United Kingdom, TUVNEL (TUVNEL)
Complete CMCs in Mass and related quantities for United Kingdom (.PDF file)
Liquid flowing quantity: mass or volume. Any flow measurement instrument or flow device, 0.002 L/min to 5 L/min
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.05
Pulsed, electrical, digital and optical outputs; various methods
Fluid: kerosine, gas-oil, velocite, water, any safe liquid
Viscosity: up to 30 cSt
Temperature: ambient
Pressure: 0 MPa to 0.5 MPa
Approved on 15 October 2013
Internal NMI service identifier: UK1
 
Liquid flowing quantity: mass or volume. Any flow measurement instrument or flow device, 0.04 L/s to 100 L/s
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.03
Pulsed, electrical, digital and optical outputs; various methods
Fluid: kerosine, gas-oil, mineral oils
Viscosity: 2.2 cSt to 30 cSt
Temperature: 5 °C to 50 °C
Pressure: 0 MPa to 0.8 MPa
Pipe up to 200 mm
Approved on 15 October 2013
Internal NMI service identifier: UK2
 
Liquid flowing quantity: mass or volume. Any flow measurement instrument or flow device, 0.04 L/s to 100 L/s
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.05
Pulsed, electrical, digital and optical outputs; various methods
Fluid: heavy oil
Viscosity: 30 cSt and 500 cSt
Temperature: 5 °C to 50 °C
Pressure: 0 MPa to 0.8 MPa
Pipe up to 200 mm
Approved on 15 October 2013
Internal NMI service identifier: UK3
 
Liquid flowing quantity: mass or volume. Any flow measurement instrument or flow device, 0.04 L/s to 200 L/s
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.08
Pulsed, electrical, digital and optical outputs; various methods
Fluid: kerosine, gas-oil, mineral oils
Viscosity: 2.2 cSt to 30 cSt
Temperature: 5 °C to 50 °C
Pressure: 0 MPa to 0.8 MPa
Pipe up to 200 mm
Approved on 15 October 2013
Internal NMI service identifier: UK4
 
Liquid flowing quantity: mass or volume. Any flow measurement instrument or flow device, 0.04 L/s to 150 L/s
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.25
Pulsed, electrical, digital and optical outputs; various methods
Fluid: heavy oil
Viscosity: 30 cSt to 500 cSt
Temperature: 5 °C to 50 °C
Pressure: 0 MPa to 0.8 MPa
Pipe up to 200 mm
Approved on 15 October 2013
Internal NMI service identifier: UK5
 
Volume liquidhydrocarbon flowrate. Any flow measurement instrument or flow device, 0.5 L/s to 100 L/s
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.08
Pulsed, electrical, digital and optical outputs; various methods
Fluid: Crown oil
Viscosity: 1.5 cP to 10 cP
Temperature: 20 °C to 80 °C
Pressure: 0.5 MPa to 9.4 MPa
Also Mass hydrocarbon flow rate
Approved on 17 November 2017
Internal NMI service identifier: UK8