Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs Chemistry (450)
CMCs General Physics (386)
CMCs Ionizing Radiation (187)
PHYSICS >
Radio frequency measurements
Temperature
Properties of materials (65)
Properties of detectors and sources (55)
Dimensional metrology (45)
Materials (43)
AC voltage, current, and power (20)
Electric and magnetic fields (18)
Fluid flow (14)
Impedance up to the MHz range (13)
Photometry (11)
Sound in water (11)
DC voltage, current, and resistance (11)
Pressure (11)
IONIZING RADIATION >
Activity (76)
Activity per unit mass (31)
Absorbed dose to water (15)
Fluence rate (14)
Emission rate (10)
Air kerma (10)
Surface emission rate (7)
Ambient dose equivalent rate (6)
Personal dose equivalent rate (6)
Emission anisotropy (6)
CHEMICAL MATERIAL >
nitrogen (180)
methane (43)
synthetic air (26)
nitrogen or air (17)
monoelemental solution (14)
CHEMICAL ANALYTE >
ethane
methane (21)
carbon dioxide (13)
carbon monoxide (12)
propane (12)
sulfur dioxide (8)
GEOGRAPHIC LOCATION
EURAMET (1023)
United Kingdom (1016)
Denmark (7)
Result of the search
Your query 'United Kingdom' produced more than 1000 results New search
[<< Prev] 50

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
hydrogen water 0.05 to 20 15.0
Mechanism(s) for measurement service delivery: Calibration
Approved on 28 June 2016.
Internal NMI service identifier: NPL/67 rev
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
hydrogen water 20 to 100 25.0
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: NPL/67 rev
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
hydrogen total hydrocarbon compounds 0.01 to 100 30 to 1.5
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: NPL/67 rev
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
hydrogen oxygen 0.01 to 500 25 to 1.5
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: NPL/67 rev
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
hydrogen helium 20 to 500 5 to 2
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: NPL/67 rev
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
hydrogen nitrogen 0.01 to 500 25 to 1.5
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: NPL/67 rev
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
hydrogen argon 0.01 to 500 25 to 1.5
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: NPL/67 rev
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
hydrogen carbon dioxide 0.01 to 500 25 to 1.5
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: NPL/67 rev
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
hydrogen carbon monoxide 0.01 to 500 25 to 1.5
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: NPL/67 rev
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
hydrogen total sulfur compounds 0 to 10 30 to 2
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: NPL/67 rev
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen or air carbon dioxide 0.012 to 10.0 100.0 to 0.12 0.012 to 10.0 100.0 to 0.12
Mechanism(s) for measurement service delivery: PRGM and calibration
Approved on 30 June 2017.
Internal NMI service identifier: NPL/GA01

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen or air carbon dioxide 10.0 to 5.00E+05 0.12 10.0 to 5.00E+05 0.12
Mechanism(s) for measurement service delivery: PRGM and calibration
Approved on 30 June 2017.
Internal NMI service identifier: NPL/GA02

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen or air methane 0.0036 to 1.8 100.0 to 0.2 0.0036 to 1.8 100.0 to 0.2
Mechanism(s) for measurement service delivery: PRGM and calibration
Approved on 30 June 2017.
Internal NMI service identifier: NPL/GA05

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen or air methane 1.7994 to 5.00E+05 0.2 1.7994 to 5.00E+05 0.2
Mechanism(s) for measurement service delivery: PRGM and calibration
Approved on 30 June 2017.
Internal NMI service identifier: NPL/GA06

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen nitrogen monoxide 0.1 to 0.444 4.4 to 1 0.1 to 0.444 4.4 to 1.0
Mechanism(s) for measurement service delivery: PRGM and calibration
Approved on 30 June 2017.
Internal NMI service identifier: NPL/GA07

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen nitrogen monoxide 0.4441 to 1.4 1.0 to 1 0.444 to 1.4 1.0
Mechanism(s) for measurement service delivery: PRGM and calibration
Approved on 30 June 2017.
Internal NMI service identifier: NPL/GA08

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen nitrogen monoxide 1.4 to 10 1.0 to 0.14 1.4 to 10.0 1.0 to 0.14
Mechanism(s) for measurement service delivery: PRGM and calibration
Approved on 30 June 2017.
Internal NMI service identifier: NPL/GA09

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen nitrogen monoxide 10 to 5.00E+05 0.14 10.0 to 5.00E+05 0.14
Mechanism(s) for measurement service delivery: PRGM and calibration
Approved on 30 June 2017.
Internal NMI service identifier: NPL/GA10

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen oxygen 0.0097 to 10 100.0 to 0.1 0.0097 to 10.0 100.0 to 0.1
Mechanism(s) for measurement service delivery: PRGM and calibration
Approved on 30 June 2017.
Internal NMI service identifier: NPL/GA11

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen oxygen 10 to 5.00E+05 0.1 10.0 to 5.00E+05 0.1
Mechanism(s) for measurement service delivery: PRGM and calibration
Approved on 30 June 2017.
Internal NMI service identifier: NPL/GA12