Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs Ionizing Radiation
CMCs General Physics (3)
PHYSICS
Radio frequency measurements
AC voltage, current, and power (3)
AC power and energy: single phase (frequency > 400 Hz), active power (3)
CHEMICAL ANALYTE
ethane
GEOGRAPHIC LOCATION
EURAMET (3)
United Kingdom (3)
Result of the search
Your query 'United Kingdom' produced 3 results New search

 
United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Electricity and Magnetism for United Kingdom (.PDF file)
AC power and energy: single phase (frequency > 400 Hz), active power. Wattmeter, 0.03 W to 3000 W
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µW (VA)-1: 200
3 voltmeter method
Frequency: 400 Hz to 30 kHz
Voltage: 0.3 V to 300 V
Current: 0.1 A to 10 A
Power factor: 1
Approved on 06 August 2013
Internal NMI service identifier: 286,3
 
AC power and energy: single phase (frequency > 400 Hz), active power. Wattmeter, 0 W to 3000 W
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µW (VA)-1: 500
3 voltmeter method
Frequency: 400 Hz to 30 kHz
Voltage: 0.3 V to 300 V
Current: 0.1 A to 10 A
Power factor: 1 to 0, inductive or capacitive
Approved on 06 August 2013
Internal NMI service identifier: 286,4
 
AC power and energy: single phase (frequency > 400 Hz), active power. Wattmeter, 0 W to 3000 W
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µW (VA)-1: 1200
3 voltmeter method
Frequency: 30 kHz to 100 kHz
Voltage: 0.3 V to 300 V
Current: 0.1 A to 10 A
Power factor: 1 to 0, inductive or capacitive
Approved on 06 August 2013
Internal NMI service identifier: 286,5