Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (6)
PHYSICS
AC voltage, current, and power (6)
AC current up to 100 A: sources (1)
AC voltage up to 1000 V: sources (1)
AC voltage up to 1000 V: meters (1)
AC-DC voltage transfer: AC-DC transfer difference at low voltages (1)
AC-DC voltage transfer: AC-DC transfer difference at medium voltages (1)
AC-DC voltage transfer: AC-DC transfer difference at higher voltages voltages (1)
GEOGRAPHIC LOCATION
APMP (6)
Thailand (6)
Result of the search
Your query 'NIMT' produced 6 results New search

 
Thailand, NIMT (National Institute of Metrology (Thailand))
Complete CMCs in Electricity and Magnetism for Thailand (.PDF file)
AC-DC voltage transfer: AC-DC transfer difference at low voltages. Thermal converters, AC-DC transfer standard, 0.01 V to 0.5 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µV/V: 13 to 250
AC-DC comparison
Frequency: 10 Hz to 1 MHz
Approved on 31 October 2016
Internal NMI service identifier: NIMT/5.1.1
Uncertainty table
 
AC-DC voltage transfer: AC-DC transfer difference at medium voltages. Thermal converters, AC-DC transfer standard, 0.6 V to 5 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µV/V: 13 to 32
AC-DC comparison
Frequency: 10 Hz to 1 MHz
Approved on 31 October 2016
Internal NMI service identifier: NIMT/5.1.2
Uncertainty table
 
AC-DC voltage transfer: AC-DC transfer difference at higher voltages voltages. Thermal converters, AC-DC transfer standard, 7 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µV/V: 13 to 81
AC-DC comparison
Frequency: 10 Hz to 1 MHz
Approved on 31 October 2016
Internal NMI service identifier: NIMT/5.1.3
Uncertainty table
 
AC voltage up to 1000 V: sources. Multifunction calibrator, 0.01 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µV/V: 20 to 580
AC-DC transfer standard
Frequency: 10 Hz to 1 MHz
Approved on 31 October 2016
Internal NMI service identifier: NIMT/5.2.1
Uncertainty table
 
AC voltage up to 1000 V: meters. AC voltmeter, multifunction transfer standard, AC measurement standard, 0.01 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µV/V: 16 to 580
AC-DC transfer standard
Frequency: 10 Hz to 1 MHz
Approved on 31 October 2016
Internal NMI service identifier: NIMT/5.2.2
Uncertainty table
 
AC current up to 100 A: sources. Multifunction calibrator, 0.0025 A to 20 A
Relative expanded uncertainty (k = 2, level of confidence 95 %) in mA/A: 0.069 to 0.202
AC-DC current transfer
Frequency: 10 Hz to 100 kHz
Approved on 31 October 2016
Internal NMI service identifier: NIMT/6.2.1
Uncertainty table