Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (18)
PHYSICS >
DC voltage, current, and resistance (18)
DC current sources: intermediate values (2)
DC voltage sources: single values (1)
DC voltage sources: low values (1)
DC voltage sources: intermediate values (1)
DC voltage meters: intermediate values (1)
DC voltage ratios: up to 1100 V (1)
DC resistance standards and sources: low values (1)
DC resistance standards and sources: high values (1)
DC resistance standards and sources: intermediate values (1)
DC resistance standards and sources: standards for high current (1)
DC resistance standards and sources: multiple ranges (1)
DC resistance meters: low values (1)
GEOGRAPHIC LOCATION
APMP (18)
Korea, Republic of (18)
Result of the search
Your query 'kriss' produced 18 results New search

 
Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Electricity and Magnetism for Korea, Republic of (.PDF file)
DC voltage sources: low values. Multifunction calibrator, 1.00E-05 V to 10 V
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µV: 0.05 to 10
Comparison with resistively divided voltage
Approved on 10 November 2014
Internal NMI service identifier: KRISS/1.1.2
Uncertainty table
 
DC resistance standards and sources: high values. Fixed resistor, 1.00E+07 to 1.00E+14
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 6 to 2600
DCC, Modified Wheatstone bridge
Temperature: 23 °C
Relative humidity: 40 % or less
Voltage: 10 V to 500 V
Approved on 10 November 2014
Internal NMI service identifier: KRISS/2.1.3
Uncertainty table
 
DC resistance standards and sources: standards for high current. DC shunt, 1 m to 100 m
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 5 to 50
DCC bridge
Current: 1 A to 100 A
Approved on 10 November 2014
Internal NMI service identifier: KRISS/2.1.4
Uncertainty table
 
DC resistance standards and sources: multiple ranges. Multifunction calibrator, 1 to 1.00E+08
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 10 to 41
Potentiometry transfer via multimeters
Approved on 10 November 2014
Internal NMI service identifier: KRISS/2.1.5
Uncertainty table
 
DC resistance meters: low values. Microhmmeters, resistance, 0.001 to 1
Relative expanded uncertainty (k = 2, level of confidence 95 %) in m/: 0.1 to 0.2
Direct calibration
Approved on 10 November 2014
Internal NMI service identifier: KRISS/2.2.1
Uncertainty table
 
DC resistance meters: intermediate values. Multimeter, resistance, 10 to 1E+08
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 3 to 30
Direct calibration
Approved on 10 November 2014
Internal NMI service identifier: KRISS/2.2.2
Uncertainty table
 
DC resistance meters: high values. Teraohmmeter, resistance, 1E+09 to 1E+14
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 70 to 6000
Direct calibration
Approved on 10 November 2014
Internal NMI service identifier: KRISS/2.2.3
Uncertainty table
 
DC current sources: intermediate values. Multifunction calibrator: DC current, 0.0002 A to 2 A
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µA/A: 6
Potentiometry
Approved on 10 November 2014
Internal NMI service identifier: KRISS/3.1.2
 
DC current sources: intermediate values. Current generator, 2 A to 20 A
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µA/A: 10
Potentiometry
Approved on 10 November 2014
Internal NMI service identifier: KRISS/3.1.2
 
DC current sources: high values. Current generator, 20 A to 100 A
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µA/A: 160
Potentiometry
Approved on 10 November 2014
Internal NMI service identifier: KRISS/3.1.3
 
DC current meters: low values. Pico-ammeter, 0.002 nA to 1.00E+05 nA
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µA/A: 1300 to 20
Direct calibration
Approved on 10 November 2014
Internal NMI service identifier: KRISS/3.2.1
Uncertainty table
 
DC current meters: intermediate values. Multimeter, 1.00E-04 A to 2 A
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µA/A: 20
Direct calibration
Approved on 10 November 2014
Internal NMI service identifier: KRISS/3.2.2
 
DC voltage sources: single values. Standard cell, solid state voltage standard, 1 V to 10 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in nV/V: 5.5 to 300
Null balance, difference measurement
Output voltage: 1 V, 1.018 V, 10 V
Approved on 10 November 2014
Internal NMI service identifier: KRISS/1.1.1
Uncertainty table
 
DC voltage sources: intermediate values. Multifunction calibrator, 10 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 2
Comparison with resistively divided voltage
Approved on 10 November 2014
Internal NMI service identifier: KRISS/1.1.3
 
DC voltage meters: intermediate values. Multimeter, DC voltmeter, 0.001 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µV/V: 1.5 to 700
Calibrator
Approved on 10 November 2014
Internal NMI service identifier: KRISS/1.2.2
Uncertainty table
 
DC voltage ratios: up to 1100 V. Resistive divider, 0.01 to 1
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 0.2
Potentiometry
Maximum input voltage: 1 kV
Approved on 10 November 2014
Internal NMI service identifier: KRISS/1.3.1
 
DC resistance standards and sources: low values. Fixed resistor, 1.00E-04 to 1
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 0.08 to 10
DCC bridge
Temperature: 25 °C
Power: 0.1 W
Approved on 10 November 2014
Internal NMI service identifier: KRISS/2.1.1
Uncertainty table
 
DC resistance standards and sources: intermediate values. Fixed resistor, 10 to 1.00E+06
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 0.1 to 1
DCC bridge
Temperature: 25 °C
Approved on 10 November 2014
Internal NMI service identifier: KRISS/2.1.2
Uncertainty table