Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (16)
PHYSICS >
DC voltage, current, and resistance (16)
DC resistance standards and sources: low values (2)
DC resistance standards and sources: intermediate values (2)
DC resistance standards and sources: high values (2)
DC voltage sources: single values (1)
DC voltage meters: intermediate values (1)
DC resistance meters: low values (1)
DC resistance meters: intermediate values (1)
DC current sources: intermediate values (1)
DC current meters: intermediate values (1)
DC current sources: low values (1)
DC current meters: low values (1)
DC voltage sources: low value ranges (1)
GEOGRAPHIC LOCATION
EURAMET (16)
Croatia (16)
Result of the search
Your query 'Croatia' produced 16 results New search

 
Croatia, FER-PEL (FER - Primary Electromagnetic Laboratory)
Complete CMCs in Electricity and Magnetism for Croatia (.PDF file)
DC voltage sources: low value ranges. DC voltage source, multifunction calibrator, 0 V to 10 V
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in µV: 0.2 to 70
Measurement with nanovoltmeter, DMM or resistive divider
Approved on 06 August 2013
Internal NMI service identifier: 1.5
Uncertainty table
 
DC resistance meters: low values. Ohmmeter, multimeter, 0.001 to 1
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 12 to 1
Reference and working resistance standards
Resistance: 1 mohm, 10 mohm, 100 mohm, 1 ohm
Approved on 06 August 2013
Internal NMI service identifier: 2.7
 
DC resistance meters: intermediate values. Ohmmeter, multimeter, 10 to 1E+08
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 1 to 12
Reference and working resistance standards
Resistance: 1 ohm, 10 ohm, 100 ohm, 1 kohm, 10 kohm, 100 kohm, 1 Mohm, 10 Mohm, 100 Mohm
Approved on 06 August 2013
Internal NMI service identifier: 2.8
 
DC current sources: low values. Current generator, multifunction calibrator, 0.01 µA to 100 µA
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µA/A: 32 to 4700
Measurement with DMM
Approved on 06 August 2013
Internal NMI service identifier: 3.1
Uncertainty table
 
DC current sources: intermediate values. Current generator, multifunction calibrator, 1E-04 A to 1 A
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µA/A: 29 to 250
Measurement with DMM
Approved on 06 August 2013
Internal NMI service identifier: 3.2
Uncertainty table
 
DC current meters: low values. Multimeter, 10 µA to 100 µA
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µA/A: 130 to 850
Multifunction calibrator
Approved on 06 August 2013
Internal NMI service identifier: 3.3
Uncertainty table
 
DC current meters: intermediate values. Multimeter, 1E-04 A to 2.2 A
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µA/A: 54 to 244
Multifunction calibrator
Approved on 06 August 2013
Internal NMI service identifier: 3.4
Uncertainty table
 
DC voltage sources: single values. Solid state voltage standard, 1 V to 10 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µV/V: 0.05 to 2.5
Difference measurement
Fixed voltage: 1 V, 1.018 V, 10 V
Approved on 06 August 2013
Internal NMI service identifier: 1.1
Uncertainty table
 
DC voltage sources: intermediate values. DC voltage source, calibrator, 10 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µV/V: 1 to 23
Measurement with DMM or resistive divider
Approved on 06 August 2013
Internal NMI service identifier: 1.11
Uncertainty table
 
DC voltage meters: intermediate values. DC voltmeter, multimeter, 0.001 V to 1100 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µV/V: 0.01 to 608
Josephson voltage standard, multifunction calibrator
Approved on 06 August 2013
Internal NMI service identifier: 1.12
Uncertainty table
 
DC resistance standards and sources: low values. Fixed resistor, 0.1 m to 1000 m
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 1 to 50
Comparison by means of DVM voltage ratio measurement method
Temperature: 23 °C
Approved on 06 August 2013
Internal NMI service identifier: 2.1
Uncertainty table
 
DC resistance standards and sources: low values. Fixed resistor, resistance box, 1 m to 1000 m
Relative expanded uncertainty (k = 2, level of confidence 95 %) in m/: 0.078 to 60
Measurement with DMM
Approved on 06 August 2013
Internal NMI service identifier: 2.2
Uncertainty table
 
DC resistance standards and sources: intermediate values. Fixed resistor, 0.001 k to 1000 k
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 1 to 5
Comparison by means of DVM voltage ratio measurement method
Temperature: 23 °C
Approved on 06 August 2013
Internal NMI service identifier: 2.3
Uncertainty table
 
DC resistance standards and sources: intermediate values. Fixed resistor, resistance box, 1 to 1E+06
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 13 to 78
Measurement with DMM
Approved on 06 August 2013
Internal NMI service identifier: 2.4
Uncertainty table
 
DC resistance standards and sources: high values. Fixed resistor, 1 M to 100 M
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µ/: 5 to 12
Comparison by means of DVM voltage ratio measurement method
Temperature: 23 °C
Approved on 06 August 2013
Internal NMI service identifier: 2.5
Uncertainty table
 
DC resistance standards and sources: high values. Fixed resistor, resistance box, 1 M to 1000 M
Relative expanded uncertainty (k = 2, level of confidence 95 %) in m/: 0.021 to 6
Measurement with DMM
Approved on 06 August 2013
Internal NMI service identifier: 2.6
Uncertainty table