Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (3)
PHYSICS
AC voltage, current, and power (3)
AC voltage ratio: imaginary component (3)
IONIZING RADIATION
Ambient dose equivalent rate
Emission anisotropy
GEOGRAPHIC LOCATION
EURAMET (3)
United Kingdom (3)
Result of the search
Your query 'United Kingdom' produced 3 results New search

 
United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Electricity and Magnetism for United Kingdom (.PDF file)
AC voltage ratio: imaginary component. Inductive voltage divider, -0.001 to 0.001
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 6.9E-08 to 2.1E-07
Comparison with reference divider
Frequency: 40 Hz to 5 kHz
Maximum RMS voltage: 4 V to 30 V
Approved on 06 August 2013
Internal NMI service identifier: 219
Uncertainty table
 
AC voltage ratio: imaginary component. Inductive voltage divider, -0.001 to 0.001
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 2.1E-07 to 1.6E-05
Comparison with reference divider
Frequency: 5 kHz to 120 kHz
Maximum RMS voltage: 30 V
Approved on 07 February 2019
Internal NMI service identifier: 231
Uncertainty table
 
AC voltage ratio: imaginary component. Voltage transformer, -2.4 mrad to 2.4 mrad
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in µrad: 30
IVD and mutual inductance bridge
Frequency: 50 Hz
Approved on 06 August 2013
Internal NMI service identifier: 241