Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in mol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
methane carbon dioxide 5E-02 to 7E-02 1.5 5E-02 to 7E-02 1.5
Mechanism(s) for measurement service delivery: CRM 112-01-6871P
Approved on 24 January 2006.
Internal NMI service identifier: KRISS/KG075
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in mol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen carbon dioxide 15E-02 to 20E-02 1.5 15E-02 to 20E-02 1.5
Mechanism(s) for measurement service delivery: CRM 112-01-2981P
Internal NMI service identifier: KRISS/KG081
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
hydrogen carbon dioxide 0.1E-06 to 100E-06 30 to 2
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: KRISS/KG131
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
oxygen carbon dioxide 0.1E-06 to 100E-06 30 to 2
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: KRISS/KG132
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
nitrogen carbon dioxide 0.1E-06 to 100E-06 30 to 2
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: KRISS/KG133
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
helium carbon dioxide 0.1E-06 to 100E-06 30 to 2
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: KRISS/KG134
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
argon carbon dioxide 0.1E-06 to 100E-06 30 to 2
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: KRISS/KG135
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in mol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen carbon dioxide 0.1 to 0.15 1.5 0.1 to 0.15 1.5
Mechanism(s) for measurement service delivery: CRM 112-03-020
Internal NMI service identifier: KRISS/KG095
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in mol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
helium carbon dioxide 10E-06 to 1000E-06 3 to 0.5 10E-06 to 1000E-06 3 to 0.5
Mechanism(s) for measurement service delivery: CRM 112-01-1821N
Internal NMI service identifier: KRISS/KG041
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in mol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
methane carbon dioxide 0.1E-02 to 5E-02 0.5 to 1.0 0.1E-02 to 5E-02 0.5 to 1.0
Mechanism(s) for measurement service delivery: CRM 112-01-6991O
Internal NMI service identifier: KRISS/KG085
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in mol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
synthetic natural gas carbon dioxide 0.002 to 0.05 1 to 2 0.002 to 0.05 1 to 2
Mechanism(s) for measurement service delivery: CRM 112-01-911, 912, 913
Internal NMI service identifier: KRISS/KG011
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in µmol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen carbon dioxide 0.02 to 10 100 to 0.02 0.02 to 10 100 to 0.02
Mechanism(s) for measurement service delivery: CRM 112-01-2141N
Uncertainty convention 2.
Approved on 30 August 2017.
Internal NMI service identifier: KRISS/KG027

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in µmol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen carbon dioxide 10 to 500000 0.02 10 to 500000 0.02
Mechanism(s) for measurement service delivery: CRM 112-01-2141O
Uncertainty convention 2.
Approved on 30 August 2017.
Internal NMI service identifier: KRISS/KG028

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in µmol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen carbon dioxide 10 to 500000 0.3 10 to 500000 0.3
Mechanism(s) for measurement service delivery: CRM 112-03-019
Internal NMI service identifier: KRISS/KG097
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in µmol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
air carbon dioxide 10 to 500000 0.02 10 to 500000 0.02
Mechanism(s) for measurement service delivery: CRM 112-03-164A
Uncertainty convention 2.
Approved on 30 August 2017.
Internal NMI service identifier: KRISS/KG197

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in µmol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen carbon dioxide 10 to 500000 0.3 10 to 500000 0.3
Mechanism(s) for measurement service delivery: CRM 112-03-007
Internal NMI service identifier: KRISS/KG013
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in µmol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen carbon dioxide 10 to 500000 0.3 10 to 500000 0.3
Mechanism(s) for measurement service delivery: CRM 112-01-2821P
Internal NMI service identifier: KRISS/KG042
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in µmol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen carbon dioxide 10 to 500000 0.3 10 to 500000 0.3
Mechanism(s) for measurement service delivery: CRM 112-01-2824P
Internal NMI service identifier: KRISS/KG044
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in µmol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen carbon dioxide 10 to 500000 0.3 10 to 500000 0.3
Mechanism(s) for measurement service delivery: CRM 112-1-2852P
Internal NMI service identifier: KRISS/KG047
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in µmol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in µmol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen carbon dioxide 10 to 500000 0.3 10 to 500000 0.3
Mechanism(s) for measurement service delivery: CRM 112-1-2851P
Internal NMI service identifier: KRISS/KG048
This displays only one part of a multi-component CMC.