Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (12)
PHYSICS
Humidity (12)
Dew-point temperature (7)
Humidity (5)
GEOGRAPHIC LOCATION
APMP (12)
Japan (12)
Result of the search
Your query 'Japan' produced 12 results New search

 
Japan, NMIJ AIST (National Metrology Institute of Japan)
Complete CMCs in Thermometry for Japan (.PDF file)
Dew-point temperature. Dew-point hygrometer, -65 °C to -60 °C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in K: 0.5
Comparison
Pressure: ambient
Approved on 28 June 2007
Internal NMI service identifier: NMIJ/26-3
 
Dew-point temperature. Dew-point hygrometer, -60 °C to -50 °C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in K: 0.2
Comparison
Pressure: ambient
Approved on 28 June 2007
Internal NMI service identifier: NMIJ/26-3
 
Dew-point temperature. Dew-point hygrometer, -50 °C to -10 °C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in K: 0.08
Comparison
Pressure: ambient
Approved on 28 June 2007
Internal NMI service identifier: NMIJ/26-3
 
Dew-point temperature. Dew-point hygrometer, -10 °C to 0 °C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in K: 0.09
Comparison
Pressure: ambient
Approved on 28 June 2007
Internal NMI service identifier: NMIJ/26-1, NMIJ/26-2
 
Dew-point temperature. Dew-point hygrometer, 0 °C to 10 °C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in °C: 0.04
Comparison
Pressure: ambient
Approved on 16 March 2011
Internal NMI service identifier: NMIJ/26-1, NMIJ/26-2
 
Dew-point temperature. Dew-point hygrometer, 10 °C to 15 °C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in °C: 0.03
Comparison
Pressure: ambient
Approved on 16 March 2011
Internal NMI service identifier: NMIJ/26-1, NMIJ/26-2
 
Dew-point temperature. Dew-point hygrometer, 15 °C to 25 °C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in °C: 0.04
Comparison
Pressure: ambient
Approved on 16 March 2011
Internal NMI service identifier: NMIJ/26-1, NMIJ/26-2
 
Humidity. Trace moisture analyzer, 12 nmol/mol to 19 nmol/mol
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 7.6
Comparison
Approved on 05 June 2014
 
Humidity. Trace moisture analyzer, 19 nmol/mol to 49 nmol/mol
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 5.3
Comparison
Approved on 05 June 2014
 
Humidity. Trace moisture analyzer, 49 nmol/mol to 90 nmol/mol
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 3.4
Comparison
Approved on 05 June 2014
 
Humidity. Trace moisture analyzer, 90 nmol/mol to 500 nmol/mol
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 1.3
Comparison
Approved on 05 June 2014
 
Humidity. Trace moisture analyzer, 500 nmol/mol to 1400 nmol/mol
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.88
Comparison
Approved on 05 June 2014