United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
synthetic air carbonyl sulfide 1 to 10 2 1 to 10 2
Mechanism(s) for measurement service delivery: SGS and calibration
Internal NMI service identifier: NPL/36

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
synthetic air ethanol 100 to 200 1.5 100 to 200 1.5
Mechanism(s) for measurement service delivery: PRGM, SGS and calibration
Approved on 30 June 2017.
Internal NMI service identifier: NPL/56 rev
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
synthetic air methanol 10 to 100 5 to 2 10 to 100 5 to 2
Mechanism(s) for measurement service delivery: PRGM, SGS and calibration
Internal NMI service identifier: NPL/56 rev
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
synthetic air acetone 10 to 100 5 10 to 100 5
Mechanism(s) for measurement service delivery: PRGM, SGS and calibration
Internal NMI service identifier: NPL/56 rev
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
synthetic air methylethyl ketone 100 to 1000 5 100 to 1000 5
Mechanism(s) for measurement service delivery: PRGM, SGS and calibration
Internal NMI service identifier: NPL/56 rev
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
synthetic air toluene 10 to 100 5 10 to 100 5
Mechanism(s) for measurement service delivery: PRGM, SGS and calibration
Internal NMI service identifier: NPL/56 rev
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
synthetic air methane 1 to 10 3 1 to 10 3
Mechanism(s) for measurement service delivery: PRGM, SGS and calibration
Internal NMI service identifier: NPL/57
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
synthetic air ethane 1 to 10 3 1 to 10 3
Mechanism(s) for measurement service delivery: PRGM, SGS and calibration
Internal NMI service identifier: NPL/57
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
synthetic air toluene 0.1 to 1 3 0.1 to 1 3
Mechanism(s) for measurement service delivery: PRGM, SGS and calibration
Internal NMI service identifier: NPL/57
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
synthetic air benzene 0.1 to 1 3 0.1 to 1 3
Mechanism(s) for measurement service delivery: PRGM, SGS and calibration
Internal NMI service identifier: NPL/57
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
synthetic air dichloromethane 0.1 to 1 3 0.1 to 1 3
Mechanism(s) for measurement service delivery: PRGM, SGS and calibration
Internal NMI service identifier: NPL/57
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
synthetic air carbon monoxide 10 to 100 3 10 to 100 3
Mechanism(s) for measurement service delivery: PRGM, SGS and calibration
Internal NMI service identifier: NPL/57
This displays only one part of a multi-component CMC.

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
synthetic air nitrogen dioxide 10 to 100 1 to 0.6 10 to 100 0.4 to 0.3
Mechanism(s) for measurement service delivery: PRGM and calibration
Approved on 06 September 2012.
Internal NMI service identifier: NPL/16c

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
synthetic air nitrogen dioxide 100 to 1000 0.6 to 0.2 100 to 1000 0.3 to 0.2
Mechanism(s) for measurement service delivery: PRGM and calibration
Approved on 06 September 2012.
Internal NMI service identifier: NPL/16d

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
synthetic air nitrogen dioxide 1 to 10 3 to 1 1 to 10 3 to 1
Mechanism(s) for measurement service delivery: SGS and calibration
Approved on 13 June 2013.
Internal NMI service identifier: NPL/76

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in nmol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in nmol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
synthetic air nitrogen dioxide 100 to 1000 3 100 to 1000 3
Mechanism(s) for measurement service delivery: SGS and calibration
Approved on 13 June 2013.
Internal NMI service identifier: NPL/77

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
synthetic air ethanol 50 to 500 0.25 to 0.15 50 to 500 0.35 to 0.25
Mechanism(s) for measurement service delivery: PRGM and calibration
Approved on 08 July 2015.
Internal NMI service identifier: NPL/79

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
synthetic air propane 1 to 10 1 to 0.2 1 to 10 1 to 0.2
Mechanism(s) for measurement service delivery: PRGM and calibration
Approved on 08 July 2015.
Internal NMI service identifier: NPL/107

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in nmol/mol Absolute expanded uncertainty
(k = 2, 95 %) in nmol/mol
synthetic air methane 3.6 to 1000 3.6
Mechanism(s) for measurement service delivery: Calibration
Approved on 08 July 2015.
Internal NMI service identifier: NPL/96

United Kingdom, NPL (National Physical Laboratory)
Complete CMCs in Chemistry for Gases for United Kingdom (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in nmol/mol
synthetic air methane 1 to 1.7 3.6
Mechanism(s) for measurement service delivery: Calibration
Approved on 08 July 2015.
Internal NMI service identifier: NPL/97