Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (6)
PHYSICS
Materials (6)
Dielectric properties: loss tangent (6)
Electrical conductivity: metallic materials
CHEMICAL ANALYTE
ethane
GEOGRAPHIC LOCATION
EURAMET (6)
United Kingdom (6)
Result of the search
Your query 'United Kingdom' produced 6 results New search

 
United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Electricity and Magnetism for United Kingdom (.PDF file)
Dielectric properties: loss tangent. Solid material, tan, 0.00002 to 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): Q[0.02 tan, 0.00002]
Three terminal admittance cell and bridge
Frequency: 1 kHz to 3 MHz
Temperature: 20 °C to 25 °C
Approved on 06 August 2013
Internal NMI service identifier: 518
 
Dielectric properties: loss tangent. Solid material, tan, 0.01 to 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): Q[0.02 tan, 0.005]
14 mm coaxial line and network analyser
Frequency: 50 MHz to 6 GHz
Temperature: 20 °C to 25 °C
Approved on 06 August 2013
Internal NMI service identifier: 519
 
Dielectric properties: loss tangent. Solid material, tan, 0.01 to 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): Q[0.02 tan, 0.005]
7 mm coaxial line and network analyser
Frequency: 100 MHz to 18 GHz
Temperature: 20 °C to 25 °C
Approved on 06 August 2013
Internal NMI service identifier: 520
 
Dielectric properties: loss tangent. Solid material, tan, 0.01 to 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): Q[0.02 tan, 0.005]
14 mm coaxial line and network analyser
Frequency: 50 MHz to 6 GHz
Temperature: 20 °C to 25 °C
Approved on 06 August 2013
Internal NMI service identifier: 521
 
Dielectric properties: loss tangent. Solid material, tan, 0.00002 to 0.05
Absolute expanded uncertainty (k = 2, level of confidence 95 %): Q[0.05 tan, 0.00002]
Two terminal resonant cell, Q-meter or bridge
Frequency: 1 MHz to 70 MHz
Temperature: 20 °C to 25 °C
Approved on 06 August 2013
Internal NMI service identifier: 523
 
Dielectric properties: loss tangent. Solid material, tan, 0.00001 to 0.002
Absolute expanded uncertainty (k = 2, level of confidence 95 %): Q[0.03 tan, 0.00001]
Open resonator and network analyser
Frequency: 36 GHz and 72 GHz
Temperature: 20 °C to 25 °C
Approved on 06 August 2013
Internal NMI service identifier: 524