
Status   Approved for equivalence, Results available
  CCM.P- K9 Pressure measurements
1981 - 1987
Comparison type, Field   Key comparison in Mass, Pressure
Pressure: 0.1 mPa to 1000 mPa
Status   Approved for provisional equivalence
  CCM.P- K10 Pressure measurements
1983 - 1995
Comparison type, Field   Key comparison in Mass, Pressure
Pressure: 10 kPa to 140 kPa
Status   Approved for provisional equivalence
  CCM.V- K1.B2 Viscosity measurements of standard liquids
2002
Comparison type, Field   Key comparison in Mass, Viscosity
Standard liquid B2, kinematic viscosity: 400 mm2/s
Parameter(s)   Temperature: 40 °C
Status   Approved for equivalence, Results available
  APMP.AUV.A- K1 Comparison of laboratory standard microphone calibrations
2004 - 2005
Comparison type, Field   Key comparison in Acoustics, Ultrasound, and Vibration, Acoustics
Parameter(s)   Frequency: 63 Hz to 8 kHz
Status   Approved for equivalence, Results available
  APMP.M.M- K1 Comparison of mass standards
1999 - 2001
Comparison type, Field   Key comparison in Mass, Mass Standards
Mass: 1 kg
Status   Approved for equivalence, Results available
  APMP.M.P- K1.c Pressure measurements in gas (gauge mode)
1998 - 2001
Comparison type, Field   Key comparison in Mass, Pressure
Effective area of a piston-cylinder unit
Parameter(s)   Pressure: 0.4 MPa to 4.0 MPa
Status   Approved for equivalence, Results available
  BIPM.EM- K13.b Comparison of resistance standards
1993 -
Comparison type, Field   Key comparison in Electricity and Magnetism, Resistance
Resistance: 10 kiloohms
Status   Ongoing, approved for equivalence, Results available
  CCEM- K6.c Comparison of AC/DC voltage transfer standards at high frequencies
1995 - 1999
Comparison type, Field   Key comparison in Electricity and Magnetism, AC Voltage, Current, Power, and AC/DC Transfer
Parameter(s)   Voltage: 3 V and 4 V
Frequency: 0.5 MHz, 1 MHz, 10 MHz, 30 MHz, 50 MHz, 70 MHz and 100 MHz
Status   Approved for equivalence, Results available
  CCEM.RF- K5.b.CL Reflection coefficient / S parameters in type N connectors
2003 - 2006
Comparison type, Field   Key comparison in Electricity and Magnetism, Radio frequencies
Parameter(s)   Frequency: 2 GHz to 18 GHz
Status   Approved for equivalence, Results available
  CCEM.RF- K13.CL Voltage measurements
Comparison type, Field   Key comparison in Electricity and Magnetism, Radio frequencies
Voltage: 1 mV
Parameter(s)   Frequency: 30 MHz
Status   Approved for provisional equivalence