Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics
CMCs Ionizing Radiation (7)
IONIZING RADIATION
Emission rate
Personal dose equivalent rate
Absorbed dose to water (7)
CHEMICAL ANALYTE
ethane
GEOGRAPHIC LOCATION
EURAMET (7)
Denmark (7)
Result of the search
Your query 'United Kingdom' produced 7 results New search

 
Denmark, DTU (Technical University of Denmark)
Complete CMCs in Ionizing Radiation for Denmark (.PDF file)
Absorbed dose to water. Passive dosimeter (Alanine, Radiochromic film, Perspex), 0.2 kGy to 100 kGy
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 2.9
Irradiation in calibrated photon field
Photons: Irradiation in reference Co-60 gamma ray field (Gamma cell)
Reference standard: Photon beam graphite calorimeter at National Physical Laboratory
Source of traceability: National Physical Laboratory, United Kingdom
Approved on 20 April 2015
Internal NMI service identifier: EUR-RAD-DTU-1001
Absorbed dose to water. Alanine pellet / EPR dosimeter, 0.2 kGy to 100 kGy
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 3.2
Irradiation of transfer dosimeters in phantoms
Photons: Irradiation in customer's Co-60 gamma field
Reference standard: Calibrated Co-60 gamma field
Source of traceability: National Physical Laboratory, United Kingdom
Approved on 20 April 2015
Internal NMI service identifier: EUR-RAD-DTU-1002
Absorbed dose to water. Graphite calorimeter, 1.5 kGy to 15 kGy
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 4.1
Irradiation in calibrated electron field
Electrons: Irradiation in customer's electron field (6 to 10 MeV)
Reference standard: Calibrated Co-60 gamma field
Source of traceability: National Physical Laboratory, United Kingdom
Approved on 20 April 2015
Internal NMI service identifier: EUR-RAD-DTU-1003
Absorbed dose to water. Polystyrene calorimeter, 3 kGy to 10 kGy
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 4.0
Irradiation in calibrated electron field
Electrons: Irradiation in customer's electron field (1.5 to 10 MeV)
Reference standard: Calibrated Co-60 gamma field
Source of traceability: National Physical Laboratory, United Kingdom
Approved on 20 April 2015
Internal NMI service identifier: EUR-RAD-DTU-1004
Absorbed dose to water. Alanine pellet / EPR dosimeter, 0.2 kGy to 100 kGy
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 3.5
Irradiation of transfer dosimeters in phantoms
Electrons: Irradiation in customer's electron field (1.5 to 10 MeV)
Reference standard: Calibrated Co-60 gamma field
Source of traceability: National Physical Laboratory, United Kingdom
Approved on 20 April 2015
Internal NMI service identifier: EUR-RAD-DTU-1007
Absorbed dose to water. Alanine film / EPR dosimeter, 1 kGy to 120 kGy
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 3.6
Irradiation of transfer dosimeters in phantoms
Electrons: Irradiation in customer's electron field (0.1 to 10 MeV)
Reference standard: Calibrated Co-60 gamma field
Source of traceability: National Physical Laboratory, United Kingdom
Approved on 20 April 2015
Internal NMI service identifier: EUR-RAD-DTU-1008
Absorbed dose to water. Risø B3 film dosimeter, 10 kGy to 100 kGy
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 8.2
Irradiation in calibrated electron field
Electrons: Irradiation in customer's electron field (0.1 to 10 MeV)
Reference standard: Calibrated Co-60 gamma field
Source of traceability: National Physical Laboratory, United Kingdom
Approved on 20 April 2015
Internal NMI service identifier: EUR-RAD-DTU-1009