Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs Chemistry (4)
CHEMICAL MATERIAL
polypropylene, polyethylene and polyvinyl chloride (4)
CHEMICAL ANALYTE
calcium
zinc
cadmium (1)
lead (1)
chromium (1)
arsenic (1)
GEOGRAPHIC LOCATION
APMP (4)
Thailand (4)
Result of the search
Your query 'NIMT' produced 4 results New search

Thailand, NIMT (National Institute of Metrology (Thailand))
Complete CMCs in Chemistry for Advanced materials for Thailand (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95%) in %
polypropylene, polyethylene and polyvinyl chloride cadmium 1 to 100 1.5 to 2.0
Mechanism(s) for measurement service delivery: Provision of reference values for both PT and RM samples
Uncertainty convention 1.
Approved on 19 June 2014.
Internal NMI service identifier: NIMT/12020-60210

Thailand, NIMT (National Institute of Metrology (Thailand))
Complete CMCs in Chemistry for Advanced materials for Thailand (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95%) in %
polypropylene, polyethylene and polyvinyl chloride chromium 25 to 500 2.5 to 3.0
Mechanism(s) for measurement service delivery: Provision of reference values for both PT and RM samples
Uncertainty convention 1.
Approved on 19 June 2014.
Internal NMI service identifier: NIMT/12020-60401

Thailand, NIMT (National Institute of Metrology (Thailand))
Complete CMCs in Chemistry for Advanced materials for Thailand (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95%) in %
polypropylene, polyethylene and polyvinyl chloride lead 1 to 1000 1.5 to 2.0
Mechanism(s) for measurement service delivery: Provision of reference values for both PT and RM samples
Uncertainty convention 1.
Approved on 19 June 2014.
Internal NMI service identifier: NIMT/12020-60604

Thailand, NIMT (National Institute of Metrology (Thailand))
Complete CMCs in Chemistry for Advanced materials for Thailand (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95%) in %
polypropylene, polyethylene and polyvinyl chloride arsenic 10 to 100 5.0 to 6.0
Mechanism(s) for measurement service delivery: Provision of reference values for PT/RM samples
Uncertainty convention 1.
Approved on 19 June 2014.
Internal NMI service identifier: NIMT/12021-60102