Your query 'United Kingdom' produced 1 result New search

 
United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Electricity and Magnetism for United Kingdom (.PDF file)
Scattering parameters: transmission coefficient (Sij) on coaxials, real and imaginary. Passive device, two port device, -1 to 1
Absolute expanded uncertainty (k = 2.5, level of confidence 95 %): 0.00004 to 0.0010
Network analyser
Frequency range: 10 MHz to 67 GHz
Connector type: 7-16, GR900, GPC-7, Type-N, 3.5 mm, 2.92 mm, 2.4 mm, 1.85 mm
Impedance: 50
Uncertainty for low loss devices is dominated by repeatability and device performance. The value estimated here is based upon the repeatability of a through connection towards the low end of the frequency band. The coverage factors in the uncertainty tab
Internal NMI service identifier: 479
Uncertainty table