Your query 'United Kingdom' produced 9 results New search

 
United Kingdom, NMRO (National Measurement and Regulation Office)
Complete CMCs in Mass and related quantities for United Kingdom (.PDF file)
Volume. Micropipettes, 0.02 mL to 5 mL
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1 to 0.09
Gravimetric
Temperature: 20 °C
Delivered volume
Internal NMI service identifier: UK39
 
Volume. Glassware, pipettes, automatic pipettes, etc., 0.002 L to 20 L
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.02 to 0.008
Gravimetric
Temperature: 20 °C
Delivered volume
Internal NMI service identifier: UK40
 
Volume. Metal delivery measures, 1 L to 500 L
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.008
Gravimetric
Temperature: 20 °C
Delivered volume
Internal NMI service identifier: UK41
 
Volume. Metal or glass measures or artefacts, 0.001 L to 500 L
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.02 to 0.008
Gravimetric
Temperature: 20 °C
Contained volume
Internal NMI service identifier: UK42
 
Volume. Metal or glass measures or artefacts, 0.005 L to 20 L
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.02
Volumetric
Temperature: 20 °C
Contained volume
Internal NMI service identifier: UK43
 
Volume. Metal proving tanks, 10 L to 10000 L
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.01
Volumetric
Temperature: 20 °C
Contained volume
Internal NMI service identifier: UK44
 
United Kingdom, TUVNEL (TUVNEL)
Complete CMCs in Mass and related quantities for United Kingdom (.PDF file)
Liquid flowing quantity: mass and volume. Any flow measurement instrument or flow device, 0.1 L/s to 200 L/s
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.1
Pulsed, electrical, digital and optical outputs; various methods
Fluid: water
Temperature: 15 °C to 40 °C
Pressure: 0 MPa to 1 MPa
Pipe up to 1000 mm
Approved on 15 October 2013
Internal NMI service identifier: UK6
 
Liquid flowing quantity: mass and volume. Any flow measurement instrument or flow device, 0.1 L/s to 400 L/s
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.15
Pulsed, electrical, digital and optical outputs; various methods
Fluid: water
Temperature: 15 °C to 40 °C
Pressure: 0 MPa to 1 MPa (0.1 l/s to 200 l/s)
Pressure: 0 MPa to 0.5 MPa (200 l/s to 400 l/s)
Pipe up to 1000 mm
Approved on 15 October 2013
Internal NMI service identifier: UK7
 
Volume liquidhydrocarbon flowrate. Any flow measurement instrument or flow device, 0.5 L/s to 100 L/s
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.08
Pulsed, electrical, digital and optical outputs; various methods
Fluid: Crown oil
Viscosity: 1.5 cP to 10 cP
Temperature: 20 °C to 80 °C
Pressure: 0.5 MPa to 9.4 MPa
Also Mass hydrocarbon flow rate
Approved on 17 November 2017
Internal NMI service identifier: UK8