Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs Ionizing Radiation
CMCs General Physics (492)
CMCs Chemistry (438)
PHYSICS >
Properties of materials (65)
Temperature (56)
Properties of detectors and sources (55)
Radio frequency measurements (50)
Dimensional metrology (45)
Materials (43)
AC voltage, current, and power (20)
Electric and magnetic fields (18)
Fluid flow (14)
Impedance up to the MHz range (13)
Photometry (11)
Sound in water (11)
CHEMICAL MATERIAL >
nitrogen (177)
methane (44)
synthetic air (19)
nitrogen or air (15)
monoelemental solution (14)
CHEMICAL ANALYTE >
methane
carbon dioxide (13)
carbon monoxide (12)
propane (12)
ethane (9)
sulfur dioxide (8)
GEOGRAPHIC LOCATION
EURAMET (930)
United Kingdom (930)
Result of the search
Your query 'United Kingdom' produced 930 results New search
[Prev] 2  3  4 [Next >>]

 
United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Photometry and Radiometry for United Kingdom (.PDF file)
Radiance factor. General material, 0.25 % to 300000 %
Absolute expanded uncertainty (k = 2, level of confidence 95 %): (0.01% + 0.0034R)
Reference reflectometer
Wavelength range: 350 nm to 400 nm
Bandwidth: 10 nm to 20 nm
Uncertainty values are for 0/45 geometry and white Spectralon. Uncertainty varies with scattering geometry and angular dependence of scattering properties of material
Approved on 07 May 2007
 
Radiance factor. General material, 0.1 % to 300000 %
Absolute expanded uncertainty (k = 2, level of confidence 95 %): (0.01% + 0.0019R)
Reference reflectometer
Wavelength range: 400 nm to 1000 nm
Bandwidth: 10 nm to 20 nm
Uncertainty values are for 0/45 geometry and white Spectralon. Uncertainty varies with scattering geometry and angular dependence of scattering properties of material
Approved on 07 May 2007
 
Wavelength. Spectrally-selective transmitting material, 200 nm to 2500 nm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in nm: 0.1
Scanning spectrophotometer
Wavelength range: 200 nm to 2500 nm
Bandwidth: 0.1 nm to 5 nm
Approved on 07 May 2007
 
Wavenumber. Spectrally-selective transmitting material, 1028 cm-1 to 3060 cm-1
Absolute expanded uncertainty (k = 2, level of confidence 95%) in cm-1: 0.2 to 0.3 (depending on wavenumber)
Scanning spectrophotometer
Wavenumber values: 3060 cm-1, 2850 cm-1, 1943 cm-1, 1601 cm-1, 1583 cm-1, 1154 cm-1, 1028 cm-1
Bandwidth: 2 cm-1 to 10 cm-1
Approved on 07 May 2007
 
Correlated colour temperature. Tungsten lamp, 2000 K to 3200 K
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in K: 10
Reference lamps and spectroradiometer
Other types of source can also be calibrated at higher uncertainty levels (uncertainty depends on the spectral characteristics of the source) Approved on 20 April 2017
 
Correlated colour temperature response. Colour temperature meter. Measurand unit, reading/K
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in K: 10
Tungsten reference lamps
Correlated colour temperature: 2000 K to 3200 K
Calibrations can also be carried out at correlated colour temperatures used for visual displays e.g. 6500 K (uncertainty associated such calibrations is higher and depends on the source used) Approved on 20 April 2017
 
Colour, emitted, x, y. General source, 0 to 0.9
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.0008 to 0.0001, varies with measurand
Spectroradiometer and reference lamps
Bandwidth: < 20 nm
Type of source: any source, including displays
The uncertainty varies according to the source properties; the quoted uncertainty applies for tungsten sources. Results can also be expressed in other units e.g. u, v or Lab
 
Colour, emitted, u, v. General source. u, v, 0 to 0.9
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.0004
Spectroradiometer and reference lamps
Bandwidth: < 20 nm
Type of source: any source, including displays
Uncertainty varies according to source properties. Results can also be expressed in other units e.g. x, y or Lab.
Approved on 07 May 2007
 
Colour, emitted, u, v. General source. u, v, 0 to 0.9
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.0001
Spectroradiometer and reference lamps
Bandwidth: selected to suit source type
Type of source: any source, including displays
Uncertainty varies according to source properties. Results can also be expressed in other units e.g. x, y or Lab.
Approved on 07 May 2007
 
Colour, emitted, u-prime, v-prime. General source, 0 to 0.9
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.0004
Spectroradiometer and reference lamps
Bandwidth: < 20 nm
Type of source: any source, including displays
Uncertainty varies according to source properties. Results can also be expressed in other units e.g. x, y or Lab.
Approved on 07 May 2007
 
Colour, emitted, u-prime, v-prime. General source, 0 to 0.9
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.0001
Spectroradiometer and reference lamps
Bandwidth: selected to suit source type
Type of source: any source, including displays
Uncertainty varies according to source properties. Results can also be expressed in other units e.g. x, y or Lab.
Approved on 07 May 2007
 
Colour, surface, x, y, Y. General material, x, y = 0 to x, y = 0.9
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.0002
Integrating sphere spectrophotometer
Specific measurement conditions: 0/d, 2 nm bandwidth
Type of material: non-fluorescent
Approved on 07 May 2007
 
Colour, surface, x, y, Y. General material, Y = 0 to Y = 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): (0.0005 + 0.0035Y)
Integrating sphere spectrophotometer
Specific measurement conditions: 0/d, 2 nm bandwidth
Type of material: non-fluorescent
Approved on 07 May 2007
 
Colour, surface, x, y, Y. Fluorescent material, x, y = 0 to x, y = 0.9
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.003
Reference spectrofluorimeter
Type of source used: monochromator
Specific measurement conditions: 0/45
Type of fluorescent material: general
Approved on 07 May 2007
 
Colour, surface, x, y, Y. Fluorescent material, Y = 0 to Y = 300
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.003
Reference spectrofluorimeter
Type of source used: monochromator
Specific measurement conditions: 0/45
Type of fluorescent material: general
Approved on 07 May 2007
 
Colour, surface, x, y, Y. Diffusely reflecting material, x, y = 0 to x, y = 0.9
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.0002
Integrating sphere spectrophotometer
Specific measurement conditions: 0/d, 2 nm bandwidth
Other types of material can also be calibrated
Approved on 07 May 2007
 
Colour, surface, x, y, Y. Diffusely reflecting material, Y = 0 to Y = 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): (0.0005 + 0.0035Y)
Integrating sphere spectrophotometer
Specific measurement conditions: 0/d, 2 nm bandwidth
Other types of material can also be calibrated
Approved on 07 May 2007
 
Colour, surface, L*a*b*. General material, L* = 0 to L* = 100
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.15
Integrating sphere spectrophotometer
Specific measurement conditions: 0/d, 2 nm bandwidth
Type of material: non-fluorescent
Approved on 07 May 2007
 
Colour, surface, L*a*b*. General material, a*, b* = -200 to a*, b* = 200
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.1
Integrating sphere spectrophotometer
Specific measurement conditions: 0/d, 2 nm bandwidth
Type of material: non-fluorescent
Approved on 07 May 2007
 
Colour, surface, L*a*b*. Fluorescent material, L* = 0 to L* = 160
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.003
Reference spectrofluorimeter
Irradiation conditions: monochromator
Specific measurement conditions: 0/45
Type of fluorescent material: general
Approved on 07 May 2007