Result of the search
Your query 'kriss' produced 19 results New search

 
Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Acoustics, Ultrasound, Vibration for Korea, Republic of (.PDF file)
Charge sensitivity (phase shift). Angular accelerometer, 0 ° to 360 °
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in °: 0.5
ISO 16063-15:2006 (interferometry)
Frequency: 1 Hz to 800 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C64312
 
Voltage sensitivity (phase shift). Angular acceleration measuring chain, 0 ° to 360 °
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in °: 0.5
ISO 16063-15:2006 (interferometry)
Frequency: 1 Hz to 800 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C64412
 
Acceleration (modulus). Acceleration measuring instrument (with accelerometer), 10 m/s2 to 100 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.5
ISO 16063-11:1999 (interferometry)
Frequency: 20 Hz to 250 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C63111
 
Acceleration (modulus). Acceleration measuring instrument (with accelerometer), 10 m/s2 to 200 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1
ISO 16063-11:1999 (interferometry)
Frequency: > 250 Hz to 5 kHz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C63111
 
Acceleration (modulus). Acceleration calibrator, 10 m/s2 to 100 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 2
ISO 16063-21:2003 (comparison)
Frequency: 80 Hz or 160 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C63211
 
Charge sensitivity (modulus). Accelerometer. Measurand unit, C/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1
ISO 16063-11:1999 (interferometry)
Frequency: 20 Hz to 5 kHz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C63311
 
Charge sensitivity (modulus). Accelerometer. Measurand unit, C/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 2
ISO 16063-21:2003 (comparison)
Frequency: 20 Hz to 5 kHz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C63311
 
Voltage sensitivity (modulus). Acceleration measuring chain. Measurand unit, V/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.5
ISO 16063-11:1999 (interferometry)
Frequency: 20 Hz to 250 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C63411
 
Voltage sensitivity (modulus). Acceleration measuring chain. Measurand unit, V/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1
ISO 16063-11:1999 (interferometry)
Frequency: 315 Hz to 5 kHz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C63411
 
Voltage sensitivity (modulus). Acceleration measuring chain. Measurand unit, V/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 2
ISO 16063-21:2003 (comparison)
Frequency: 20 Hz to 5 kHz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C63411
 
Angular acceleration (modulus). Angular acceleration measuring instrument (with angular accelerometer), 10 rad/s2 to 100 rad/s2
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.5
ISO 16063-15:2006 (interferometry)
Frequency: 1 Hz to 8 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C64111
 
Angular acceleration (modulus). Angular acceleration measuring instrument (with angular accelerometer), 50 rad/s2 to 200 rad/s2
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.3
ISO 16063-15:2006 (interferometry)
Frequency: 10 Hz to 160 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C64111
 
Angular acceleration (modulus). Angular acceleration measuring instrument (with angular accelerometer), 50 rad/s2 to 200 rad/s2
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.8
ISO 16063-15:2006 (interferometry)
Frequency: 200 Hz to 800 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C64111
 
Charge sensitivity (modulus). Angular accelerometer. Measurand unit, C/(rad/s2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.5
ISO 16063-15:2006 (interferometry)
Frequency: 1 Hz to 8 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C64311
 
Charge sensitivity (modulus). Angular accelerometer. Measurand unit, C/(rad/s2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.3
ISO 16063-15:2006 (interferometry)
Frequency: 10 Hz to 160 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C64311
 
Charge sensitivity (modulus). Angular accelerometer. Measurand unit, C/(rad/s2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.8
ISO 16063-15:2006 (interferometry)
Frequency: 200 Hz to 800 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C64311
 
Voltage sensitivity (modulus). Angular acceleration measuring chain. Measurand unit, V/(rad/s2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.5
ISO 16063-15:2006 (interferometry)
Frequency: 1 Hz to 8 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C64411
 
Voltage sensitivity (modulus). Angular acceleration measuring chain. Measurand unit, V/(rad/s2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.3
ISO 16063-15 2006 (interferometry)
Frequency: 10 Hz to 160 Hz
Approved on 26 April 2017
Internal NMI service identifier: KRISS/C64411
 
Voltage sensitivity (modulus). Angular acceleration measuring chain. Measurand unit, V/(rad/s2)
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.8
ISO 16063-15:2006 (interferometry)
Frequency: 200 Hz to 800 Hz
Approved on 26 April 2017