Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs Chemistry (445)
CMCs General Physics (358)
CMCs Ionizing Radiation (187)
PHYSICS >
Properties of detectors and sources
Fluid flow
Properties of materials
Temperature (56)
Radio frequency measurements (50)
Dimensional metrology (45)
Materials (43)
AC voltage, current, and power (20)
Electric and magnetic fields (18)
Impedance up to the MHz range (13)
Photometry (11)
Sound in water (11)
DC voltage, current, and resistance (11)
Pressure (11)
Laser frequencies (10)
IONIZING RADIATION >
Activity (76)
Activity per unit mass (31)
Absorbed dose to water (15)
Fluence rate (14)
Emission rate (10)
Air kerma (10)
Surface emission rate (7)
Ambient dose equivalent rate (6)
Personal dose equivalent rate (6)
Emission anisotropy (6)
CHEMICAL MATERIAL >
monoelemental solution
nitrogen (183)
methane (44)
synthetic air (27)
nitrogen or air (17)
synthetic natural gas (12)
CHEMICAL ANALYTE >
methane (21)
carbon dioxide (13)
carbon monoxide (12)
propane (12)
ethane (9)
GEOGRAPHIC LOCATION
EURAMET (990)
United Kingdom (983)
Denmark (7)
Result of the search
Your query 'United Kingdom' produced 990 results New search
1  2  3 [Next >>]

 
United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Acoustics, Ultrasound, Vibration for United Kingdom (.PDF file)
Free-field sensitivity level. Reference measuring hydrophones/ projectors. Measurand unit, V/µPa
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.7
Three-transducer spherical wave reciprocity in a laboratory tank, IEC 565:1977
Frequency: 1 kHz to 2 kHz
Approved on 29 September 2004
Internal NMI service identifier: NPL/AW/10/01
 
Free-field sensitivity level. Reference measuring hydrophones/ projectors. Measurand unit, V/µPa
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.5
Three-transducer spherical wave reciprocity in a laboratory tank; IEC 565:1977
Frequency: 2 kHz to 500 kHz
Approved on 29 September 2004
Internal NMI service identifier: NPL/AW/10/01
 
Free-field sensitivity level. Reference measuring hydrophones. Measurand unit, V/µPa
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.9
Comparison with reference hydrophone, IEC 565:1977
Frequency: 1 kHz to 2 kHz
Approved on 29 September 2004
Internal NMI service identifier: NPL/AW/10/02
 
Free-field sensitivity level. Reference measuring hydrophones. Measurand unit, V/µPa
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.7
Comparison with reference hydrophone, IEC 565:1977
Frequency: 2 kHz to 1 MHz
Approved on 29 September 2004
Internal NMI service identifier: NPL/AW/10/02
 
Pressure sensitivity level. Reference measuring hydrophones. Measurand unit, V/µPa
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.5
Comparison with a calibrated reference microphone
Frequency: 25 Hz to 400 Hz
Approved on 29 September 2004
Internal NMI service identifier: NPL/AW/10/03
 
Free-field sensitivity. Hydrophone. Measurand unit, µV/Pa
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 6
Comparison with a secondary hydrophone in a non-linearly distorted sound field
Frequency: 1 MHz to 8 MHz
Approved on 29 September 2004
Internal NMI service identifier: NPL/AW/07/01
 
Free-field sensitivity. Hydrophone. Measurand unit, µV/Pa
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 7
Comparison with a secondary hydrophone in a non-linearly distorted sound field
Frequency: 9 MHz to 12 MHz
Approved on 29 September 2004
Internal NMI service identifier: NPL/AW/07/01
 
Free-field sensitivity. Hydrophone. Measurand unit, µV/Pa
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 8
Comparison with a secondary hydrophone in a non-linearly distorted sound field
Frequency: 13 MHz to 16 MHz
Approved on 29 September 2004
Internal NMI service identifier: NPL/AW/07/01
 
Free-field sensitivity. Hydrophone. Measurand unit, µV/Pa
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 11
Comparison with a secondary hydrophone in a non-linearly distorted sound field
Frequency: 17 MHz to 20 MHz
Approved on 29 September 2004
Internal NMI service identifier: NPL/AW/07/01
 
Ultrasonic power. Plane piston ultrasound transducer and generator, 0.0005 W to 1 W
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 2.5 to 6
Primary standard radiation force balance
Frequency: 0.8 MHz to 20 MHz
Approved on 29 September 2004
Internal NMI service identifier: NPL/AW/08/05
 
Ultrasonic power. Plane piston ultrasound transducer and generator, 0.50 W to 20 W
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 3.5 to 5
Calibrated radiation force balance
Frequency: 0.8 MHz to 3 MHz
Approved on 29 September 2004
Internal NMI service identifier: NPL/AW/08/05
 
Wavelength. Fibre optic source, 800 nm to 1700 nm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in nm: 0.3
Spectrum analyser
 
Wavelength. Optical spectrum analyser, 600 nm to 1700 nm
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in pm: 34
Lamp / wavemeter / transition locked laser
Measurements can be made at specified wavelengths within this range, depending on the availability of a suitable laser source. The uncertainty will depend on the properties of the OSA under calibration.
 
Luminous intensity. Tungsten lamp, 1 cd to 10000 cd
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.5 to 0.4, varies with colour temperature
Photometric bench and reference lamps / photometer
Colour temperature: 2000 K to 2856 K
 
Luminous intensity. Tungsten lamp, 1 cd to 10000 cd
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.4 to 0.5, varies with colour temperature
Photometric bench and reference lamps / photometer
Colour temperature: 2856 K to 3200 K
 
Illuminance responsivity, tungsten source. Illuminance meter. Measurand unit, A/lx, V/lx, reading/lx
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.5 to 0.4, varies with illuminance
Photometric bench and reference lamps / photometer
Illuminance: 0.1 lx to 8 lx
Colour temperature: 2856 K
Approved on 20 April 2017
 
Illuminance responsivity, tungsten source. Illuminance meter. Measurand unit, A/lx, V/lx, reading/lx
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.4
Photometric bench and reference lamps / photometer
Illuminance: 8 lx to 500 lx
Colour temperature: 2856 K
Approved on 20 April 2017
 
Illuminance responsivity, tungsten source. Illuminance meter. Measurand unit, A/lx, V/lx, reading/lx
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.4 to 1.0, varies with illuminance
Photometric bench and reference lamps / photometer
Illuminance: 500 lx to 50000 lx
Colour temperature: 2856 K
Approved on 20 April 2017
 
Luminous flux. Tungsten lamp, 1 lm to 100 lm
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.7 to 0.6, varies with measurand
Integrating sphere or goniophotometer
Colour temperature: 2000 K to 3200 K
 
Luminous flux. Tungsten lamp, 100 lm to 20000 lm
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.6
Integrating sphere or goniophotometer
Colour temperature: 2000 K to 3200 K