Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs Chemistry (459)
CMCs General Physics (427)
CMCs Ionizing Radiation (187)
PHYSICS >
Properties of materials
Temperature (56)
Properties of detectors and sources (55)
Radio frequency measurements (50)
Dimensional metrology (45)
Materials (43)
AC voltage, current, and power (20)
Electric and magnetic fields (18)
Fluid flow (14)
Impedance up to the MHz range (13)
Photometry (11)
Sound in water (11)
DC voltage, current, and resistance (11)
IONIZING RADIATION >
Activity (76)
Activity per unit mass (31)
Absorbed dose to water (15)
Fluence rate (14)
Emission rate (10)
Air kerma (10)
Surface emission rate (7)
Ambient dose equivalent rate (6)
Personal dose equivalent rate (6)
Emission anisotropy (6)
CHEMICAL MATERIAL >
nitrogen (183)
methane (44)
synthetic air (27)
nitrogen or air (17)
monoelemental solution (14)
CHEMICAL ANALYTE >
methane (21)
carbon dioxide (13)
carbon monoxide (12)
propane (12)
ethane (9)
GEOGRAPHIC LOCATION
EURAMET (1073)
United Kingdom (1066)
Denmark (7)
Result of the search
Your query 'United Kingdom' produced more than 1000 results New search
[Prev] 2  3  4 [Next >>]

 
United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Photometry and Radiometry for United Kingdom (.PDF file)
Luminous intensity. Tungsten lamp, 1 cd to 10000 cd
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.5 to 0.4, varies with colour temperature
Photometric bench and reference lamps / photometer
Colour temperature: 2000 K to 2856 K
 
Luminous intensity. Tungsten lamp, 1 cd to 10000 cd
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.4 to 0.5, varies with colour temperature
Photometric bench and reference lamps / photometer
Colour temperature: 2856 K to 3200 K
 
Illuminance responsivity, tungsten source. Illuminance meter. Measurand unit, A/lx, V/lx, reading/lx
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.5 to 0.4, varies with illuminance
Photometric bench and reference lamps / photometer
Illuminance: 0.1 lx to 8 lx
Colour temperature: 2856 K
Approved on 20 April 2017
 
Illuminance responsivity, tungsten source. Illuminance meter. Measurand unit, A/lx, V/lx, reading/lx
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.4
Photometric bench and reference lamps / photometer
Illuminance: 8 lx to 500 lx
Colour temperature: 2856 K
Approved on 20 April 2017
 
Illuminance responsivity, tungsten source. Illuminance meter. Measurand unit, A/lx, V/lx, reading/lx
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.4 to 1.0, varies with illuminance
Photometric bench and reference lamps / photometer
Illuminance: 500 lx to 50000 lx
Colour temperature: 2856 K
Approved on 20 April 2017
 
Luminous flux. Tungsten lamp, 1 lm to 100 lm
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.7 to 0.6, varies with measurand
Integrating sphere or goniophotometer
Colour temperature: 2000 K to 3200 K
 
Luminous flux. Tungsten lamp, 100 lm to 20000 lm
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.6
Integrating sphere or goniophotometer
Colour temperature: 2000 K to 3200 K
 
Illuminance. Tungsten lamp, 0.1 lx to 50000 lx
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.5
Photometric bench and reference lamps / photometer
Correlated colour temperature: 2000 K to 3200 K
 
Luminance. Tungsten-based source, 1 cd/m2 to 20000 cd/m2
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.0
Telephotometer and reference lamp / calibrated diffuser combination
Correlated colour temperature: 2700 K to 3200 K
 
Luminance responsivity. Luminance meter. Measurand unit, A/(cd m-2), V/(cd m-2), reading/(cd m-2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.5
Reference lamp / diffuser combination
Luminance: 1E-04 cd/m2 to 1 cd/m2
Type of source used: tungsten reference lamp / diffuser combination
 
Luminance responsivity. Luminance meter. Measurand unit, A/(cd m-2), V/(cd m-2), reading/(cd m-2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.0
Reference lamp / diffuser combination
Luminance: 1 cd/m2 to 20000 cd/m2
Type of source used: tungsten reference lamp / diffuser combination
Other types of source can also be used
 
Responsivity, spectral, power. Broadband detector. Measurand unit, A/W, V/W, reading/W, W, dB, dBm
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 3.6 to 3.2, depending on wavelength
Double grating monochromator
Wavelength: 200 nm to 210 nm
Bandwidth: < 10 nm
Power level: < 20 µW
Approved on 20 April 2017
 
Responsivity, spectral, power. Broadband detector. Measurand unit, A/W, V/W, reading/W, W, dB, dBm
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.0
Double grating monochromator
Wavelength: 211 nm to 239 nm
Bandwidth: < 10 nm
Power level: < 20 µW
Approved on 20 April 2017
 
Responsivity, spectral, power. Broadband detector. Measurand unit, A/W, V/W, reading/W, W, dB, dBm
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.7 at 240 nm, 0.5 above 240 nm
Double grating monochromator
Wavelength: 240 nm to 315 nm
Bandwidth: < 10 nm
Power level: < 20 µW
Approved on 20 April 2017
 
Responsivity, spectral, power. Broadband detector. Measurand unit, A/W, V/W, reading/W, W, dB, dBm
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.3
Double grating monochromator
Wavelength: 316 nm to 404 nm
Bandwidth: < 10 nm
Power level: < 20 µW
Approved on 20 April 2017
 
Responsivity, spectral, power. Broadband detector. Measurand unit, A/W, V/W, reading/W, W, dB, dBm
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.1
Double grating monochromator
Wavelength: 405 nm to 919 nm
Bandwidth: < 10 nm
Power level: < 20 µW
Approved on 20 April 2017
 
Responsivity, spectral, power. Broadband detector. Measurand unit, A/W, V/W, reading/W, W, dB, dBm
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.3
Double grating monochromator
Wavelength: 920 nm to 1000 nm
Bandwidth: < 10 nm
Power level: < 20 µW
Approved on 20 April 2017
 
Responsivity, spectral, power. Broadband detector. Measurand unit, A/W, V/W, reading/W, W, dB, dBm
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.3
Double grating monochromator
Wavelength: 1001 nm to 1400 nm
Bandwidth: < 10 nm
Power level: < 20 µW
Approved on 20 April 2017
 
Responsivity, spectral, power. Broadband detector. Measurand unit, A/W, V/W, reading/W, W, dB, dBm
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.3 to 0.4 (depending on wavelength)
Double grating monochromator
Wavelength: 1401 nm to 1800 nm
Bandwidth: < 10 nm
Power level: < 20 µW
Approved on 20 April 2017
 
Responsivity, spectral, irradiance. Broad band detector. Measurand unit, A/(W m-2), V/(W m-2), reading/(W m-2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 3.2
Double grating monochromator
Wavelength: 200 nm to 210 nm
Bandwidth: < 10 nm
Power level: < 20 µW
Other types of detector can also be calibrated
Approved on 20 April 2017