Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (13)
PHYSICS
Frequency (13)
Frequency (13)
GEOGRAPHIC LOCATION
APMP (13)
Korea, Republic of (13)
Result of the search
Your query 'kriss' produced 13 results New search

 
Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Time and Frequency for Korea, Republic of (.PDF file)
Frequency. Local frequency standard, 5 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 1E-14
Dual mixer time difference measurement
Measurement time: 1 d
Amplitude: > 0.5 V (50 )
DUT effects excluded
Approved on 13 February 2013
Internal NMI service identifier: C301021
 
Frequency. Local frequency standard, 1 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 1E-13
Direct frequency measurement
Gate time: 1000 s
Number of measurements: 100
Amplitude: > 0.5 V (50 )
DUT effects excluded
Approved on 13 February 2013
Internal NMI service identifier: C301021
 
Frequency. Local frequency standard, 5 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 1E-13
Direct frequency measurement
Gate time: 1000 s
Number of measurements: 100
Amplitude: > 0.5 V (50 )
DUT effects excluded
Approved on 13 February 2013
Internal NMI service identifier: C301021
 
Frequency. Local frequency standard, 10 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 1E-13
Direct frequency measurement
Gate time: 1000 s
Number of measurements: 100
Amplitude: > 0.5 V (50 )
DUT effects excluded
Approved on 13 February 2013
Internal NMI service identifier: C301021
 
Frequency. Remote frequency standard, 5 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 2E-13
GPS common-view time transfer
Measurement time: 2 d
Baseline: < 1000 km
DUT effects excluded
Approved on 13 February 2013
Internal NMI service identifier: C301021
 
Frequency. Remote frequency standard, 10 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 2E-13
GPS common-view time transfer
Measurement time: 2 d
Baseline: < 1000 km
DUT effects excluded
Approved on 13 February 2013
Internal NMI service identifier: C301021
 
Frequency. General frequency source, 0.1 Hz to 100 Hz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 2E-11
Direct frequency measurement
Gate time: 100 s
Number of measurements: 100
Amplitude: > 0.5 V (50 )
DUT effects excluded
Approved on 13 February 2013
Internal NMI service identifier: C301022
 
Frequency. General frequency source, 1E-04 MHz to 100 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 1E-12
Direct frequency measurement
Gate time: 100 s
Number of measurements: 100
Amplitude: > 0.5 V (50 )
DUT effects excluded
Approved on 13 February 2013
Internal NMI service identifier: C301022
 
Frequency. Frequency counter, 1 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 1E-13
Direct frequency measurement
Gate time: 1000 s
Number of measurements: 100
Amplitude: > 0.5 V (50 )
DUT effects excluded
Approved on 13 February 2013
Internal NMI service identifier: C301041
 
Frequency. Frequency counter, 5 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 1E-13
Direct frequency measurement
Gate time: 1000 s
Number of measurements: 100
Amplitude: > 0.5 V (50 )
DUT effects excluded
Approved on 13 February 2013
Internal NMI service identifier: C301041
 
Frequency. Frequency counter, 10 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 1E-13
Direct frequency measurement
Gate time: 1000 s
Number of measurements: 100
Amplitude: > 0.5 V (50 )
DUT effects excluded
Approved on 13 February 2013
Internal NMI service identifier: C301041
 
Frequency. Frequency meter, 0.1 Hz to 100 Hz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 1E-11
Direct frequency measurement
Gate time: 100 s
Number of measurements: 100
Amplitude: > 0.5 V (50 )
DUT effects excluded
Approved on 13 February 2013
Internal NMI service identifier: C301042
 
Frequency. Frequency meter, 1E-04 MHz to 20 MHz
Relative expanded uncertainty (k = 2, level of confidence 95 %) in Hz/Hz: 1E-12
Direct frequency measurement
Gate time: 100 s
Number of measurements: 100
Amplitude: > 0.5 V (50 )
DUT effects excluded
Approved on 13 February 2013
Internal NMI service identifier: C301042