Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs Chemistry (7)
CHEMICAL MATERIAL >
polypropylene, polyethylene and polyvinyl chloride
cereal and cereal products (2)
botanical materials (1)
drinking water, fresh water (1)
rice and rice flour (1)
soybean and soybean powder (1)
CHEMICAL ANALYTE
cadmium (7)
GEOGRAPHIC LOCATION
APMP (7)
Thailand (7)
Result of the search
Your query 'NIMT' produced 7 results New search

Thailand, NIMT (National Institute of Metrology (Thailand))
Complete CMCs in Chemistry for Biological fluids and materials for Thailand (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95 %) in %
botanical materials cadmium 0.1 to 20 3.5 to 4.0
Mechanism(s) for measurement service delivery: Provision of reference values for both PT and RM samples
Uncertainty convention 1.
Approved on 19 June 2014.
Internal NMI service identifier: NIMT/12021-60201

Thailand, NIMT (National Institute of Metrology (Thailand))
Complete CMCs in Chemistry for Food for Thailand (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95 %) in %
rice and rice flour cadmium 0.1 to 1.0 3.5 to 4.0
Mechanism(s) for measurement service delivery: Provision of reference values for PT schemes and reference material producer
Uncertainty convention 1.
Approved on 06 September 2012.
Internal NMI service identifier: NIMT/12020-60205

Thailand, NIMT (National Institute of Metrology (Thailand))
Complete CMCs in Chemistry for Advanced materials for Thailand (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95%) in %
poly(acrylonitrile butadiene styrene) and polystyrene cadmium 1 to 100 1.5 to 2.0
Mechanism(s) for measurement service delivery: Provision of reference values for both PT and RM samples
Uncertainty convention 1.
Approved on 19 June 2014.
Internal NMI service identifier: NIMT/12021-60210

Thailand, NIMT (National Institute of Metrology (Thailand))
Complete CMCs in Chemistry for Food for Thailand (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95 %) in %
soybean and soybean powder cadmium 0.1 to 1.0 3.5 to 4.0
Mechanism(s) for measurement service delivery: Provision of reference values for PT schemes and reference material producer
Uncertainty convention 1.
Approved on 06 September 2012.
Internal NMI service identifier: NIMT/12020-60206

Thailand, NIMT (National Institute of Metrology (Thailand))
Complete CMCs in Chemistry for Food for Thailand (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95 %) in %
cereal and cereal products cadmium 0.1 to 1.0 3.5 to 4.0
Mechanism(s) for measurement service delivery: Provision of reference values for PT schemes and reference material producer
Uncertainty convention 1.
Approved on 06 September 2012.
Internal NMI service identifier: NIMT/12020-60204

Thailand, NIMT (National Institute of Metrology (Thailand))
Complete CMCs in Chemistry for Water for Thailand (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95 %) in %
drinking water, fresh water cadmium 0.001 to 1.000 4.5 to 5.0
Mechanism(s) for measurement service delivery: Provision of reference values for both PT and RM samples
Uncertainty convention 1.
Approved on 30 August 2017.
Internal NMI service identifier: NIMT/12022-60304

Thailand, NIMT (National Institute of Metrology (Thailand))
Complete CMCs in Chemistry for Food for Thailand (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95 %) in %
cereal and cereal products cadmium 0.1 to 0.5 4.6 to 5.0
Mechanism(s) for measurement service delivery: Provision of reference values for both in-house and external PT/RM samples
Uncertainty convention 1.
Approved on 20 January 2016.
Internal NMI service identifier: NIMT/12021-60211