Your query 'Japan' produced 17 results New search

 
Japan, NMIJ AIST (National Metrology Institute of Japan)
Complete CMCs in Electricity and Magnetism for Japan (.PDF file)
AC voltage ratio: real component and imaginary component. Inductive voltage divider: imaginary component, -0.1 to 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.09E-08 to 1.5E-06
Comparison with the reference
Frequency: 50 Hz to 100 kHz
Voltage: 10 V, 100 V
Approved on 31 October 2016
Internal NMI service identifier: NMIJ/5.3.1b
Uncertainty table
 
AC current ratio: real component and imaginary component. Current comparator and current transformer: imaginary component, -0.001 rad to 0.001 rad
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in µrad: 0.21 to 77
Ampere-turn comparison
Frequency: 45 Hz to 4000 Hz
Primary current: 5 A to 50 A
Ratio: 1 to 1000
Approved on 31 October 2016
Internal NMI service identifier: NMIJ/6.3.1b
Uncertainty table
 
AC voltage ratio: real component and imaginary component. Inductive voltage divider: real component, -0.1 to 1
Absolute expanded uncertainty (k = 2, level of confidence 95 %): 0.04E-08 to 2.9E-06
Comparison with the reference
Frequency: 50 Hz to 100 kHz
Voltage: 10 V, 100 V
Approved on 31 October 2016
Internal NMI service identifier: NMIJ/5.3.1a
Uncertainty table
 
AC/DC voltage transfer: AC/DC transfer difference at lower voltage. AC-DC transfer standard, 0.01 V to 0.1 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µV/V: 10 to 130
Comparison
Frequency: 10 Hz to 100 kHz
Approved on 31 October 2016
Internal NMI service identifier: NMIJ/5.1.1
Uncertainty table
 
AC voltage. AC voltmeter, 1 V to 10 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µV/V: 9 to 150
Comparison
Frequency: 4 Hz to 100 kHz
Approved on 31 October 2016
Internal NMI service identifier: NMIJ/5.2.2
Uncertainty table
 
AC/DC current transfer. Thermal converter, 10 mA
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µA/A: 3 to 4
Comparison
Frequency: 40 Hz to 100 kHz
Approved on 31 October 2016
Internal NMI service identifier: NMIJ/6.1.1
Uncertainty table
 
AC current ratio: real component and imaginary component. Current comparator and current transformer: real component, 1 to 1000
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µA/A: 0.4 to 55
Ampere-turn comparison
Frequency: 45 Hz to 4000 Hz
Primary current: 5 A to 50 A
Ratio: 1 to 1000
Approved on 31 October 2016
Internal NMI service identifier: NMIJ/6.3.1a
Uncertainty table
 
Japan, JEMIC (Japan Electric Meters Inspection Corporation)
Complete CMCs in Electricity and Magnetism for Japan (.PDF file)
AC power and energy: single phase. Power converter, power meter, 0 W to 6000 W
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µW (VA)-1: 10 to 45
Direct comparison
Frequency : 45 Hz to 65 Hz
Power factor: any
Voltage: 50 V to 120 V
Current: 0.5 A to 50 A
Approved on 31 October 2016
Internal NMI service identifier: JEMIC/7.1.1
Uncertainty table
 
AC power and energy: single phase. Reactive power meter, 0 var to 6000 var
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µvar (VA)-1: 28 to 44
Direct comparison
Frequency : 45 Hz to 65 Hz
Power factor: any
Voltage: 50 V to 120 V
Current: 0.5 A to 50 A
Approved on 31 October 2016
Internal NMI service identifier: JEMIC/7.1.1a
Uncertainty table
 
AC power and energy: single phase. Energy meter, 200 J to 9000 J
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µJ/(VAs): 33 to 50
Direct comparison
Frequency : 45 Hz to 65 Hz
Power factor: 1 to 0.1 L/C
Voltage: 50 V to 120 V
Current: 2.5 A to 5 A
Approved on 31 October 2016
Internal NMI service identifier: JEMIC/7.1.1b
Uncertainty table
 
AC power and energy: single phase. Reactive energy meter, 200 var to 9000 var
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µvar s (VAs)-1: 33 to 50
Direct comparison
Frequency : 45 Hz to 65 Hz
Power factor: 0 C to 0.995 C, 0 L to 0.995 L
Voltage: 50 V to 120 V
Current: 2.5 A to 5 A
Approved on 31 October 2016
Internal NMI service identifier: JEMIC/7.1.1c
Uncertainty table
 
AC power and energy: three phase. Power meter, 0 W to 1800 W
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µW (VA)-1: 26 to 35
Direct comparison
Frequency : 45 Hz to 65 Hz
Power factor: any
Voltage: 50 V to 120 V
Current: 2.5 A to 5 A
Approved on 31 October 2016
Internal NMI service identifier: JEMIC/7.1.3a
Uncertainty table
 
AC power and energy: three phase. Reactive power meter, 0 var to 1800 var
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µvar (VA)-1: 26 to 35
Direct comparison
Frequency : 45 Hz to 65 Hz
Power factor: any
Voltage: 50 V to 120 V
Current: 2.5 A to 5 A
Approved on 31 October 2016
Internal NMI service identifier: JEMIC/7.1.3b
Uncertainty table
 
Japan, NMIJ AIST (National Metrology Institute of Japan)
Complete CMCs in Electricity and Magnetism for Japan (.PDF file)
AC/DC voltage transfer: AC/DC transfer difference at medium voltage. Thermal converter, 0.1 V to 5 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µV/V: 2 to 35
Comparison
Frequency: 10 Hz to 1 MHz
Approved on 31 October 2016
Internal NMI service identifier: NMIJ/5.1.2
Uncertainty table
 
AC/DC voltage transfer: AC/DC transfer difference at higher voltage. Thermal converter with range extender, 20 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µV/V: 5 to 48
Comparison
Frequency: 10 Hz to 1 MHz
Approved on 31 October 2016
Internal NMI service identifier: NMIJ/5.1.3
Uncertainty table
 
Japan, JEMIC (Japan Electric Meters Inspection Corporation)
Complete CMCs in Electricity and Magnetism for Japan (.PDF file)
AC power and energy: three phase. Energy meter, 400 J to 27000 J
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µJ/(VAs): 32 to 40
Direct comparison
Frequency : 45 Hz to 65 Hz
Power factor: 1 L/C to 0.1 L/C
Voltage: 50 V to 120 V
Current: 2.5 A to 5 A
Approved on 31 October 2016
Internal NMI service identifier: JEMIC/7.1.3c
Uncertainty table
 
AC power and energy: three phase. Reactive energy meter, 400 var to 27000 var
Relative expanded uncertainty (k = 2, level of confidence 95 %) in µvar s (VAs)-1: 32 to 40
Direct comparison
Frequency : 45 Hz to 65 Hz
Power factor: 0 C to 0.995 C, 0 L to 0.995 L
Voltage: 50 V to 120 V
Current: 2.5 A to 5 A
Approved on 31 October 2016
Internal NMI service identifier: JEMIC/7.1.3d
Uncertainty table