Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs Ionizing Radiation (43)
IONIZING RADIATION >
Activity (43)
Am-241 (4)
Cs-137 (3)
Co-60 (3)
Co-57 (3)
Y-88 (3)
Ce-139 (3)
Cd-109 (3)
Sn-113 (3)
Cr-51 (2)
Sr-85 (2)
GEOGRAPHIC LOCATION
APMP (43)
Korea, Republic of (43)
Result of the search
Your query 'kriss' produced 43 results New search
1  2  3

 
Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Ionizing Radiation for Korea, Republic of (.PDF file)
Activity. Single nuclide, solid, 4.0E+04 Bq to 4.0E+05 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.2
HP Ge spectrometer
Na-22: point source smaller or equal to 7 mm in diameter
Reference standard: 4- absolute measurement
Source of traceability: KRISS
Approved on 14 February 2005
Internal NMI service identifier: APM-RAD-KRISS-2099
Activity. Single nuclide, solid, 4.0E+04 Bq to 4.0E+05 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.2
HP Ge spectrometer
Mn-54: point source smaller or equal to 7 mm in diameter
Reference standard: 4(e,X)- absolute measurement
Source of traceability: KRISS
Approved on 14 February 2005
Internal NMI service identifier: APM-RAD-KRISS-2100
Activity. Single nuclide, solid, 4.0E+04 Bq to 4.0E+05 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.2
HP Ge spectrometer
Co-57: point source smaller or equal to 7 mm in diameter
Reference standard: 4(e,X)- absolute measurement
Source of traceability: KRISS
Approved on 14 February 2005
Internal NMI service identifier: APM-RAD-KRISS-2101
Activity. Single nuclide, solid, 4.0E+04 Bq to 4.0E+05 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.2
HP Ge spectrometer
Co-60: point source smaller or equal to 7 mm in diameter
Reference standard: 4- absolute measurement
Source of traceability: KRISS
Approved on 14 February 2005
Internal NMI service identifier: APM-RAD-KRISS-2102
Activity. Single nuclide, solid, 4.0E+04 Bq to 4.0E+05 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.2
HP Ge spectrometer
Zn-65: point source smaller or equal to 7 mm in diameter
Reference standard: 4(e,X)- absolute measurement
Source of traceability: KRISS
Approved on 14 February 2005
Internal NMI service identifier: APM-RAD-KRISS-2103
Activity. Single nuclide, solid, 1.0E+05 Bq to 1.0E+06 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 2.8
HP Ge spectrometer
Se-75: point source smaller or equal to 7 mm in diameter
Reference standard: 4(e,X)- absolute measurement
Source of traceability: KRISS
Approved on 14 February 2005
Internal NMI service identifier: APM-RAD-KRISS-2104
Activity. Single nuclide, solid, 4.0E+04 Bq to 4.0E+05 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.2
HP Ge spectrometer
Y-88: point source smaller or equal to 7 mm in diameter
Reference standard: 4(e,X)- absolute measurement
Source of traceability: KRISS
Approved on 14 February 2005
Internal NMI service identifier: APM-RAD-KRISS-2105
Activity. Single nuclide, solid, 1.0E+05 Bq to 1.0E+07 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.2
HP Ge spectrometer
Cd-109: point source smaller or equal to 7 mm in diameter
Reference standard: 4(e,X)- absolute measurement
Source of traceability: KRISS
Approved on 14 February 2005
Internal NMI service identifier: APM-RAD-KRISS-2106
Activity. Single nuclide, solid, 4.0E+04 Bq to 4.0E+05 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.2
HP Ge spectrometer
Ag-110m: point source smaller or equal to 7 mm in diameter
Reference standard: 4- absolute measurement
Source of traceability: KRISS
Approved on 14 February 2005
Internal NMI service identifier: APM-RAD-KRISS-2107
Activity. Single nuclide, solid, 4.0E+04 Bq to 4.0E+05 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.4
HP Ge spectrometer
Sn-113: point source smaller or equal to 7 mm in diameter
Reference standard: 4(e,X)- absolute measurement
Source of traceability: KRISS
Approved on 14 February 2005
Internal NMI service identifier: APM-RAD-KRISS-2108
Activity. Single nuclide, solid, 4.0E+04 Bq to 4.0E+06 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.4
HP Ge spectrometer
Ba-133: point source smaller or equal to 7 mm in diameter
Reference standard: 4(e,X)- absolute measurement
Source of traceability: KRISS
Approved on 14 February 2005
Internal NMI service identifier: APM-RAD-KRISS-2109
Activity. Single nuclide, solid, 4.0E+04 Bq to 4.0E+05 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.4
HP Ge spectrometer
Cs-134: point source smaller or equal to 7 mm in diameter
Reference standard: 4- absolute measurement
Source of traceability: KRISS
Approved on 14 February 2005
Internal NMI service identifier: APM-RAD-KRISS-2110
Activity. Single nuclide, solid, 4.0E+04 Bq to 4.0E+05 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.6
HP Ge spectrometer
Cs-137: point source smaller or equal to 7 mm in diameter
Reference standard: 4- absolute measurement
Source of traceability: KRISS
Approved on 14 February 2005
Internal NMI service identifier: APM-RAD-KRISS-2111
Activity. Single nuclide, solid, 4.0E+04 Bq to 4.0E+05 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.2
HP Ge spectrometer
Ce-139: point source smaller or equal to 7 mm in diameter
Reference standard: 4(e,X)- absolute measurement
Source of traceability: KRISS
Approved on 14 February 2005
Internal NMI service identifier: APM-RAD-KRISS-2112
Activity. Single nuclide, solid, 4.0E+04 Bq to 4.0E+06 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.4
HP Ge spectrometer
Eu-152: point source smaller or equal to 7 mm in diameter
Reference standard: 4- absolute measurement
Source of traceability: KRISS
Approved on 14 February 2005
Internal NMI service identifier: APM-RAD-KRISS-2113
Activity. Single nuclide, solid, 4.0E+04 Bq to 4.0E+05 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.2
HP Ge spectrometer
Ho-166m: point source smaller or equal to 7 mm in diameter
Reference standard: 4- absolute measurement
Source of traceability: KRISS
Approved on 14 February 2005
Internal NMI service identifier: APM-RAD-KRISS-2114
Activity. Single nuclide, solid, 4.0E+04 Bq to 4.0E+05 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.4
HP Ge spectrometer
Bi-207: point source smaller or equal to 7 mm in diameter
Reference standard: -ray spectrometry with defined solid angle, standard set of weights
Source of traceability: KRISS
Approved on 01 June 2011
Internal NMI service identifier: APM-RAD-KRISS-2115
Activity. Single nuclide, solid, 4.0E+04 Bq to 4.0E+06 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.2
HP Ge spectrometer
Am-241: point source smaller or equal to 7 mm in diameter
Reference standard: 4- absolute measurement
Source of traceability: KRISS
Approved on 14 February 2005
Internal NMI service identifier: APM-RAD-KRISS-2116
Activity. Multiple nuclide, solid, 4.0E+02 Bq to 4.0E+06 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 2
HP Ge spectrometer
Cr-51: Gamma emitting point source, smaller or equal to 7 mm in diameter
Reference standard: Primary standard sources
Source of traceability: KRISS
Approved on 14 February 2005
Internal NMI service identifier: APM-RAD-KRISS-2158
Activity. Multiple nuclide, solid, 4.0E+02 Bq to 4.0E+06 Bq
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 2
HP Ge spectrometer
Co-57: Gamma emitting point source, smaller or equal to 7 mm in diameter
Reference standard: Primary standard sources
Source of traceability: KRISS
Approved on 14 February 2005
Internal NMI service identifier: APM-RAD-KRISS-2158