Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
METROLOGY AREA
Electricity and Magnetism (9)
Ionizing Radiation (9)
Amount of Substance (8)
Thermometry (5)
Length (4)
Mass (4)
Acoustics, Ultrasound, and Vibration (1)
TYPE
Supplementary comparisons (40)
STATUS
Approved (21)
Measurements in progress (6)
Report in progress, draft B (4)
Abandoned (3)
Planned (2)
Protocol complete (2)
Report in progress, draft A (2)
ORGANISATIONS
APMP (33)
CCRI (4)
SIM (2)
EURAMET (formerly EUROMET) (1)
Result of the search
Your query 'India' produced 40 results New search
1  2

  APMP.EM- S2 Comparison of AC/DC voltage transfer standards
1996 - 1998
Comparison type, Field   Supplementary comparison in Electricity and Magnetism, AC Voltage, Current, Power, and AC/DC Transfer
Parameter(s)   Voltage: 10 V, 100 V and 1000 V
Frequency: 0.01 kHz to 1 MHz
Status   Approved
  APMP.EM- S1 Comparison of capacitors
1992 - 1994
Comparison type, Field   Supplementary comparison in Electricity and Magnetism, Capacitance
Capacitance: 100 pF, 1 nF
Parameter(s)   Frequency: 1.592 kHz, 1 kHz
Status   Approved
  APMP.EM.RF- S1 Comparison of EMC antenna factor
1996
Comparison type, Field   Supplementary comparison in Electricity and Magnetism, Radio frequencies
Parameter(s)   Frequency: 30 MHz, 60 MHz, 120 MHz, 200 MHz, 400 MHz, 700 MHz and 1 GHz
Status   Approved
  APMP.EM.RF- S2 Comparison of RF power
1995 - 1998
Comparison type, Field   Supplementary comparison in Electricity and Magnetism, Radio frequencies
Parameter(s)   Frequency: 100 MHz, 1 GHz, 12 GHz and 17 GHz
Status   Approved
  APMP.RI(II)- S2.Ho- 166m Relative ionization chamber calibration factors to Ho-166m sealed source
2003 - 2004
Comparison type, Field   Supplementary comparison in Ionizing Radiation, Section II (Measurement of Radionuclides)
Status   Abandoned
  APMP.EM- S7 Comparison of capacitors
2003 - 2006
Comparison type, Field   Supplementary comparison in Electricity and Magnetism, Capacitance
Capacitance: 100 pF
Parameter(s)   Frequency: 1.592 kHz, 1 kHz
Status   Approved
  APMP.EM.RF- S3 Comparison of 50 ohm coaxial mismatches
2003 - 2004
Comparison type, Field   Supplementary comparison in Electricity and Magnetism, Radio frequencies
Reflection coefficient Sii for nominal VSWR 1.20, 1.50 and 2.00
Parameter(s)   Operating power level: smaller or equal to 10 mW (+10dBm)
Frequency: 50 MHz, 2.0 GHz, 10.0 GHz and 18.0 GHz
Status   Approved
  CCRI(II)- S6.I- 131 Measurement of radioactivity content of same solution
2006
Comparison type, Field   Supplementary comparison in Ionizing Radiation, Section II (Measurement of Radionuclides)
Radionuclide: I-131
Status   Report in progress, draft B
  APMP.AUV.A- S1 Comparison of sound calibrators
2008 - 2010
Comparison type, Field   Supplementary comparison in Acoustics, Ultrasound, and Vibration, Acoustics
Parameter(s)   Frequency: 31.5 Hz to 16000 Hz
Status   Approved
  SIM.M.P- S1 Pressure measurements (absolute mode)
2007 - 2008
Comparison type, Field   Supplementary comparison in Mass, Pressure
Pressure: 100 Pa to 70 kPa
Status   Abandoned
  SIM.L- S6 Gauge blocks by mechanical comparison
2008 - 2011
Comparison type, Field   Supplementary comparison in Length, Dimensional Metrology
Status   Approved
  CCRI(II)- S9 Measurement of the activity concentration of Cs-137 and K-40 in rice material
2011
Comparison type, Field   Supplementary comparison in Ionizing Radiation, Section II (Measurement of Radionuclides)
Status   Report in progress, draft A
  APMP.T- S7 Comparison of melting temperature of Co-C eutectic point cells
2010 - 2013
Comparison type, Field   Supplementary comparison in Thermometry, Thermocouples
Status   Approved
  APMP.L- S3 Gauge block by mechanical comparison
2006 - 2009
Comparison type, Field   Supplementary comparison in Length, Dimensional Metrology
Status   Approved
  APMP.EM- S8 Comparison on digital multimeter
2011 - 2013
Comparison type, Field   Supplementary comparison in Electricity and Magnetism, DC Voltage and Current
Status   Protocol complete
  APMP.RI(III)- S1 Comparison for the calibration of neutron ambient dose equivalent meters
2011 -2012
Comparison type, Field   Supplementary comparison in Ionizing Radiation, Section III (Neutron Measurements)
Status   Approved
  APMP.RI(I)- S3 Comparison of national air kerma standards for ISO 4037 Narrow and Wide Spectrum X-ray series in the range 30 kV to 300 kV
2013 - 2014
Comparison type, Field   Supplementary comparison in Ionizing Radiation, Section I (x and gamma rays, electrons)
Air kerma at protection level
Status   Measurements in progress
  EURAMET.QM- S5 Carbon dioxide in Nitrogen
2011 - 2012
Comparison type, Field   Supplementary comparison in Amount of Substance, Gases
Status   Approved
  APMP.M.P- S2 Pressure measurements
2005
Comparison type, Field   Supplementary comparison in Mass, Pressure
Status   Approved
  APMP.L- S7 Comparison of step height measurements
2014 - 2015
Comparison type, Field   Supplementary comparison in Length, Dimensional Metrology
Status   Measurements in progress