Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (12)
PHYSICS
Electric and magnetic fields (12)
Magnetic fields below 50 kHz: DC magnetic flux density and applied magnetic field strength (4)
Electromagnetic fields above 50 kHz: electric field strength (2)
Magnetic fields below 50 kHz: DC shielding factor (ratio of DC magnetic flux density) (1)
Magnetic field below 50 kHz: magnetic flux (1)
Magnetic fields below 50 kHz: AC magnetic flux density and applied magnetic field strength (1)
Magnetic fields below 50 kHz: turn area (ratio of magnetic flux and magnetic flux density) (1)
Electromagnetic fields above 50 kHz: magnetic field strength (1)
Electromagnetic fields above 50 kHz: power flux density (1)
GEOGRAPHIC LOCATION
APMP (12)
Korea, Republic of (12)
Result of the search
Your query 'kriss' produced 12 results New search

 
Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Electricity and Magnetism for Korea, Republic of (.PDF file)
Magnetic fields below 50 kHz: DC magnetic flux density and applied magnetic field strength. Magnetometer, solenoid coil, Helmholtz coil, 0.05 mT to 1.2 mT
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in nT: 4
Helium-4 Atomic Magnetic Resonance (AMR), Helmholtz coil
Resonance frequency: 1 MHz to 50 MHz
Approved on 10 November 2014
Internal NMI service identifier: KRISS/10.2.2c
 
Magnetic fields below 50 kHz: DC shielding factor (ratio of DC magnetic flux density). Magnetic shell, shielding factor in DC field, 0 dB to 80 dB
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 10
Helium-4 AMR, Cesium AMR, fluxgate magnetometer, non-magnetic facilities
Maximum field: 1 mT
Shell size: less than a sphere of 15 cm in diameter
Approved on 10 November 2014
Internal NMI service identifier: KRISS/10.2.4
 
Magnetic field below 50 kHz: magnetic flux. Fluxmeter, 0.0001 Wb to 10 Wb
Relative expanded uncertainty (k = 2, level of confidence 95 %) in mWb/Wb: 0.7
Fluxmeter, voltage-time integral
Sampling frequency: 100 Hz
Approved on 10 November 2014
Internal NMI service identifier: KRISS/10.2.1
 
Magnetic fields below 50 kHz: DC magnetic flux density and applied magnetic field strength. Magnetometer, solenoid coil, Helmholtz coil, electromagnet, 0.04 T to 2.5 T
Relative expanded uncertainty (k = 2, level of confidence 95%) in µT/T: 5
Nuclear Magnetic Resonance (NMR), electromagnet
Resonance frequency: 1 MHz to 150 MHz
Approved on 10 November 2014
Internal NMI service identifier: KRISS/10.2.2a
 
Magnetic fields below 50 kHz: DC magnetic flux density and applied magnetic field strength. Magnetometer, solenoid coil, Helmholtz coil, 1 mT to 40 mT
Relative expanded uncertainty (k = 2, level of confidence 95 %) in mT/T: 0.25
Helium-4 Atomic Magnetic Resonance (AMR), Helmholtz coil
Resonance frequency: 3 MHz to 300 MHz
Approved on 10 November 2014
Internal NMI service identifier: KRISS/10.2.2b
 
Magnetic fields below 50 kHz: DC magnetic flux density and applied magnetic field strength. Reference magnet with air gap, 0.001 T to 0.5 T
Relative expanded uncertainty (k = 2, level of confidence 95 %) in mT/T: 2
Hall magnetometer, NMR, AMR
Minimum air gap size: 2 mm
Approved on 10 November 2014
Internal NMI service identifier: KRISS/10.2.2d
 
Magnetic fields below 50 kHz: AC magnetic flux density and applied magnetic field strength. Field generator, AC magnetometer, 0.001 mT to 1 mT
Relative expanded uncertainty (k = 2, level of confidence 95 %) in mT/T: 2 to 5
Direct comparison with search coil
Frequency: 0.1 kHz to 20 kHz
Approved on 10 November 2014
Internal NMI service identifier: KRISS/10.2.3
Uncertainty table
 
Magnetic fields below 50 kHz: turn area (ratio of magnetic flux and magnetic flux density). Sensing coil, area turns, 0.005 m2 to 0.3 m2
Relative expanded uncertainty (k = 2, level of confidence 95%) in cm2/m2: 50
Fluxmeter, NMR
Coil size: smaller than a square of side length 10 cm
Approved on 10 November 2014
Internal NMI service identifier: KRISS/10.2.6
 
Electromagnetic fields above 50 kHz: electric field strength. Field probe, 1 V/m to 600 V/m
Relative expanded uncertainty (k = 2, level of confidence 95 %) in dB: 1
TEM cell
Frequency: 10 kHz to 300 MHz
Approved on 10 November 2014
Internal NMI service identifier: KRISS/10.3.1a
Uncertainty table
 
Electromagnetic fields above 50 kHz: electric field strength. Field probe, 1 V/m to 100 V/m
Relative expanded uncertainty (k = 2, level of confidence 95 %) in dB: 1
Anechoic chamber
Frequency: 0.2 GHz to 18 GHz
Approved on 10 November 2014
Internal NMI service identifier: KRISS/10.3.1b
Uncertainty table
 
Electromagnetic fields above 50 kHz: magnetic field strength. Field probe, 0.003 A/m to 1.6 A/m
Relative expanded uncertainty (k = 2, level of confidence 95%) in dB: 1.5
TEM cell
Frequency: 10 kHz to 300 MHz
Approved on 10 November 2014
Internal NMI service identifier: KRISS/10.3.2
Uncertainty table
 
Electromagnetic fields above 50 kHz: power flux density. Field probe, 0.003 W/m2 to 26.5 W/m2
Relative expanded uncertainty (k = 2, level of confidence 95 %) in dB: 1
Anechoic chamber
Frequency: 0.2 GHz to 18 GHz
Approved on 10 November 2014
Internal NMI service identifier: KRISS/10.3.3
Uncertainty table