Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (5)
PHYSICS
Fluid flow (5)
Liquid flowing quantity: mass or volume (5)
GEOGRAPHIC LOCATION
EURAMET (5)
United Kingdom (5)
Result of the search
Your query 'United Kingdom' produced 5 results New search

 
United Kingdom, TUVNEL (TUVNEL)
Complete CMCs in Mass and related quantities for United Kingdom (.PDF file)
Liquid flowing quantity: mass or volume. Any flow measurement instrument or flow device, 0.002 L/min to 5 L/min
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.05
Pulsed, electrical, digital and optical outputs; various methods
Fluid: kerosine, gas-oil, velocite, water, any safe liquid
Viscosity: up to 30 cSt
Temperature: ambient
Pressure: 0 MPa to 0.5 MPa
Approved on 15 October 2013
Internal NMI service identifier: UK1
 
Liquid flowing quantity: mass or volume. Any flow measurement instrument or flow device, 0.04 L/s to 100 L/s
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.03
Pulsed, electrical, digital and optical outputs; various methods
Fluid: kerosine, gas-oil, mineral oils
Viscosity: 2.2 cSt to 30 cSt
Temperature: 5 °C to 50 °C
Pressure: 0 MPa to 0.8 MPa
Pipe up to 200 mm
Approved on 15 October 2013
Internal NMI service identifier: UK2
 
Liquid flowing quantity: mass or volume. Any flow measurement instrument or flow device, 0.04 L/s to 100 L/s
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.05
Pulsed, electrical, digital and optical outputs; various methods
Fluid: heavy oil
Viscosity: 30 cSt and 500 cSt
Temperature: 5 °C to 50 °C
Pressure: 0 MPa to 0.8 MPa
Pipe up to 200 mm
Approved on 15 October 2013
Internal NMI service identifier: UK3
 
Liquid flowing quantity: mass or volume. Any flow measurement instrument or flow device, 0.04 L/s to 200 L/s
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.08
Pulsed, electrical, digital and optical outputs; various methods
Fluid: kerosine, gas-oil, mineral oils
Viscosity: 2.2 cSt to 30 cSt
Temperature: 5 °C to 50 °C
Pressure: 0 MPa to 0.8 MPa
Pipe up to 200 mm
Approved on 15 October 2013
Internal NMI service identifier: UK4
 
Liquid flowing quantity: mass or volume. Any flow measurement instrument or flow device, 0.04 L/s to 150 L/s
Relative expanded uncertainty (k = 2, level of confidence 95 %) in %: 0.25
Pulsed, electrical, digital and optical outputs; various methods
Fluid: heavy oil
Viscosity: 30 cSt to 500 cSt
Temperature: 5 °C to 50 °C
Pressure: 0 MPa to 0.8 MPa
Pipe up to 200 mm
Approved on 15 October 2013
Internal NMI service identifier: UK5