Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (492)
CMCs Chemistry (459)
CMCs Ionizing Radiation (180)
PHYSICS >
Properties of materials (65)
Temperature (56)
Properties of detectors and sources (55)
Radio frequency measurements (50)
Dimensional metrology (45)
Materials (43)
AC voltage, current, and power (20)
Electric and magnetic fields (18)
Fluid flow (14)
Impedance up to the MHz range (13)
Photometry (11)
Sound in water (11)
IONIZING RADIATION >
Surface emission rate
Activity (76)
Activity per unit mass (31)
Absorbed dose to water (15)
Fluence rate (14)
Emission rate (10)
Air kerma (10)
Ambient dose equivalent rate (6)
Personal dose equivalent rate (6)
Emission anisotropy (6)
Activity per unit volume (2)
CHEMICAL MATERIAL >
nitrogen (183)
methane (44)
synthetic air (27)
nitrogen or air (17)
monoelemental solution (14)
CHEMICAL ANALYTE >
methane (21)
carbon dioxide (13)
carbon monoxide (12)
propane (12)
ethane (9)
GEOGRAPHIC LOCATION
EURAMET (1131)
United Kingdom (1124)
Denmark (7)
Result of the search
Your query 'United Kingdom' produced more than 1000 results New search
[<< Prev] 3  4  5 [Next >>]

 
United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Photometry and Radiometry for United Kingdom (.PDF file)
Colour, surface, L*a*b*. Fluorescent material, a*, b* = -200 to a*, b* = 200
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 1.2
Reference spectrofluorimeter
Irradiation conditions: monochromator
Specific measurement conditions: 0/45
Type of fluorescent material: general
Approved on 07 May 2007
 
Colour, surface, L*a*b*. Diffusely reflecting material, L* = 0 to L* = 100
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.15
Integrating sphere spectrophotometer
Specific measurement conditions: 0/d, 2 nm bandwidth
Other types of material can also be calibrated
Approved on 07 May 2007
 
Colour, surface, L*a*b*. Diffusely reflecting material, a*, b* = -200 to a*, b* = 200
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.1
Integrating sphere spectrophotometer
Specific measurement conditions: 0/d, 2 nm bandwidth
Other types of material can also be calibrated
Approved on 07 May 2007
 
Colour, transmitted, x, y, Y. General material, x, y = 0 to x, y = 0.9
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.0002
Spectrophotometer
Specific measurement conditions: regular transmittance geometry
Type of material: non-fluorescent
 
Colour, transmitted, x, y, Y. General material, Y = 0 to Y = 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.003
Spectrophotometer
Specific measurement conditions: regular transmittance geometry
Type of material: non-fluorescent
 
Colour, transmitted, L*a*b*. General material, L* = 0 to L* = 100
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.05
Spectrophotometer
Specific measurement conditions: regular transmittance geometry
Type of material: non-fluorescent
 
Colour, transmitted, L*a*b*. General material, a*, b* = -200 to a*, b* = 200
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.05
Spectrophotometer
Specific measurement conditions: regular transmittance geometry
Type of material: non-fluorescent
 
Wavelength. Fibre optic source, 800 nm to 1700 nm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in nm: 0.3
Spectrum analyser
 
Wavelength. Optical spectrum analyser, 600 nm to 1700 nm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in pm: 34
Lamp / wavemeter / transition locked laser
Measurements can be made at specified wavelengths within this range, depending on the availability of a suitable laser source. The uncertainty will depend on the properties of the OSA under calibration.
 
Transmittance, regular, spectral. Spectrally-neutral material, 1E-03 to 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 3E-05 to 3.5E-04, varies as the logarithm of the measurand
Reference spectrophotometer
Wavelength: 250 nm to 749 nm
Bandwidth: < 3 nm
 
Transmittance, regular, spectral. Spectrally-neutral material, 1E-03 to 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 1E-05 to 4.5E-04, varies as the logarithm of the measurand
Reference spectrophotometer
Wavelength: 750 nm to 2500 nm
Bandwidth: < 3 nm
 
Transmittance, regular, spectral. Spectrally-neutral material, 1E-03 to 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.0017 at 0.73
Scanning spectrophotometer
Wavenumber: 3990 cm-1
Bandwidth: 2 cm-1 to 15 cm-1
Specific measurement conditions: measured at 5 ° and f/6. Values calculated for normal incidence and a range of f/n's.
Other types of material can also be calibrated. Uncertainties at other transmittance values available on request.
Approved on 07 May 2007
 
Transmittance, regular, spectral. Spectrally-neutral material, 1E-03 to 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.00065 at 0.14
Scanning spectrophotometer
Wavenumber: 3512 cm-1
Bandwidth: 2 cm-1 to 15 cm-1
Specific measurement conditions: measured at 5 ° and f/6. Values calculated for normal incidence and a range of f/n's.
Other types of material can also be calibrated. Uncertainties at other transmittance values available on request.
Approved on 07 May 2007
 
Transmittance, regular, spectral. Spectrally-neutral material, 1E-03 to 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.0011 at 0.36
Scanning spectrophotometer
Wavenumber: 3031 cm-1
Bandwidth: 2 cm-1 to 15 cm-1
Specific measurement conditions: measured at 5 ° and f/6. Values calculated for normal incidence and a range of f/n's.
Other types of material can also be calibrated. Uncertainties at other transmittance values available on request.
Approved on 07 May 2007
 
Transmittance, regular, spectral. Spectrally-neutral material, 1E-03 to 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.00052 at 0.06
Scanning spectrophotometer
Wavenumber: 2739 cm-1
Bandwidth: 2 cm-1 to 15 cm-1
Specific measurement conditions: measured at 5 ° and f/6. Values calculated for normal incidence and a range of f/n's.
Other types of material can also be calibrated. Uncertainties at other transmittance values available on request.
Approved on 07 May 2007
 
Transmittance, regular, spectral. Spectrally-neutral material, 1E-03 to 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.00079 at 0.17
Scanning spectrophotometer
Wavenumber: 2598 cm-1
Bandwidth: 2 cm-1 to 15 cm-1
Specific measurement conditions: measured at 5 ° and f/6. Values calculated for normal incidence and a range of f/n's.
Other types of material can also be calibrated. Uncertainties at other transmittance values available on request.
Approved on 07 May 2007
 
Transmittance, regular, spectral. Spectrally-neutral material, 1E-03 to 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.00064 at 0.10
Scanning spectrophotometer
Wavenumber: 2473 cm-1
Bandwidth: 2 cm-1 to 15 cm-1
Specific measurement conditions: measured at 5 ° and f/6. Values calculated for normal incidence and a range of f/n's.
Other types of material can also be calibrated. Uncertainties at other transmittance values available on request.
Approved on 07 May 2007
 
Transmittance, regular, spectral. Spectrally-neutral material, 1E-03 to 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.0001 at 0.0001
Scanning spectrophotometer
Wavenumber: 2010 cm-1
Bandwidth: 2 cm-1 to 15 cm-1
Specific measurement conditions: measured at 5 ° and f/6. Values calculated for normal incidence and a range of f/n's.
Other types of material can also be calibrated. Uncertainties at other transmittance values available on request.
Approved on 07 May 2007
 
Transmittance, diffuse, spectral. Spectrally-neutral material, 0 to 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.01
Spectrophotometer with integrating sphere accessory
Wavelength range: 200 nm to 800 nm
Bandwidth: 0.5 nm to 2 nm
Specific measurement conditions: 0/d
Other types of material can also be calibrated
 
Transmittance, diffuse, spectral. Spectrally-neutral material, 0 to 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.01
Spectrophotometer with integrating sphere accessory
Wavelength range: 800 nm to 2500 nm
Bandwidth: 2 nm to 20 nm
Specific measurement conditions: 0/d
Other types of material can also be calibrated