Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs Chemistry (14)
CHEMICAL MATERIAL >
cosmetic cream (1)
cosmetic powder (1)
herb (1)
milk powder (1)
monoelemental aqueous solution (1)
CHEMICAL ANALYTE
lead (14)
GEOGRAPHIC LOCATION
APMP (14)
Korea, Republic of (14)
Result of the search
Your query 'kriss' produced 14 results New search

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Other materials for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95%) in %
Mass fraction in mg/kg Absolute expanded uncertainty
(k = 2, 95%) in %
cosmetic powder lead 1 to 100 1 to 5 24.55 to 28.69 1.2 to 1.6
Mechanism(s) for measurement service delivery: CRM 114-01-001, CRM 114-01-002
Uncertainty convention 1.
Approved on 20 January 2016.
Internal NMI service identifier: KRISS/114-01-001

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Food for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in mg/kg Absolute expanded uncertainty
(k = 2, 95 %) in mg/kg
milk powder lead 2 to 5 0.1 to 0.03
Mechanism(s) for measurement service delivery: Assignment of reference values for KOLAS proficiency test
Uncertainty convention 2.
Approved on 06 April 2007.
Internal NMI service identifier: KRISS/PT108-02A

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Other materials for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95%) in %
Mass fraction in mg/kg Absolute expanded uncertainty
(k = 2, 95%) in %
cosmetic cream lead 1 to 100 1 to 5 14.05 to 37.07 1.0 to 1.2
Mechanism(s) for measurement service delivery: CRM 114-01-003, CRM 114-01-004
Uncertainty convention 1.
Approved on 20 January 2016.
Internal NMI service identifier: KRISS/114-01-003C

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Advanced materials for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95%) in %
Mass fraction in mg/kg Absolute expanded uncertainty
(k = 2, 95%) in %
ABS lead 10 to 2000 1 to 5 25 to 1000 2 to 10
Mechanism(s) for measurement service delivery: CRM 113-01-011, CRM 113-01-012, CRM 113-01-013, CRM 113-01-014, CRM 113-01-015
Uncertainty convention 1.
Approved on 06 September 2012.
Internal NMI service identifier: KRISS/113-01-011G

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Inorganic solutions for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in g/kg Relative expanded uncertainty
(k = 2, 95%) in %
Mass fraction in g/kg Absolute expanded uncertainty
(k = 2, 95%) in %
monoelemental aqueous solution lead 0.9 to 1.1 0.1 to 0.5 0.9 to 1.1 0.1 to 0.5
Mechanism(s) for measurement service delivery: CRM 105-02-015
Approved on 12 March 2013.
Uncertainty convention 1.
Internal NMI service identifier: KRISS/105-02-PB2

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Advanced materials for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95%) in %
Mass fraction in mg/kg Absolute expanded uncertainty
(k = 2, 95%) in %
polypropylene (PP) lead 10 to 2000 1 to 5 15 to 1000 1 to 5
Mechanism(s) for measurement service delivery: CRM 113-01-001, CRM 113-01-002, CRM 113-01-003, CRM 113-01-004, CRM 113-01-005
Uncertainty convention 1.
Approved on 13 June 2013.
Internal NMI service identifier: KRISS/113-01-001D

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Food for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95 %) in %
Mass fraction in mg/kg Absolute expanded uncertainty
(k = 2, 95 %) in %
rice lead 0.1 to 100 1 to 5 0.12 1.6
Mechanism(s) for measurement service delivery: CRM 108-01-003, PT providing
Uncertainty convention 1.
Approved on 13 June 2013.
Internal NMI service identifier: KRISS/108-01-004C

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Food for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95 %) in %
Mass fraction in mg/kg Absolute expanded uncertainty
(k = 2, 95 %) in %
oyster lead 0.1 to 100 1 to 5 1.5 7.2
Mechanism(s) for measurement service delivery: CRM 108-04-001, PT providing
Uncertainty convention 1.
Approved on 13 June 2013.
Internal NMI service identifier: KRISS/108-04-001A

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Food for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95 %) in %
Mass fraction in mg/kg Absolute expanded uncertainty
(k = 2, 95 %) in %
water dropwort lead 0.1 to 100 1 to 5 1 15
Mechanism(s) for measurement service delivery: CRM 108-05-001, PT providing
Uncertainty convention 1.
Approved on 13 June 2013.
Internal NMI service identifier: KRISS/108-05-001A

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Food for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95 %) in %
Mass fraction in mg/kg Absolute expanded uncertainty
(k = 2, 95 %) in %
tomato paste lead 0.1 to 100 1 to 5 0.2 5
Mechanism(s) for measurement service delivery: CRM 108-05-005, PT providing
Uncertainty convention 1.
Approved on 13 June 2013.
Internal NMI service identifier: KRISS/108-05-005B

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Food for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95 %) in %
Mass fraction in mg/kg Absolute expanded uncertainty
(k = 2, 95 %) in %
ginseng lead 0.1 to 100 1 to 5 10.7 1
Mechanism(s) for measurement service delivery: CRM 108-10-006, PT providing
Uncertainty convention 1.
Approved on 13 June 2013.
Internal NMI service identifier: KRISS/108-10-006B

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Food for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95 %) in %
Mass fraction in mg/kg Absolute expanded uncertainty
(k = 2, 95 %) in %
mushroom lead 1 to 100 2 to 10 6.30 to 7.24 6.94
Mechanism(s) for measurement service delivery: CRM 108-10-011, PT providing
Uncertainty convention 1.
Approved on 13 June 2013.
Internal NMI service identifier: KRISS/CRM 108-10-011B

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Food for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95 %) in %
Mass fraction in mg/kg Absolute expanded uncertainty
(k = 2, 95 %) in %
tea leaf lead 0.05 to 100 1 to 5 0.05 to 0.1 4.6
Mechanism(s) for measurement service delivery: CRM 108-10-009, PT providing
Uncertainty convention 1.
Approved on 13 June 2013.
Internal NMI service identifier: KRISS/CRM 108-10-009D

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Food for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95 %) in %
Mass fraction in mg/kg Absolute expanded uncertainty
(k = 2, 95 %) in %
herb lead 0.5 to 100 1 to 5 3.547 to 3.651 1.4
Mechanism(s) for measurement service delivery: CRM 108-10-014, PT providing
Uncertainty convention 1.
Approved on 13 June 2013.
Internal NMI service identifier: KRISS/CRM 108-10-014B